USE AND MAINTENANCE MANUAL - SECTION 6
ELEVAH 40 MOVE / 40 B AERIAL PLATFORM
– Rev. 12_2021
Page 6-1
SECTION 6.
DAILY INSPECTION
Start the full inspection from point (a), as set out in the following list. Proceed around the machine
checking all listed conditions in sequence.
CAUTION
TO PREVENT ANY INJURIES, ENSURE THAT THE MACHINE POWER SUPPLY IS SWITCHED
OFF DURING THE “FULL INSPECTION”.
DO NOT USE THE MACHINE BEFORE REPAIRING ALL FAULTS.
DO NOT FAIL TO CARRY OUT A VISUAL INSPECTION OF THE LOWER PART OF THE BASE
FRAME. ENSURE THE AREA IS CLEAR OF OBJECTS OR DEBRIS THAT MIGHT CAUSE
SERIOUS DAMAGE TO THE MACHINE.
NOTE FOR INSPECTION:
besides complying with the above criteria, ensure for each component
that all parts are in place, securely fixed and not loose, and that there is no visible damage, leaks or
signs of excessive wear.
a) Drive wheels/idler wheels and swivel wheels:
Check there is no debris attached to the wheels
or around them;
b)
Base frame:
Ensure there are no loose wires or cables hanging underneath the base, check for
any dents, breaks or cracks on the profiles;
c) Manual descent control valve
: see note pertaining to functional check;
d) Motor/pump/tank unit:
No conspicuous hydraulic leak, hydraulic oil filling level at the "full" line;
e) Batteries
:
Charge them as required;
f) Cage unit and entrance doors:
Correct blocking of the cage and entrance doors operating
correctly;
g) Cage control console:
Controls secured, legible signs, emergency stop switch in the reset
position for operation and legible control signs;
h) Extensible
structure unit:
Structure profiles, sliding inserts that can slide freely.
i) Level bubbles
:
Check the integrity of the spirit levels on the base frame.
j) Parking system (ELEVAH 40 B):
Check and verify that the parking system functions correctly.
CAUTION
DO NOT USE THE MACHINE BEFORE REPAIRING ALL DISCOVERED FAULTS /
MALFUNCTIONS