Summary of Contents for FTC-P-18-5

Page 1: ...ire technical manual before attempting to install operate or perform maintenance on this equipment Contact your supplier if you do not understand these instructions Failure to follow these instructions may lead to serious injury or death Retain these instructions for future reference All operators are to read and understand this manual CAUTION ...

Page 2: ... of Contents Overview of Fan Tech High Pressure Misting System 5 Start up and Operation Procedures 5 Maintenance 7 Troubleshooting 8 Replacement Parts 10 Consumable Common Parts 10 Warranty 11 Appendix 12 Parts Diagram 12 Control Panel 13 Fan Controls 13 Nozzle Components 14 ...

Page 3: ... to the tank through the garden hose connection on the back of the unit 1 Connect the water supply to the 3 4 female garden hose adapter on the back of the unit The water supply should meet the following conditions Flow rate of 1GPM or more Water less than 7 5 pH Pressure between 15 75 PSI Dissolved solid content less than 500 PPM Possible damage from improper water supply includes Clogged misting...

Page 4: ...alve when turning the system ON see appendix for ball valve location See the troubleshooting section if the system fails to operate The mist should form a cone shape when exiting the nozzle If the cone is not even or if the nozzle appears to be leaking see the troubleshooting section Do not increase the system pressure above 1000 PSI Damage to internal components may occur 4 Turning on the Fan Con...

Page 5: ...the pump and may damage the system To check the filter simply unscrew the housing from the top bracket When replacing the filter it is also good practice to clean the housing with bleach Use a few tablespoons of bleach mixed with water and scrub the inside of the housing Make sure the o ring is in place when reattaching the housing to the bracket then hand tighten and check for leaks 4 Storage Whe...

Page 6: ...m required for safe pump use Minimum is 4 nozzles Use regulator valve to adjust pressure to 1000 PSI Nozzle leaks during operation Nozzles are clogged Remove debris from nozzle tip by cleaning Nozzles are loose Turn off the system and relieve pressure to the mist rings and then hand tighten nozzles Nozzle o ring is worn Check ball in anti drip body for debris and replace if necessary Ant drip part...

Page 7: ...ring connecting rods may be damaged Have a service shop inspect Pump chatters Pump is being starved of water Insure that clean water is being supplied especially at system start up Check for clogged pipes or tubes Broken or worn bearing Have service shop inspect and replace if necessary Stuck inlet discharge valves Have service shop inspect valves and replace if necessary Pump leaks Water is leaki...

Page 8: ...rip not functioning Check integrity of anti drip ball and spring Filter housing leaks O Ring failure Inspect placement and integrity of o ring Replace if necessary Replacement Parts Please contact Flame Tech for the repair drawing packet Consumable Common Parts Misting Nozzle F10 08 001 Filter F10 10 001 Hydraulic Oil F02 06 001 ...

Page 9: ...age from lack of maintenance lack of oil or water filter changes freezing and obstruction due to scale lime dirt chemicals etc Fan Tech is not responsible for the removal and shipping of the system to Fan tech the reinstallation of the product upon its return to the customer or any incidental or consequential damages resulting from the defect removal reinstallation or shipment of the product Claim...

Page 10: ...High Pressure Misting System Technical Manual Fan Technologies Inc 12 Appendix Parts Diagram ...

Page 11: ...High Pressure Misting System Technical Manual Fan Technologies Inc 13 Control Panel Fan Controls ...

Page 12: ...High Pressure Misting System Technical Manual Fan Technologies Inc 14 Nozzle Components Fan Technologies Inc PO Box 1776 Cedar Park TX 76813 By D Kowal Date XX XX XXXX ...

Reviews: