CH193VMC

CENTRALISED CONTROL 

FOR VMC UNITS

Code:  AP 20047

AP 20048

AP 20050

              AP 20052

              AP 20054

              AP 20056

              AP 20058

INSTRUCTIONS FOR USE

FANTINI COSMI S.p.A.

Via dell’Osio, 6 20049 Caleppio di Settala, Milan – ITALY

Tel. +39 02 956821 | Fax +39 02 95307006 | [email protected]

www.fantinicosmi.it

Summary of Contents for CH193VMC

Page 1: ...S Code AP 20047 AP 20048 AP 20050 AP 20052 AP 20054 AP 20056 AP 20058 INSTRUCTIONS FOR USE FANTINI COSMI S p A Via dell Osio 6 20049 Caleppio di Settala Milan ITALY Tel 39 02 956821 Fax 39 02 95307006...

Page 2: ...el for the advanced control of ventilation systems through VMC Equipped with temperature relative humidity and VOC sensors it automatically controls ventilation and indoor air quality IAQ Note The CH1...

Page 3: ...i function touch icons 5 VMC ventilation status 6 Operating mode 7 Bar graph to display messages and daily programming Please note the function of the multi function keys varies depending on the situa...

Page 4: ...Communication mode ModBus RTU master Data formats 9600 bps 8 bits no parity 1 bit stop Maximum room temperature 45 C Storage temperature 10 C 60 C Rated pulse voltage 4000V Software Class A Insulation...

Page 5: ...ING TO THE PREVIOUS SETTINGS IS DISPLAYED 20 6 4 INTEGRATION ONLY AVAILABLE WITH THE INTEGRATION FUNCTION ACTIVE 21 6 5 AIR RETURN AIR TEMPERATURE PROBE INSIDE THE VMC 21 6 6 H2 EXHAUST AIR TEMPERATUR...

Page 6: ...iance with the requirements concerning the installation of electrical equipment ATTENTION Installation operations must be performed with the system s power disconnected CH193VMC must be installed on t...

Page 7: ...UNITS CH193VMC Place the rear body in the wall box Make the electrical connections refer to 2 ELECTRICAL CONNECTION and secure the rear body to the wall with the screws provided Hook the front of the...

Page 8: ...power ones using separate corrugated tubes at a distance of about 1 5m from each other 4 Use shielded and twisted cables and ground them on the CH193VMC side 8 CENTRALISED CONTROL FOR VMC UNITS CH193...

Page 9: ...when there is an external demand for dehumidification and or heating cooling integration For all other machines a direct connection to the EXT IN input is sufficient It is necessary to set from Advanc...

Page 10: ...y After 60 seconds of no interaction the display goes back to the main screen allows you to CONFIRM allows you to PROGRAM 1 1 DATE AND TIME SETTING Note by pressing always allows you to go back to the...

Page 11: ...oll through the hours 1 1 PROGRAMMING SETTING VMC PROFILE On the remote panel you can set the ventilation profiles fan speeds of the VMC on 7 days and different for Summer Winter 2s 2 1 15 25 15 09 20...

Page 12: ...r manual operation T MAN and automatic operation T ECO TCOMF When TEMP is selected AUTO is displayed then follow the procedure described in 3 and 4 Note Can be set from the Advanced Programming menu I...

Page 13: ...eeze only for WINTER OFF only for SUMMER In winter tE tC in summer tC tE Note Pressing ENTER to go to the next day Pressing COPY allows you to copy the temperature profile displayed to the following d...

Page 14: ...ty is displayed DISP RH Relative humidity is displayed DISP EXT the input used is displayed OFF ALR C ALARM CLOSED ALR O ALARM OPEN INTEG INTEGRATION 2s 2 1 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF...

Page 15: ...ASSWORD When the keyboard is locked you can only press the SEL key Pressing SEL allows you to enter the set password and unlock the keyboard DISP INTEG the time schedule of the integration is displaye...

Page 16: ...me for an unlimited time until a new command is given AUTO WEEKLY PROGRAM The device manages time programme settings on a weekly profile Speeds V1 V2 V3 OFF can be set every half hour OFF SYSTEM OFF P...

Page 17: ...1 1 SELECTING THE OPERATING PROGRAM The ventilation programmes of the VMC are selected in cycles 2 1 2s 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF 15 25 15 0...

Page 18: ...ture value T MAN Manual Temperature between 5 and 35 C can be set Note adjustment does not depend on the room temperature read by the CH193VMC sensor but on the AIR probe inside the VMC see paragraph...

Page 19: ...tCOMF comforttemperature temperature value between 5 and 35 C Note adjustment does not depend on the room temperature read by the CH193VMC sensor but on the AIR probe inside the VMC see paragraph 6 5...

Page 20: ...son is displayed Note With integration active and ventilation in MAN will be displayed VMC INT With integration off and ventilation in MAN will be displayed VMC V1 With ventilation in AUTO in both cas...

Page 21: ...EMPERATURE PROBE INSIDE THE VMC 1 1 H2 EXHAUST AIR TEMPERATURE PROBE INSIDE THE VMC 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF AUTO 3 DAY 1 2 15 25 15 09 20 3 DAY ENTER 15 25 15 09 20 23 0 SEL TEMP PR...

Page 22: ...used is displayed OFF ALR C ALARM CLOSED ALR A ALARM OPEN INTEG INTEGRATION 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF AUTO 3 DAY 1 2 15 25 15 09 20 3 DAY ENTER H4 ENTER 15 25 15 09 20 23 0 SEL TEMP P...

Page 23: ...arameter indicates the level of ambient air quality detected by the sensor Quality of each notch very bad poor discreet good excellent 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF AUTO 3 DAY 1 2 15 25 1...

Page 24: ...year TMAX maximum room temperature measured the previous day TMIN minimum room temperature measured the previous day RESET Pressing DISP on the CURRENT MONTH PREVIOUS MONTH and CURRENT YEAR screens di...

Page 25: ...lows you to adjust the display s backlight sky blue light with a duration that can be programmed between 5 and 30 seconds or always on 1 1 DISPLAY LIGHTING INTENSITY Allows you to modify the luminous...

Page 26: ...ht saving time applicable in Europe and some other countries This set up automatically updates the time when it changes March and October default YES Allows the machine to be operated only in ventilat...

Page 27: ...to the air flow rates defined in the design phase Each speed can be set from 0 to 100 of the fan according to the logics defined in the following points The following functions can be selected by pre...

Page 28: ...inimum value of Boost 1 1 1 V3 V3 50 ENTER 1 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF AUTO 3 DAY 3s 2s 2 3 V1 50 ENTER UP TO UP TO Note BOOST can be set between the maximum of V3 and 100 1 1 1 BOOST...

Page 29: ...NTROL FOR VMC UNITS Note INT can be set between 50 and 100 1 1 1 INT Can only be set if the Integration function is active 1 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF AUTO 3 DAY 3s INT 50 ENTER 2s 2...

Page 30: ...ated when heating and or cooling integration is desired Defines the minimum value of the set point operating range that can be set between 5 and 35 C T MIN T MAX 1 15 25 15 09 20 23 0 SEL TEMP PROG DI...

Page 31: ...EMENT It allows the temperature difference between the OFF and ON status to be managed Defines the maximum value of the set point operating range that can be set between 5 and 35 C T MIN T MAX DIFF 0...

Page 32: ...the VMC which due to the recessed wall installation or perhaps a non ideal height might not indicate the true temperature perceived Note the tA that can be set is between 5 0 and 7 0 C or OFF 2s 2 1...

Page 33: ...ly from outside into the room 1 1 CELSIUS FAHRENHEIT This allows you to choose the temperature display scale between Celsius and Fahrenheit degrees default CELSIUS CELSIUS ENTER 26 0 2s 2 1 CELSIUS FA...

Page 34: ...ates the ventilation air flow rate of the HVAC according to the values detected by the relative humidity RH and room quality VOC sensors on the device If the relative humidity in the room exceeds the...

Page 35: ...the intervention threshold from MID Off 100 to MAX MAX Off MID to 500 If the air quality in the room exceeds the set point values the VMC automatically increases ventilation to re establish optimum a...

Page 36: ...used during programming default ITALIAN 3 RESET NO ENTER ITALIANO ENTER 2s 2 1 ITALIANO INGLESE RUSSO FRANCESE SPAGNOLO TEDESCO ITALIANO ENGLISH FRANCAIS ESPANOL DEUTSCH PYCCK 15 25 15 09 20 23 0 SEL...

Page 37: ...on indicates the respective fault COMM communication error SENS AIR AIR probe SENS H4 H4 probe BAD WATER N D SENS H2 H2 probe BAD H4 H4 unsuitable OT RESISTANCE high temp resistance MOTOR motor failur...

Page 38: ...e described in points 3 Note A delta value between 2 and 10 C can be set 1 1 EXT IN Allows you to set the input to be used on the system 2s 2 1 CHG 0 ENTER 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF A...

Page 39: ...lows for an audible alarm in case of anomalies 1 1 BEEP Allows for an acoustic signal when keys are pressed 2s 2 1 ALR SND NO ENTER 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF AUTO 3 DAY 3s UP TO 2s 2...

Page 40: ...software version of the programmable thermostat 1 1 LED Allows the LED on the front of the CH193VMC panel to flash CH193VMC V3 0 ENTER 2s 2 1 15 25 15 09 20 23 0 SEL TEMP PROG DISP OFF AUTO 3 DAY 3s U...

Page 41: ...TROL FOR VMC UNITS 1 1 RESETTING DEFAULT PARAMETERS This allows you to reset all the parameters except date and time to the factory settings RESET NO ENTER 2s 2 1 3 15 25 15 09 20 23 0 SEL TEMP PROG D...

Page 42: ...icipating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment and human...

Page 43: ...43 CENTRALISED CONTROL FOR VMC UNITS CH193VMC...

Page 44: ...FANTINI COSMI S p A Via dell Osio 6 20049 Caleppio di Settala Milan ITALY Tel 39 02 956821 Fax 39 02 95307006 info fantinicosmi it www fantinicosmi it EN79973E 10 2022...