background image

hidden general setting interface; (3) 

Call the high temperature setting interface

long press the selection key in the main interface to call Hidden high temperature 

alarm setting interface. 

 

(4) RES 

In  normal  operation,  the  RES  key  has  2  functions  in  normal  operation.  (1) 

Switching function

: In the shutdown state, press and hold the RES button for more 

than 1 second to start the system; in the startup state, press and hold the RES button 

for more than 3 seconds, then the system shuts down; (2) 

Return function

: in the 

normal In the setting operation, press and hold the key for about 0.5s to return and 

reset, clear the alarm number and the number of people passing by.

 

Basic operation

 

1.

 

Power on 

In the shutdown state, long press the "RES" button for more than 1 second, the 

system boot, enter the main interface. 

2.

 

Power off 

In  the  power  on,  long  press  the  "RES"  button  for  more  than  3  seconds,  the 

system shuts down. 

3.

 

Reset 

Press the "RES" key for 0.5 seconds to 3 seconds in any interface, the system 

reset,  the  interface  returns  to  the  initial  interface  when  the  boot,  and  the 

number of alarm and pass number will be clear. 

Function parameter setting

 

 

1.

 

Password Modify: 

1)

 

Enter the correct password 1234 or Advanced Password 8888 Press the "ENT" 

button and press "SEL" to enter the password modification menu. 

2)

 

Presss  "ADJ"  key  to  select  the  password  number,  "SEL"  key  to  change  the 

selected  bit  number,  until  the  4-digit  password  setting  completely,  press  the 

"ENT"  button  2  times,  password  modification  is  successful;  enter  the 

"sensitivity adjustment" menu. 

 
2.

 

Sensitivity Adjustment

 

Press "ENT" key to select the sensitivity position, "ADJ" key and "SEL" key 

to change the selected bit number. 

Note: the sensitivity is 0 ~ 299 adjustable, the greater the value, the higher 

the sensitivity of the region; the smaller the value, the lower the sensitivity 

of the area. 

 

3.

 

Frequency Setting:

 

Long Press the "SEL" key to enter the "frequency adjustment" interface, through 

the  "SEL"  key  /  "ADJ"  key  to  adjust  the  frequency,  press  the  "ENT"  button  to 

confirm. 

 

4.

 

Alarm temperature Setting: 

1)

 

Long Press the "ADJ" key, the first line displays the temperature XX-X. 

2)

 

Press the "SEL" key / "ADJ" key to adjust. 

3)

 

Enter

ENT

  key to confirm. 

Adjustment

 

 

1.

 

WTMD  should  be  fixed  in  stable  station.  Distinguish  way  as 
followed: 

Summary of Contents for Walk-through

Page 1: ...Please Contact Us At 800 730 8382 For Inquiries Related To Your Interest In Placing A Bulk Order For Hospitals Institutions Schools Government Commercial Buildings ETC Disclaimer This detection device...

Page 2: ...hould obey internal time is above 1 second 7 Do not knock the machine when operating for avoid emitting false signal even damage 8 Use soft damp clothing or dipped alcohol clothing to clean your equip...

Page 3: ...nd stable 3 Composite circuit layout The equipment has a counter that registers the number of persons passed through and the number of alarms The counter uses Photoelectric Beam Detector which can res...

Page 4: ...ircuit high power switch inverter welding machine engine motor machine daylight lamp with rectifier 5 Position WTMDs side by side When posit WTMDs side by side the device will be influenced each other...

Page 5: ...2 Digitron Display It is a LED display Simple easy to operate 3 Keyboard operation 1 ENT The ENT key has 3 functions in normal operation 1 Confirmation function After entering the power on password o...

Page 6: ...initial interface when the boot and the number of alarm and pass number will be clear Function parameter setting 1 Password Modify 1 Enter the correct password 1234 or Advanced Password 8888 Press the...

Page 7: ...ple who walk through the gate carried metal objects For pointing the hidden place you can use Hand Held Metal Detector to scan the alarm zone of the body 6 Some special occasions need ladies do not wa...

Page 8: ...her it is 13V 4 If it is 13V means it is normal then pls use the multimeter to check voltage of finger 1 of the U12 TL062 on the Main Board the normal volts D C is 0 7 0 9V 5 Different temperature dif...

Page 9: ...ll 50mmSteel Ball Packing OK Product OK Verify Checker List of Items User Manual 8 pcs of Screw Power Cord 4 pcs Fixing Screw 5mm Allen Key 1 pcs Remote Controller Test Controller Quality Inspector Wa...

Page 10: ...For Inquiries Related To Your Interest In Placing A Bulk Order For Hospitals Institutions Schools Government Commercial Buildings ETC Disclaimer This detection device is not a medical device and cann...

Reviews: