6
W
ITHOUT
C
OAX
*
W
ITH
C
OAX
(GB- '99)
*
M
ODY *
E
RRE
P/R
*
P
ROJECT
*
P
UNTO
V
IRGOLA *
S
LIM
PT5860. Two-colour reflex monitor with au-
dio-video privacy, electronic microphone, dif-
ferentiated double electronic ringing sounds
(modulated and continuous note) and termi-
nal board for the connection to the wall-
bracket. With two buttons, one for control
switch ON and one for door lock release, and
6 supplementary buttons, that can be added
for additional services such as: control switch
ON, intercommunicating calls, stair lights,
door lock release, etc. The buttons are in-
cluded in the kit of the monitor. The maximum
acceptable current to the button terminals is
60mA. For higher currents use relay unit
art.1471.
It can be installed on the wall by using the
wall-bracket art.WB5600 or WB5660. For
particular needs it is possible to separate the
common of the buttons labeled P4, P5 and P6
by cutting the W1 jumper on the wall-bracket.
The buttons have the 2C terminal in common.
In this case the maximum acceptable current
to the three buttons is 0.5A.
PT5860W. This model has the same features
as the previous one, but with a white finish.
Technical data
Power Supply
18÷24Vdc
Operating current
0.6A
Video tube
4.5" - 90°
Television standard
625 lines
Horizontal frequency
15625Hz
Vertical frequency
50Hz
Bandwidth
>5MHz
Video signal on 75
Ω
0.8÷1.5Vpp
Starting up time
5÷7 sec.
Operating temperature
0°÷+50°C
Max. permissible humidity
90%RH
Project series
Measures for the installation of the wall bracket
WB5600 or WB5660 to the wall, and recommended
height from the floor.
Installation of the wall bracket WB5600 or WB5660 to the
wall, by means of expansion plugs.
Wall-brackets for the PT5860 and PT5860W monitors.
WB5660. The wall bracket includes 2 termi-
nal boards for connection to the system, it is
to be used when installing monitors with extra
buttons and/or 2 differentiated bells.
Located on the wall-bracket terminal board is
a J1 jumper positioned for the intercommuni-
cating service (position A).
By using the PT5860 and PT5860W monitors
with multi-way systems without the intercom-
municating service, the audio privacy can be
restored by positioning the jumper J1 in B.
Terminals
The terminals from 1 to 14 have the same func-
tions and characteristics as the previous model.
V
Activation input for digital systems
X1 AC power supply input 13Vac-0.35A
X2 Intercommunicating call input (ground com-
mand)
1C Common for P1, P2 and P3 buttons
2C Common for P4, P5 and P6 buttons
P1÷P6 Service buttons - max 60mA
WB5600. The wall bracket includes a
terminal board for connection to the
system, it is to be used when installing
2 - button monitors (control switch-ON
and door lock release), with a one call.
Terminals
1
Video signal input 0.8÷1.5Vpp
2
General ground
3
Video ground
4
Control switch ON - button
8
Positive power supply output for video
floor distributors 12Vdc
9
Door lock release - button
10 Call from the door station (180mA)
11 Audio ground
12 Microphone output
13 Speaker and automatic cancel
14 Positive power supply input 18÷24Vdc
V
Not connected
MONITORS