![Faraone ZP8 Use And Maintenance Instructions Download Page 64](http://html1.mh-extra.com/html/faraone/zp8/zp8_use-and-maintenance-instructions_3420331064.webp)
USE AND MAINTENANCE MANUAL - SECTION 6
AERIAL PLATFORM ZP
– Rev. 05_2018
Page 6-1
SECTION 6. DAILY INSPECTION
Start the full inspection from point (a), as set out in the following list. Proceed
around the machine checking all listed conditions in sequence.
ATTENTION
TO AVOID ANY INJURIES, ENSURE THAT THE MACHINE POWER SUPPLY IS
SWITCHED OFF DURING "FULL INSPECTION".
DO NOT USE THE MACHINE BEFORE REPAIRING ALL FAULTS.
DO NOT FAIL TO CARRY OUT A VISUAL INSPECTION OF THE LOWER PART
OF THE BASE FRAME. ENSURE THE AREA IS CLEAR OF OBJECTS OR
DEBRIS THAT MIGHT CAUSE SERIOUS DAMAGE TO THE MACHINE.
NOTE FOR INSPECTION: besides complying with the above criteria, ensure
for each component that all parts are present, securely fixed and not loose
and that there are no visible damage, leaks or signs of excessive wear.
(a) Drive wheels/free wheels and swivel castors
Check there is no debris on the wheels or around them;
(b) Base frame
Ensure there are no loose wires or cables hanging underneath the base,
check for any dents, rupture or cracks on the profiles;
(c) Manual descent control valve
– See note pertaining to functional
check;
(d) Stabilisers (if present)
Check for dents on the aluminium profiles, breaks or cracks, and check
operation of the adjustable stabiliser feet;
(e) Motor/pump/tank unit
No conspicuous hydraulic leak, hydraulic oil filling level at the "full" line;
Summary of Contents for ZP8
Page 84: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ZP Rev 05_2018 Page 9 7 ...
Page 86: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ZP Rev 05_2018 Page 9 9 ...
Page 88: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ZP Rev 05_2018 Page 9 11 ...
Page 90: ...NOTES ...
Page 91: ......