Programming of the baud rate (

SET BDR

) (only for vers. with serial output)

The following setting is the baud rate. The message 

SET

 appears on

G

 display, the message 

SET BDR

 on the first two 

parts of 

F

 display to indicate the programming of the baud rate displayed on the third part (L3) of the 

F

 display. To modify 

the value set, it’s necessary to use the 

C

 key to decrease and 

B

 to increase the rate. The values settable are: 

-

19.2

 => 19200 

baud 

-

9.60

 => 9600 

baud 

-

4.80

 => 4800 

baud 

-

2.40

 => 2400 

baud 

Press 

A

 to confirm the value displayed. 

Programming of the serial parameters (only for vers. with serial output)

On

G

 display will appear the message 

SET

. The following message will appear on 

F

 display using the 

B

 and 

C

 keys. To 

confirm press the 

A

 key. 

8  1

 

8 data bit / 1 stop bit

PAR

No parity

NO

8  2

 

8 data bit / 2 stop bit  

PAR

No parity 

NO

8  1

 

8 data bit / 1 stop bit

PAR

Even parity 

EVE

8  1

 

8 data bit / 1 stop bit 

PAR

Odd parity 

ODD

Programming of the Password (

SET PAS

)

The instrument is supplied without password. When a password (from 0002 to 9999) is set, using the 

B

 (to increase), 

C

(to decrease) and 

A

 (to confirm) keys, only who know this value can to enter in the setup. The password, in fact, is 

required all the time that someone try to enter in the setup (pressing the 

A

 and 

B

 key at the same time). If the password 

is wrong, the message 

PASS ERR

 will appear on 

F

 display and the instrument go back to the measures visualization. 

To input the password, when required by the instrument, at the enter of the setup, use the 

A

,

B

 and 

C

 keys as the same 

way done previously. 

The menu is cyclic. After the last setting, the instrument go back to the first page of Setup (SETUP). It’s always possible 
to come back to measures visualization mode pressing at the same time the 

A

 and 

C

 keys. 

PEAK VALUES AND ENERGY COUNTERS RESET (

RESET

)

From the measures visualization mode, pressing the 

A

 and 

C

 keys simultaneously the message 

SETUP

 will appear on 

F

display, press the key 

C

 until the message 

RESET

 appears on the same display. To accede to the menu, press the 

A

key. Now it’s possible to select the enabling of cancellation type, by pressing the 

C

 key, according with following types: 

RESET PEA

: all maximum value will be delete. 

RESET AVG

: all average and average maximum value (maximum demand) will be delete. 

RESET EN

: with 

NORMAL

 as energy mode (

EN

) the total energy counters will be delete, with 

TOT PAR

 the partial 

energy counters will be delete. 

RESET ALL

:  to delete all average and maximum values and all energy hours counters. 

Entry to menu: 

seT UP

Æ

seT Up
RESET
SET DO1 
SET DO2 
SET HR_ 
--- OFF OFF

  

(the visualization depends on the settings and the I/O status)

RESET PEA 

NO

 / 

YES

Confirm Reset

Deleting maximum values (max) 

RESET AVG 

NO

 / 

YES

Confirm Reset

Deleting average values (avg) 
and maximum demand (maxD) 

RESET EN 

NO

 / 

YES

Confirm Reset

Deleting energy counters 

RESET ALL 

NO

 / 

YES

Confirm Reset

Deleting maximum and average 
values, and energy counters 

To enable the chosen type, press the 

B

 key to change the indication on display 

G

 from 

NO

 to 

yes

.

Confirm enabling cancellation, by pressing the 

A

 key. The indication on display 

G

 change from 

yes

 to

---

  . 

www.fanox.com

[email protected]

Tel: 0034 94 471 14 09

Fax: 0034 94 471 05 92

Pag 7

Summary of Contents for EMM-5

Page 1: ...port serial port in alternative to the digital output power supply different from standard version current input 1A MEASURED PARAMETERS parameters unit of measurement initial identification phase and three phase voltages V kV V L1 N V L2 N V L3 N 6 V L N phase to phase and three phase system voltages V kV V L1 L2 V L2 L3 V L3 L1 6 V L L phase and three phase currents A kA A L1 A L2 A L3 6 A phase ...

Page 2: ...le voltage 400V 300 500V phase to phase 175 290V phase neutral 230V 175 290V phase to phase 130 170V phase neutral L2 L3 phase to phase power supply 110V 85 145V phase to phase 50 85V phase neutral 230V 300 500V phase to phase 175 290V phase neutral L3 N phase neutral power supply 110V 175 290V phase to phase 100 170V phase neutral The standard version allows to apply the instrument at all the thr...

Page 3: ... SINGLE PHASE LINE if the multimeters are used on single phase line the measure are referred at the L3 phase The others data displayed relatives at value of three phase system are not to consider I2 C I I1 I3 S1 S2 VL1 VL2 VL3 N EMM I2 C I I1 I3 S1 S2 VL1 VL2 VL3 N EMM I2 C I I1 I3 S1 S2 VL1 VL2 VL3 N EMM measure current inputs measure current inputs measure current inputs measure current inputs m...

Page 4: ...t energy counters If it s selected with the A and B keys the display indicates the maximum and average values G display for the visualization of the electrical measure indicated in LED E energy counters excluded The voltage values are referred to the three phase system The k LED displays the reading in kilo x 1000 If it s selected with C key the display indicates the type of the energy displayed I...

Page 5: ... 0 kW kVAr pulse 0 10 kW kVAr pulse 0 01 kW kVAr pulse seT TPL Increase from 100 to 500 mS in step by 100 mS Decrease version with digital output seT ID ADR Increase Set address of network from 001 to 127 Decrease version with serial output seT SER BDR Set baud rate 19200 baud 19 2 serial interface 9600 baud 9 60 version with serial output 4800 baud 4 80 2400 baud 2 40 seT PAR Set parameters of bi...

Page 6: ...rease it press the C key To confirm it press the A key The average time is the time used to calculate the average parameters avg and the maximum demand maxD Programming of the energy visualization type seT EN This setting allows to define the energy visualization type after the visualization of the temperature With TOT PAR will have the visualization of the partial and total energy counters With N...

Page 7: ...he enter of the setup use the A B and C keys as the same way done previously The menu is cyclic After the last setting the instrument go back to the first page of Setup SETUP It s always possible to come back to measures visualization mode pressing at the same time the A and C keys PEAK VALUES AND ENERGY COUNTERS RESET RESET From the measures visualization mode pressing the A and C keys simultaneo...

Page 8: ... HI and ALR LO With ALR SYS 123 the digital output will function as alarm verifying that the maximum value of the single phases doesn t exceed the maximum threshold set ALR HI and that the minimum value of the single phases doesn t come down the minimum threshold set ALR LO The activation of the alarm output will come after some seconds of delay set ALR DL In the REMOTE mode the output status will...

Page 9: ...OLDS On F display will appear the message ALR Hi with the high threshold value confirming with the A key on the same display will appear the message ALR LO with low threshold value The B to increase and C to decrease keys are used to set the high and the low thresholds values The range depends by the parameter and it is linked to the CT and VT ratios Pressing A key to confirm The threshold set is ...

Page 10: ...and the A key to confirm it SET THE THRESHOLD Subsequently it s necessary to set the threshold using the B to increase and C to decrease keys Confirm with A key I O INFO PAGE After the hour counter set the I O info page appears in F displays on the second part L2 the status of the first digital output DO1 on the third part L3 the status of the second digital output DO2 The visualization of the sta...

Page 11: ...ton to select the parameter that can be displayed and indicated from E LED The voltage values are of the three phase system the frequency is of the L1 channel Visualization energy and hours counters With the C key it s possible to visualize on F display the active reactive and apparent energy counters One segment of the right digit of the G display in correspondence of the kWh and KVArh on the fro...

Page 12: ...xD avg I L1 max avg I L2 max avg I L3 max avg phase currents maximum of average phase currents max demand max maxD avg 6 W max avg 6 VAr max avg 6 VA max avg three phase power maximum of average three phase powers maximum demand max maxD avg I L1 avg I L2 avg I L3 avg phase currents average phase currents max maxD avg 6 W avg 6 Var avg 6 VA avg three phase power average three phase powers max maxD...

Page 13: ...32 485 converter between the RS232 PC s outlet and the instrument s it s necessary to insert a line termination resistance Rt 100 120 ohm between the twisted pair of cables placing it between the converter and the end of the network last instrument connected Use always twisted cables with minimum section of 0 36mm2 22AWG and lower capacity of 60 pF m i e BELDEN cable type EIA RS485 Ref 3105A Shiel...

Page 14: ...EMM 5 instruction manual IM441 EU F v0 4 pag 14 DIMENSIONS 92 92 R3 96 96 90 96 56 9 20 cut panel www fanox com fanox fanox com Tel 0034 94 471 14 09 Fax 0034 94 471 05 92 Pag 14 ...

Page 15: ...single phase insertion in MT with external TV and transforming rate programmable from 0 1 to 400 0 current inputs from 0 02 to 5A permanent overload 30 from external TA with secondary 5A primary programmable from 5 to 10000A auto consumption 0 5VA INPUTS OUTPUTS digital outputs Two outputs with common optomos 12 230Vac dc max 150mA Insulation 3kV for 60 second Pulse Function Weight programmable 0 ...

Page 16: ...M425 UE F v2 2 pag 16 Parque Tecnológico de Bizkaia Edif 604 48160 DERIO BIZKAIA ESPAÑA Tel 0034 94 471 14 09 Fax 0034 94 471 05 92 E mail fanox fanox com Web www fanox com www fanox com fanox fanox com Tel 0034 94 471 14 09 Fax 0034 94 471 05 92 Pag 16 ...

Reviews: