Fantech 2SHE Series Operational Instruction And Parts Manual Download Page 1

Operational Instruction and Parts Manual

Item #: 481810

Rev Date: 101414

United States

10048 Industrial Blvd., Lenexa, KS, 66215

Tel.: 800.747.1762 • 

Fax: 800.487.9915

Canada

50 Kanalflakt Way, Bouctouche, NB, E4S 3M5

Tel.: 800.565.3548 • 

Fax: 877.747.8116

2SHE Series

Direct-Drive Shutter Fans

fantech

Fantech, Inc. and Systemair Mfg. 
certify that the ventilators shown 
herein are licensed to bear the 
AMCA Seal. The ratings shown are 
based on tests and procedures 
performed in accordance with 
AMCA Publication 211 and AMCA 
Publication 311 and comply with 
the requirements of the AMCA 
Certified Ratings Program.

Summary of Contents for 2SHE Series

Page 1: ...B E4S 3M5 Tel 800 565 3548 Fax 877 747 8116 2SHE Series Direct Drive Shutter Fans fantech Fantech Inc and Systemair Mfg certify that the ventilators shown herein are licensed to bear the AMCA Seal The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program ...

Page 2: ...o the bare metal of the motor frame or other suitable means 3 Always disconnect power source before working on or near a motor or its connected load If the power disconnect point is out of sight lock it in the open position and tag to prevent unexpected application of power Caution In United States to reduce the risk of injury to persons OSHA complying guards are required when fan is installed wit...

Page 3: ... may have occurred during transit 2 Before installing rotate the propeller to be sure there are no obstructions which would interfere with proper operation Adjust as required Dimensions Air flow Dimensional information is in inches Speed Controllable Table 1 Dimensional data A Sq B C Sq G D E F Model A B C D E F G 2SHE 0721 11 1 8 4 15 16 8 1 2 3 9 16 5 3 4 3 1 4 X 1 2 2SHE 1021 13 1 8 5 9 16 10 1...

Page 4: ...rned OFF the shutter will close Maintenance Do not depend on any switch as sole means of disconnecting power when installing or servicing the fan If the power disconnect is out of sight lock it in the open position and tag to prevent application of power Failure to do so may result in fatal electrical shock Minor and routine 1 Disconnect and lock out power source before servicing 2 Lubricate the m...

Page 5: ... 3 Guard 1 1 1 4 Motor 1 1 1 5 Yoke brace 1 1 6 Grommet 4 7 10 x 3 4 Flat washer 4 4 8 3 8 24 x 1 HHCS screw 1 1 9 3 8 24 Spinlock nut 1 1 10 10 32 Spinlock nut 4 4 11 10 16 x 5 8 S M screw 4 4 12 3 8 x 13 16 Flat washer 1 13 8 32 Spinlock nut 4 14 10 32 x 1 0 HWH screw 8 Standard hardware item available locally Figure 3 Repair parts illustration 9 Replacement Part List ...

Page 6: ...eller Fan inoperative 1 Blown fuse or open circuit breaker 2 Defective motor 3 Speed control set too low 1 Replace fuse or reset circuit breaker 2 Repair or replace motor 3 Increase speed with controller Insufficient air flow 1 Blocked intake or exhaust opening 2 Low voltage 3 Speed control set too low 1 Clear opening of obstruction or increase size of opening 2 Determine cause and correct 3 Incre...

Page 7: ...tment 10048 Industrial Blvd Lenexa KS 66215 Included in the claim should be Order Number Model Numbers Serial Numbers and a detailed description of the issues Purchaser assumes all other responsibility for any loss damage or injury to persons or property arising out of the use of our products either alone or in combination with other products or components THE SOLE AND EXCLUSIVE REMEDY FOR BREACH ...

Page 8: ...fantech Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech ...