W
ITHOUT
C
OAX
*
W
ITH
C
OAX
34
(GB- '99)
MULTI-WAY COMBINED INTERCOM VIDEO-INTERCOM SYSTEM WITH AUDIO-VIDEO PRIVACY
Diagram ref. Q.ty
Article
Description
VC
...
PT 5160 + WB 5100
Monitor FLAT + wall bracket
PT 5660 + WB 5600 + 1283
M wall b back box
PT 5860 + WB 5600
Monitor wall bracket
PV 1260 + 1283
M wall b back box
PV 2160 + WB 2100
Monitor FLAT + wall bracket
CT
...
PT510
1 button intercom
PT520
2 button intercom
PV260
2 button intercom
SC
...
SM50
Conversation privacy module
DV
...
DV2-4
Video floor distributors
AL
1
1281
Stabilized power supply
TR
1
1382
Audio-Video Timer
PA
1
**
Door release button
SE
1
**
Electric door lock (12Vac-1A)
External door station
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
1
MD40
MD40
Camera module
PB
...
MD72-73-74
MD72-73-74
Module frames and with back box
1
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
1
MD82 ÷ 812
MD82 ÷ 812
Hood covers
1
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters
PE
1
MD30
MD30
Electric door speaker
ErreP/R series (see pages 21, 22 for the composition)
UR
1
1385R
Camera unit
PB
1
RP...
Push-button panel
...
R...
Push-button panel
1
290R/2 ÷ 290R/38
Rain shelters
PE
1
337C
Electric door speaker
... According to the number of users.
* The protective shelters are to be used instead
of back boxes and decorative shields.
** Articles not provided by ACI Farfisa.
Si 5051
Working instructions
It is similar to the basic system described on
page 28, but with the following variations:
- from the intercom the user has about 40
seconds to answer by lifting the handset and
therefore can speak for an unlimited time with
video privacy towards the other users. By
replacing the handset the system shuts itself
OFF.
Note
- The A and F terminals of article 1382 can be
connected to a maximum of 8 lamps (24V-3W).
If this number is exceeded, one or more 12V
transformers and an proper power will be re-
quired (type PRS210).
- If the control switch ON is needed connect
terminal 4 of the timer (dashed line).
- If secrecy of conversation is not needed, all
the systems 4+1 Farfisa can be used.
- For the cross section of the wires see the
table on page 26.
- To connect the coaxial cable see pages 26
and 27.
Notes for systems of Project series:
- to cut the jumper W1 that links the
terminals 3 and 7.
- move the connection of the buzzer
from terminal 3 to 7.
- make the connection between terminal
7 of the intercom and the - (minus) of the
privacy module.
Cut the resistance R1 in all of the pri-
vacy modules.
Notes for systems of PV260, PV260W
intercoms:
- remove the jumper that links termi-
nals 3 and 7.
- move the connection of the buzzer
from terminal 3 to 7.
- make the connection between terminal
7 of the intercom and the - (minus) of the
privacy module.
Cut the resistance R1 in all of the pri-
vacy modules.
Connection of secrecy module to the terminal board of the system
*
M
ODY
*
E
RRE
P/R
*
P
ROJECT
*
P
UNT
O
V
IRGOLA
*
S
LIM
Multi-way systems