O-ring Face Seal Tightening Torque
Tubeline O.D.
Thread Size
N•m (ft-lb)
1/4”
9/16” - 18
13 (18)
3/8”
11/16” - 16
22 (30)
1/2”
13/16” - 16
40 (54)
5/8”
1” - 14
60 (81)
3/4”
1-3/16” - 12
84 (114)
7/8”
1-3/16” - 12
98 (133)
1”
1-7/16” - 12
118 (160)
1-1/4”
1-11/16” - 12
154 (209)
1-1/2”
2” - 12
163 (221)
When the fitting is tightened, you can feel when
the fitting is tight to eliminate leakage caused by
under or over torqued fittings. Use petroleum jelly
to hold the O-ring in position until the fittings are
assembled.
Flare Fitting
Flare Fitting Tightening Torque
Tubeline O.D.
Thread Size
N • m (ft-lb)
1/4”
7/16” - 20
13 (18)
5/16”
1/2” - 20
17 (23)
3/8”
9/16” - 18
22 (30)
1/2”
3/4” - 16
40 (54)
5/8”
7/8” - 14
60 (81)
3/4”
1-1/16” - 12
84 (114)
7/8”
1-3/16” - 12
98 (133)
1”
1-5/16” - 12
118 (160)
1-1/4”
1-5/8” - 12
154 (209)
1-1/2”
1-7/8” - 12
163 (221)
2”
2-1/2” - 12
252 (342)
Tighten until the nut makes contact with the
seat. Use the chart [Figure 57] to find the correct
tightness needed.
Port Seal (O-Ring Boss) Fitting
Port Seal And O-ring Boss Tightening Torque
Tubeline O.D.
Thread Size
N•m (ft-lb)
1/4”
7/16” - 20
13 (18)
3/8”
9/16” - 18
22 (30)
1/2”
3/4” -1 6
40 (54)
5/8”
7/8” - 14
60 (81)
3/4”
1-1/16” - 12
84 (114)
7/8”
1-3/16” - 12
98 (133)
1”
1-5/16” - 12
118 (160)
1-1/8”
1-7/16” - 12
154 (209)
1-1/4”
1-5/8” - 12
163 (221)
Note:
Port seal and nut, washer and O-ring (O-ring
Boss) fittings use the same tightening
torque valve chart [Figure 58].
If a torque wrench cannot be used, use the
following method.
Tighten the nut until it just makes metal to metal
contact, you can feel the resistance.
Tighten the nut with a wrench no more than one
hex flat maximum.
Do not over tighten the port seal fitting.
Note:
If a torque wrench cannot be used, use
the hex flat tightening method as an
approximate guideline.
Note:
Port seal fittings are not recommended in
all applications. Use O-ring boss fittings in
these applications.
Tubelines And Hoses
Replace any tubelines that are bent or flattened.
They will restrict flow, which will slow hydraulic
action and cause heat.
Replace hoses which show signs of wear, damage
or weather cracked rubber.
Always use two wrenches when loosening and
tightening hose or tubeline fittings.
Summary of Contents for 1342
Page 1: ...082020 FK422 OPERATOR AND PARTS MANUAL 13 CONVENTIONAL AUGER Models 1342 1352 1362 ...
Page 2: ......
Page 4: ... 13 Conventional Auger ii ...
Page 6: ... 13 Conventional Auger 2 ...
Page 8: ...Warranty Registration Form 13 Conventional Auger 4 ...
Page 10: ...Introduction 13 Conventional Auger 6 ...
Page 13: ...Introduction 13 Conventional Auger 9 BRIDGING TRUSS CABLE 52 FT MODEL 62 FT MODEL ...
Page 14: ...Introduction 13 Conventional Auger 10 ...
Page 16: ...Safety 13 Conventional Auger 12 ...
Page 23: ...Safety 13 Conventional Auger 19 ...
Page 84: ...Operation 13 Conventional Auger 80 ...
Page 98: ...Maintenance 13 Conventional Auger 94 ...
Page 108: ...Maintenance 13 Conventional Auger 104 ...
Page 110: ...Parts Identification 13 Conventional Auger 106 AXLE STUB W HUB 175 HUB 176 WHEEL ANDTIRE 177 ...
Page 111: ...Parts Identification 13 Conventional Auger 107 ...
Page 182: ...Parts Identification 13 Conventional Auger 178 ...
Page 184: ...Specifications 13 Conventional Auger 180 ...
Page 186: ...Specifications 13 Conventional Auger 182 HARDWARETORQUE VALUES Metric Chart ...
Page 187: ...Specifications 13 Conventional Auger 183 Imperial Chart ...
Page 190: ...Warranty 13 Conventional Auger 186 ...
Page 193: ......