20
W
ITHOUT
C
OAX
*
W
ITH
C
OAX
(GB- '99)
FC52.
Access control keypad with 12 digits and 2
relays for lock release. 4 programmable ac-
cess codes for each relay. Programmable
door opening time from 1 up 99 sec. for each
relay (or bistable operation of one relay).
Acoustic confirmation for entered keys, ac-
cepted programmation and for wrong codes.
Power supply: 13VAC/DC-0.1A.
Dati tecnici
Power supply:
12Vac/dc ±10%
Stand-by current:
0.015A
Maximum current consumption: 0.1A
Contact ratings:
12VAC-5A.
Numbers of codes for relais 1: 4
Numbers of codes for relais 2: 4 or direct
activation
Activation time for each relay:
from 1 to 99 sec.
(or bistable relay 1)
Operating temperature:
0° ÷ +40°C
Maximum permissible humidity:
85% RH
Terminals
1
normally closed contact of relais 2
2
normally open contact of relais 2
3
commun contact of relais 2
4
normally closed contact of relais 1
5
normally open contact of relais 1
6
commun contact of relais 1
7
ground or alternate voltage input
8
positive or alternate voltage input
Example of composition
MODY series
CAMERAS
Terminals
V
video signal output
M
ground
F
not connected
H
positive power supply input 21Vdc
MD 40C Colour.
This module includes:
- solid-state camera (CCD) with auto iris,
5.6mm fixed optics and 6 infrared-ray LED’s.
- front plate in anodized aluminium, with break-
proof transparent screen.
Note: it is to be applied to all video installation
diagrams with coaxial cable.
Technical data
Power supply
21±3Vdc
Operating current
0.4A
Video signal on 75
Ω
1Vpp
Minimum illumination
2.5 lux
Sensor
CCD 1/3"
Gamma characteristic
0.45
White balance
auto
Horizontal frequency
15625Hz
Vertical frequency
50Hz
Lens
5.6mm; F4
Adjustable focus
0.6m ÷
∞
Standard segnale video
CCIR
Operating temperature
-10°÷+40°
Maximum permissible humidity
80%RH
AMPLIFIED DOOR STATIONS
MD 100. 1 button module.
It can be applied to all systems 4+1, intercom-
municating systems, and video-intercom sys-
tems with coaxial cable.
It includes electric door speaker, amplified in
the two channels, volume control of “receiver”,
“call” button and front plate in anodized alu-
minium. It can replace in many installations
module MD11 and MD30, using all the other
accessories of the Mody series.
For module installation, see the diagram on
page 32.
MD 200. 2 buttons module.
Terminals
-
ground
supply 13Vac-60mA
1
receiver
2
transmitter
C
call buttons common
call buttons
name-plate lamp (24V-70mA)
MD 40.
This module includes:
- solid-state camera (CCD) with auto iris,
3.6mm fixed optics and 6 infrared-ray LED’s.
- front plate in anodized aluminium, with break-
proof transparent screen.
Technical data
Power supply
21±3Vdc
Operating current
0.2A
Video signal on 75
Ω
1Vpp
Minimum illumination
2 lux
Sensor
CCD 1/3"
Pixel number
291000
Horizontal frequency
15625Hz
Vertical frequency
50Hz
Lens
3.6mm; F5
Adjustable focus
0.1m ÷
∞
Opening of auto-iris
Operating temperature
-10°÷+40°
Maximum permissible humidity
80%RH
1 Lamp terminals
2 Button terminal board
3 Call buttons common
4 Stair light button terminals
5 External volume adjustment
6 Terminal board for audio/powering
2
3
4
5
6
1
ACCESS CONTROL KEYPAD
*
M
ODY
*
E
RRE
P/R
*
P
ROJECT *
P
UNTO
V
IRGOLA *
S
LIM
PUSH-BUTTON PANELS
Relay 1
Relay 2
Relais 1
Relais 2
13Vac
13Vdc