4.11 Function 37. Instantaneous phase undercurrent
This protection function can be set by using the following parameters:
Function
Description
Minimum
Maximum
Step
Unit
Default
37 (*)
Instantaneous phase undercurrent
Function Enable
-
-
No/Alarm/Trip
-
No
Current Tap
0.010
30.000
0.001
xIn
0.500
Minimum Level
0.000
1.000
0.001
xIn
0.000
Time delay
0.060
300.00
0.001
s
0.200
(*) Optional depending on model
The setting “Minimum level” indicates the minimum level of current it is necessary to measure to work
with the function. This is, if the measured current is lower than the “Minimum Level” setting, the function
will not trip although this current is lower than the tap.
The time delay is independent from the operating current flowing through the relay, so if the phase
current drops below its predetermined value for an equal or greater amount of time than this preset
value, the protection function activates (trips) and does not reset itself until the average value of the
phase exceeds the point of current pick-up.
The function activates at 100% of the preset input and deactivates at 105%. The reset is instantaneous.
The accuracy of the Time Delay is equal to the set time delay ±30ms or ±0.5% (whichever is greater).
4.12 Function 52. Circuit Breaker monitoring
This control function can be set by using the following parameters:
Function
Description
Minimum
Maximum
Step
Unit
Default
52 (*)
Circuit breaker monitoring
Maximum number of openings
1
100000
1
-
1000
Maximum accumulated amperes
1
100000
1
M(A²)
100
Repetitive number of openings
1
100000
1
-
3
Time for repetitive number of openings
1
300
1
min
3
Maximum opening time
0.020
300.000
0.001
s
0.10
Maximum closing time
0.020
300.000
0.001
s
0.10
(*) Optional depending on model
Summary of Contents for SIL-A A Series
Page 8: ...www fanox com Rev 04 8 112 2 1 2 Case dimensions The dimensions are in mm...
Page 9: ...www fanox com Rev 04 9 112 2 1 3 Connection diagrams 2 1 3 1 Analog connections...
Page 12: ...www fanox com Rev 04 12 112 2 2 SILA with short circuitable current terminals 2 2 1 Front view...
Page 13: ...www fanox com Rev 04 13 112 2 2 2 Case dimensions The dimensions are in mm...
Page 14: ...www fanox com Rev 04 14 112 2 2 3 Connection diagrams 2 2 3 1 Analogic connections...
Page 22: ...www fanox com Rev 04 22 112 3 3 Functional diagram...
Page 61: ...www fanox com Rev 04 61 112...
Page 63: ...www fanox com Rev 04 63 112...
Page 64: ...www fanox com Rev 04 64 112...
Page 65: ...www fanox com Rev 04 65 112...
Page 111: ...www fanox com Rev 04 111 112 11 APPENDIX NOTES...