Fantech AEV Series Installation Manual Download Page 1

AEV Series

Air Exchanger Ventilator

Installation Manual

Item #: 401334

Rev Date: 2017-06-21

Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of 
such requirements, with the current edition of the National Building Code, and / or ASHRAE’s “Good Engineering Practices”.

Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, 
components and specifications to maintain their technological leadership position. 
Please visit our website www.fantech.net for more detailed technical information.

United States

10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915

Canada

50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116

Summary of Contents for AEV Series

Page 1: ...e and or ASHRAE s Good Engineering Practices Fantech reserves the right to modify at any time and without notice any or all of its products features designs components and specifications to maintain their technological leadership position Please visit our website www fantech net for more detailed technical information United States 10048 Industrial Blvd Lenexa KS 66215 Tel 800 747 1762 Fax 800 487...

Page 2: ...bsence of such requirements it is recommenced to check with local authorities having jurisdiction in your area prior to installing this product VEUILLEZ LIRE LE MANUEL AVANT D INSTALLER L APPAREIL Les produits sont conçus et fabriqués pour fournir une performance fiable mais ils ne sont pas garantis à 100 sans défaut Même les produis ont des pannes occasionnelles et cette possibilité devrait être ...

Page 3: ...eatherhood Location 7 Installing the ducting to the weatherhood 7 INTERIOR DUCTING INSTALLATION Exhaust Air Ducting 8 Dedicated Installation for Existing Home 8 AEV INSTALLATION Location 9 Mounting 9 AIRFLOW BALANCING 10 PITOT TUBE BALANCING PROCEDURE 11 MAINTENANCE 12 WIRING DIAGRAM 13 TROUBLESHOOTING 14 AEV MAINTENANCE CHART 15 PARTS LIST 31 ...

Page 4: ... 13 CFM Room Count Method Determining your airflow requirement ASHRAE method Ventilation Air requirements Floor area Bedrooms 0 1 2 3 4 5 6 7 7 Ft2 m2 CFM L s CFM L s CFM L s CFM L s CFM L s 1500 139 30 14 45 21 60 28 75 35 90 42 1501 3000 139 1 279 45 21 60 28 75 35 90 42 105 50 3001 4500 279 1 418 60 28 75 35 90 45 105 50 120 57 4501 6000 418 1 557 75 35 90 42 105 50 120 57 135 64 6001 7500 557 ...

Page 5: ...e home Intermittent high speed ventilation can be obtained through a variety of optional remote controls found in this manual Below are some examples of seasonal operation of an AEV Fall Rain and rapid temperature changes make it difficult to control the internal humidity level and may result in condensation on the windows A remote dehumidistat may help give greater control over the inside environ...

Page 6: ... air is extracted from the rooms with high humidity levels and the fresh air is delivered in the living areas In this case a complete ducting system for ventilation must be installed 2 Follow local building codes Supply Air Out Bedrooms Exhaust Air In Closest To Bathroom Bathroom Fresh Air To Living Room Central Dehumidistat Exhaust Air In Kitchen Area Air Exchanger Exhaust Air Out Supply Air In ...

Page 7: ... The insulation should remain full and not be squished The outer liner which acts as a vapor barrier must be completly sealed to outer wall and the AEV using tape and or caulking A good bead of high quality caulking preferably acoustical sealant will seal the inner flexible duct to both the AEV port and the weatherhood prior to clamping To minimize air flow restriction the flexible insulated duct ...

Page 8: ...installed on the ceiling or on the wall 6 152 mm to 12 305 mm from the ceiling Dedicated installation for existing home non force air heating cooling system 1 Begin with the duct collar marked Exhaust Air In Slide a short piece 12 of flexible duct over the duct collar Insert one to two screws through the duct and into the plastic duct collar to secure it into place Apply sealant or aluminum tape t...

Page 9: ...ing 1 Although we recommend installing the unit as shown the flexibility offered by our centrifugal external rotor motor allows for the unit to be installed in any position 2 Use screws and mounting bracket supplied with the unit Install the unit close to the outside wall on which the supply and exhaust hoods will be mounted Have a nearby power supply 120 Volts 60 Hz Have the possibility of mounti...

Page 10: ...it s maximum efficiency The unit s use could cause negative or positive pressure in your home causing cold air to enter or other combustible equipment to backdraft A The duct s airflow velocity is measured with a magnehelic gauge and a pitot tube See Pitot Tube Balancing Procedure next page B This airflow measuring station reads the airflow by being connected to the ducting To avoid airflow turbul...

Page 11: ...bly to 3 digits of resolution The tube coming out of the top of the pitot is connected to the high pressure side of the gauge The tube coming out of the side of the pitot is connected to the low pressure or reference side of the gauge Insert the Pitot tube into the duct pointing the tip into the airflow For general balancing it is sufficient to move the pitot tube around in the duct and take an av...

Page 12: ...ferent operating modes Filter The filter needs to be checked and cleaned every three months or when it appears dirty To clean remove the filter and vacuum If the filter still appears dirty it can be washed in warm sudsy water mild detergent Replace the filter if it becomes too soft after washing The filter should be replaced yearly or when it can no longer be cleaned properly You may have to chang...

Page 13: ...13 Wiring diagram F ...

Page 14: ...use grilles closed or blocked Check and open grilles Damper are close if installed Poor power supply at site Have electrician check supply voltage at house Ductwork is restricting thE AEV Check duct installation Improper speed control setting Increase the speed of the AEV AEV airflow improperly balance have contractor balance AEV Supply air feels cold Poor location of supply grilles the airflow ma...

Page 15: ...responsible to adhering to all codes in effect in his area The warranty is limited to 5 years on parts and 7 years on the motor from the date of purchase including parts replaced during this time period If there is no proof of purchase available the date associated with the serial number will be used for the beginning of the warranty period This warranty is the exclusive and only warranty in effec...

Page 16: ...16 Notes ...

Page 17: ...erie appropriées de l ASHRAE Fantech se réserve le droit de modifier partiellement ou entièrement en tout moment et sans préavis les caractéristiques la conception les composants et les spécifications de ses produits afin de conserver sa position de leader de technologie S il vous plaît visitez notre site siteweb www fantech net pour des informations techniques plus détaillées United States 10048 ...

Page 18: ... ensemble des conduits avec hottes 22 INSTALLATION DES CONDUITS INTÉRIEURS Ensemble de conduit d évacuation 23 Installation spécialisée pour les maisons déjà construites 23 INSTALLATION DE L EA Emplacement 24 Montage 24 ÉQUILIBRAGE DU DÉBIT D AIR 25 PROCÉDURE D ÉQUILIBRAGE À L AIDE D UN TUBE DE PITOT 25 ENTRETIEN 27 SCHÉMA ÉLECTRONIQUE 28 DÉPANNAGE 29 TABLEAU D ENTRETIEN DU EA 30 LISTE DES COMPOSA...

Page 19: ...i3 min 0 47 L s 1 L s 2 13 pi3 min Méthode compte de pièces Déterminer vos besoins de ventilation Méthode ASHRAE Débit d air recommandé Superficie Chambre à coucher 0 1 2 3 4 5 6 7 7 Ft2 m2 Pi3 min L s Pi3 min L s Pi3 min L s Pi3 min L s Pi3 min L s 1500 139 30 14 45 21 60 28 75 35 90 42 1501 3000 139 1 279 45 21 60 28 75 35 90 42 105 50 3001 4500 279 1 418 60 28 75 35 90 45 105 50 120 57 4501 600...

Page 20: ...ne ventilation intermittente à haute vitesse est également possible au moyen de diverses télécommandes offertes en option voir les pages 5 et 6 du présent manuel Quelques exemples d utilisation saisonnière du EA sont présentés ci dessous Automne La pluie et les variations rapides de température nuisent à la bonne régulation du niveau d humidité et peuvent provoquer de la condensation sur les vitre...

Page 21: ...montré l air éventé est extrait à partir des salles avec des niveaux de humidité élevé et l air frais est livré dans les secteurs vivants Dans ce cas ci un système complet de canalisation pour la ventilation doit être installé 2 Suivre les codes locales Chambre à coucher Air vicié provenant de l intérieur Salle de bain Air frais Déshumidistat Air frais provenant de l intérieur Échangeur d air Évac...

Page 22: ...oprié du EA Assurez vous que l isolation demeure entière et qu elle n est pas écrasée Le revêtement extérieur qui joue le rôle de pare vapeur doit être complètement scellé sur le mur extérieur et le EA à l aide de ruban ou de produit de calfeutrage Déposez un cordon de produit de calfeutrage de première qualité du mastic d isolation acoustique de préférence pour sceller le conduit flexible intérie...

Page 23: ...e bruit ou les vibrations Pour de plus amples renseignements sur le réseau de conduits reportez vous à la section TYPES D INSTALLATIONS Les grilles doivent être posées sur le plafond ou sur le mur de 152 mm 6 po à 305 mm 12 po du plafond Installation spécialisée pour les maisons déjà construites installation de chauffage à air chaud non pulsé système de refroidissement 1 Utilisez d abord le collet...

Page 24: ...isse dans le EA et l endommager Montage 1 Bien que nous recommandions d installer l unité comme montrée la flexibilité offerte par notre moteur externe centrifuge de rotor tient compte pour que l unité soit installée dans n importe quelle position 2 Employez les vis et le support de montage fournies avec l unité Installez le EA à proximité du mur extérieur sur lequel les hottes d aspiration et d é...

Page 25: ...ficacité maximum l utilisation de l unité a pu causer la pression négative ou positive dans votre maison faisant entrer l air froid ou tout autre équipement combustible au backdraft A La vitesse du flux d air du conduit est mesurée avec une mesure magnehelic et une prise de pression totale Voir page prochaine pour d équilibrage de prise de pression totale B Cette station de mesure de flux d air li...

Page 26: ...fres de résolution Le tube provenant de la partie supérieure du tube de Pitot est relié au côté haute pression du manomètre tandis que celui provenant du côté est relié au côté basse pression ou référence du manomètre Introduisez le tube de Pitot dans le conduit en pointant le bout dans le débit d air Pour un équilibrage général il suffit de déplacer le tube de Pitot dans le conduit et de prendre ...

Page 27: ... appareil tous les ans pour en assurer l efficacité et un fonctionnement sans incidents Faites fonctionner le système et vérifiez les différents modes de fonctionnement Filtre Les filtres 2 doivent être vérifiés et nettoyé tous les trois mois ou quand ils semblent sales Lavez dans l eau sudsy chaude détergent doux ou un aspirateur a brosse doux Les filtres devraient être remplacés quand ils peuven...

Page 28: ...28 Schéma électronique F ...

Page 29: ...t ouvrez les Le registre le cas échéant sont fermés Demandez à un électricien de vérifier la tension d alimentation de la maison Alimentation inadéquate sur place Vérifiez le réseau de conduits Mauvais réglage de la commande de vitesse Augmentez la vitesse du EA Déséquilibre du débit d air du AE Demandez au contracteur d équilibrer le VRC L air fourni est froid L emplacement des grilles d aspirati...

Page 30: ...umés par l acheteur L acheteur est tenu de respecter tous les codes en vigueur dans sa région Les pièces y compris les pièces de rechange posées ultérieurement sont garanties pendant 5 ans à partir de la date d achat de l appareil Le moteur est garanti pendant 7 ans à partir de la date d achat S il n existe aucune preuve d achat la date associée au numéro de série devient la date de début de la pé...

Page 31: ...s composantes BOM Description AEV1000 40146 1 Collar 5 410529 2 Motor Assembly 405520 3 Synt Filter 40187 4 Control Switch 410212 5 2 Pos Terminal 401059 6 Auto Transformer 422710 7 Capacitor 6uF 411222 8 Relay Board 410364 ...

Page 32: ...make technical changes For updated documentation please refer to www fantech net Fantech Fantech se réserve le droit de faire des changements tech niques Pour de la documentation à jour s il vous plaît se référer au www fantech net ...