USE AND MAINTENANCE MANUAL - SECTION 8
ELEVAH 40 MOVE / 40 B AERIAL PLATFORM
– Rev. 12_2021
Page 8-6
CHANGING THE TORQUE REDUCER GREASE
(
ELEVAH 40 MOVE
)
CAUTION
PAY ATTENTION BECAUSE DURING NORMAL OPERATION THE SURFACES ARE HOT
The body of the reducer contains a quantity of semi-fluid grease (AGIP GR MU/EP1 or equivalent)
sufficient for over 1,000 hours of operation.
The grease must be changed during the general overhaul of the drive wheels.
CAUTION
DISPOSE OF THE REPLACED GREASE IN ACCORDANCE WITH THE LAWS IN FORCE.
REPLACING THE EXTENSION SLIDING PADS
Each part of the lifting column, called extension, slides over the other by means of nylon pads.
With regular machine use, these pads could be worn and this could cause direct rubbing of the
extensions, thereby compromising machine efficiency.
As soon as you begin noticing the extensions rubbing directly, it is mandatory to stop the machine
and replace the pads.
For this, it is advisable to contact Faraone S.p.A. or an authorised maintenance centre.
The following procedure must be strictly complied with to replace the pads.
Removing worn pads
1. Lift the machine with a forklift and unscrew the fixing nut found under the machine that connects
the cage unit to the hydraulic cylinder and reposition the machine on the ground;