USE AND MAINTENANCE MANUAL - SECTION 4
ELEVAH 40 MOVE / 40 B AERIAL PLATFORM
– Rev. 12_2021
Page 4-9
Error No.
Error description
Error cause
Solution
ALARM 1
Drive current protection
Current peak above the drive limit
Restart the machine
ALARM 2
Motor current protection
Maximum set motor current exceeded
Restart the machine
ALARM 5
Accelerator error
Accelerator potentiometer disconnected
or calibrated incorrectly
Contact assistance
ALARM 8
Maximum battery
Battery voltage over the maximum
Restart the machine
ALARM 9
Flat battery
Battery voltage over the minimum
Charge
ALARM 12
CANbus Error
No communication between the devices
connected via CANbus
Contact assistance
ALARM 13
Controller error
Motor connected to the start, movement
not allowed
Contact assistance
ALARM 14
Overheating
Board temperature over the limit
Restart the machine
ALARM 17
Control unit error
Internal checks
Contact assistance
ALARM 19
Current threshold
exceeded
Current limit time exceeded.
Restart the machine
ALARM 49
Electric brake error
Error in the detection of the electric
brake input when starting the machine
Contact Assistance
ALARM 84
Active accelerator
Acceleration potentiometer not idle when
starting the machine
bring back to idle
ALARM 85
Active forward / back
Active forward / backward keys during
machine start-up
Release control
ALARM 86
Internal error
Board internal voltage out of limits.
Internal control.
Contact assistance
ALARM 88
Flat battery
Battery too flat to enable the ascent
Ascent not enabled,
Recharge
ALARM 92
Active height limiter
Pressed top limit switch
ALARM 93
Activated anti-crush
Enabled anti-crush
ALARM 94
High Radar
Active top radar
ALARM 95
Front Radar
Active front radar
ALARM 96
Rear radar
Active rear radar
ALARM 140
Loading platform error
Platform drive error due to current
detection beyond the drive limit
Restart the machine
ALARM 144
Bed error
Disconnected platform motor
Disconnected motor
ALARM 145
Bed error
Active platform controls at start-up
Set the controls back to idle