Fanimation Windpointe FP7400 Owner'S Manual Download Page 1

OWNER’S MANUAL

READ AND SAVE THESE INSTRUCTIONS

Models No. FP7300, FP7400, FP7410, FP7500, FP7510&FP7500RSP4LK

The WindPointe

®

Ceiling Fans

Windpointe™ Fan Model (Std)

Net Weight (lbs)

Net Weight (kgs)

28.46

12.91

27.75

26.29

12.58

11.95

FP7300

FP7400

FP7410

FP7500

FP7510

FP7500RSP4LK

25.57

1.60

25.57

33.25

15.1

1.60

FP7410; 4-Bladed Model

 

FP7400; 4-Bladed Model

FP7500; 5-Bladed Model

FP7510; 5-Bladed Model

FP7300; 3-Bladed Model

FP7500RSP4LK; 5-Bladed Model

Summary of Contents for Windpointe FP7400

Page 1: ...Ceiling Fans Windpointe Fan Model Std Net Weight lbs Net Weight kgs 28 46 12 91 27 75 26 29 12 58 11 95 FP7300 FP7400 FP7410 FP7500 FP7510 FP7500RSP4LK 25 57 1 60 25 57 33 25 15 1 1 60 FP7410 4 Bladed Model FP7400 4 Bladed Model FP7500 5 Bladed Model FP7510 5 Bladed Model FP7300 3 Bladed Model FP7500RSP4LK 5 Bladed Model ...

Page 2: ...amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan Important Safety Instructions WARNING To avoid fire shock and serious personal injury follow these instructions Table of Contents Unpacking Instructions 3 Energy Efficient Use of Ceiling Fans 4 Electrical and Structural Requirements 4 How to A...

Page 3: ...iver One wire stripper Three wire connectors supplied Ceiling Canopy Blade Set not shown see parts list for more details Hardware bags 20 x 20 x 14 blade holder to fan motor hub screws with lockwashers 3 16 24 carriage head nut 3 16 24 x 11mm Models FP7300 FP7400 blade to blade holder washer head screws 3 16 3 16 24 x 13mm Model FP7500RSP4LK blade to blade holder washer head screws 24 x 17mm Model...

Page 4: ...y need to be replaced Consult a qualified electrician if in doubt Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure efficient product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 ...

Page 5: ...anopy on fan shown with open side facing up Figure 3 5 Reinstall the Hanger Ball Figure 1 on the Downrod as follows Route the three 80 wires and cable through the Hanger Ball Position the Pin through the two holes in the Downrod and align the Hanger Ball so the Pin is captured in the groove in the top of the Hanger Ball Pull the Hanger Ball up tight against the pin Securely tighten the setscrew in...

Page 6: ...the flat washer safety cable loop and into the building structure Figure 2 You will first drill a pilot hole into the building structure to prevent splitting or cracking 2 Securely attach the hanger bracket to ceiling junction box acceptable for ceiling fan support NOTE Ceiling support cable cannot be secured to junction box only it must be directly secured to ceiling joist or structural member us...

Page 7: ...Listed Outlet Box Black Green Wire Ground from Hanger Bracket Green Wire Ground Black Fan Wire White Blue Green Wire Ground from Hanger Bowl Figure 1 WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation...

Page 8: ...g Switch Cup Adapter assembly by removing three screws Figure 4a 7b Disassemble the Switch Cup Adapter Assembly with Light Fitter by removing three screws Figure 4b 8 Remove one of the three screws in the support bracket Slightly loosen the remaining two screws Assemble the adapter assembly to the housing support bracket using the two key slots in the adapter assembly Replace the third screw and s...

Page 9: ...y process Assembling and Mounting the Fan Blades and Switch Hsg cont d 9a Assemble the Adapter assembly on the Housing Support bracket and tighten three screws Securely attach the 9 pins witch cup connector to wiring harness socket within Adapter assembly Figure 6a Figure 6a Figure 6b 9b FP7500RSP4LK ONLY Connect the 2 pin connector from the switch cup housing light fitter to the 2 pin connector fr...

Page 10: ... pull chains and fobs Figure 3 Bulb is pressurized and may shatter DO NOT TOUCH BULB WITH BARE HANDS Fingerprints may result in shorter bulb life Remove fingerprints with alcohol prior to use To reduce the risk of fire use 75 watt max type T4 minican JD E11 tungsten halogen bulb Turn off the wall switch and allow the bulb to cool for 10 minutes before relamping 4 Restore Power and your fan is now ...

Page 11: ...e main fuse box Figure 1 3 If airflow is desired in the opposite direction turn the fan off and wait for the blades to stop turning Then slide the reverse switch to the opposite position and turn fan on again Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows Figure 3 Reversing Switch Figure 1 MAIN FUSE BOX 2 Check the operation of the fan b...

Page 12: ...ning HDWFP51 5 32 Threaded Rods 2 HDWHW50 5 32 External Lockwasher 2 Knurled Knobs 2 Blade Balance Kit BALKT Chain Coupler Chain Fob Wire Connectors 4 Blade Mounting Hardware Bag Containing HDWBM51 3 16 24 x 11 mm Washer Hd Screws Models FP7300 FP7400 3 16 24 x 17 mm Washer Head Screws Model FP7500 3 16 24 Carriage Head Nuts Blade Holder Mounting Hardware Bag Containing HDWBH53 20 x Phillips Head ...

Page 13: ...g 20 x Phillips Head Screws with Lock 20 x 14mm Pan Head Screws with Lock Washers Model FP7500RSP4LK Washers Philips Screwdriver 4 Support Cable Bag Containing Ceiling Support Cable with Clamp Lag Bolt 3 8 x 2 Flat Washer Not Shown Blades Part FP7500 APG610BL ADR1 6 PG165 P81090 AMA53 AP5005 AP5006 AP5063 AP5053 HDWFP53 HDWHW50 HDWBM53 HDWBH53 HWBSCABLE ISP4 5 for 7500AB ISP5 5 for 7500MW ISD4A 5 ...

Page 14: ...ed View NOTE The illustration shown is not to scale or its actual configuration may vary Figure 1 7 11 5 4 3 1 2a 2b 2c 2d 2 8 7 8 7 8 FP7300 Blade Holders FP7400 FP7410 Blade Holders FP7500 FP7510 FP7500RSP4LK Blade Holders 6a 6b 10 12 9 11 FP7500RSP4LK ONLY ...

Page 15: ...h other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 6 Tighten screws securely 7 Tighten set screw securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew in downrod support is loose 2 Setscrew in do...

Page 16: ...Copyright 2011 Fanimation 2011 10 V 01 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com ...

Page 17: ...e techo FP7300 modelo de 3 aspas FP7400 modelo de 4 aspas FP7410 modelo de 4 aspas FP7500 modelo de 5 aspas FP7500RSP4LK modelo de 5 aspas FP7510 modelo de 5 aspas Modelo de ventilador Windpointe estándar Peso neto lb Peso neto kg 28 46 12 91 27 75 26 29 12 58 11 95 FP7300 FP7400 FP7410 FP7500 FP7510 25 57 1 60 25 57 1 60 FP7500RSP4LK 33 25 15 1 ...

Page 18: ...al Se requiere comprobante de venta El cliente se hará responsable de todos los gastos de remoción o reinstalación y envío del producto para reparaciones o sustitución 2 GARANTÍA DE MANO DE OBRA DEL MOTOR POR UN AÑO si el motor de su ventilador falla antes de cumplirse un año a partir del momento de su compra original debido a defectos en los materiales o en la fabricación se efectuará la reparaci...

Page 19: ...zas póngase en contacto con su proveedor local Herramientas necesarias para el ensamblaje Materiales tamaño del cable según el A W G Calibre de Alambre Estadounidense longitud del cable instalado 14 12 hasta 15 2 m 50 pies de 15 2 a 30 5 m 50 a 100 pies NOTA si no está seguro de la descripción de una pieza consulte la ilustración del despiece Figura 1 página 25 1 Verifique que haya recibido las sig...

Page 20: ...uede ahorrar energía adicional y dinero Requisitos eléctricos y estructurales Su nuevo ventilador de techo requiere una línea de suministro eléctrico con conexión a tierra de 120 voltios de CA 60 Hz circuito de 15 amperios La caja de distribución eléctrica debe estar bien asegurada y debe ser capaz de soportar una carga de al menos 22 7 kg 50 lb La Figura 1 muestra diversas configuraciones estruct...

Page 21: ...n el barral como se indica a continuación Pase los tres cables de 2 m 80 y el cable de seguridad a través de la semiesfera Pase el pasador a través de los dos orificios en el barral y alinee la semiesfera de modo que el pasador quede atrapado en la ranura de la parte superior de la misma Empuje la semiesfera hacia arriba bien ajustada contra el pasador Ajuste firmemente el tornillo de fijación de ...

Page 22: ...ar a través de la arandela plana y el aro del cable de seguridad hacia adentro de la estructura del edificio Figura 2 Primero taladre un orificio guía de 0 6 cm en la estructura del edificio para prevenir roturas o rajaduras 2 Ajuste bien el soporte de suspensión a la caja de conexiones del techo apta para soporte de ventilador NOTA el cable de soporte para techo no se puede asegurar solamente a l...

Page 23: ...talación eléctrica NOTA si no está seguro si la caja de distribución eléctrica tiene conexión a tierra pida asesoramiento a un electricista autorizado ya que la conexión a tierra es importante para un funcionamiento seguro Figura 1a Figura 1b Suministro doméstico Caja de distribución eléctrica indicada Negro Cable verde conexión a tierra del soporte de suspensión Cable verde conexión a tierra Cabl...

Page 24: ... la unidad de la caja del adaptador del interruptor retirando 3 tornillos Figura 4a ADVERTENCIA Para reducir el riesgo de lesiones personales no doble los soportes de aspas al instalarlos balancear las aspas o limpiar el ventilador No coloque objetos extraños entre las aspas del ventilador en funcionamiento NOTA DE INSTALACIÓN No conecte las aspas hasta que el ventilador esté totalmente instalado ...

Page 25: ...el interruptor de 9 pasadores al enchufe del mazo de cables dentro del adaptador Figura 6a 9b SÓLO FP7500RSP4LK Conecte el conector de 2 clavijas desde el colocador de iluminación de la carcasa de la cubierta del interruptor hacia el conector de 2 clavijas desde la unidad del motor Figura 6b 11a Vuelva a conectar la electricidad El ventilador se 11b SÓLO FP7500RSP4LK continuarás la unidad del kit ...

Page 26: ...e NO TOQUE LA BOMBILLA CON LAS MANOS DESPROTEGIDAS Las huellas dactilares en la bombilla pueden reducir la vida útil de la misma Elimine las huellas dactilares con alcohol antes de usar la bombilla Para disminuir el riesgo de incendios utilice una bombilla minican tipo T4 JD E11 de tungsteno halógena de 75 vatios como máximo Apague el interruptor de pared y deje enfriar la bombilla durante 10 minu...

Page 27: ... Invierno Dirección de rotación En dirección de las manecillasdel reloj En dirección contraria a las manecillas del reloj Derecha Izquierda Posición del interruptor 4 SÓLO FP7500RSP4LK l e r a b o r p m o c Figura 4 funcionamiento de la luz hacia abajo tirando suavemente de la cadena del tirón luz PRINCIPAL CAJA DE FUSIBLES Conmutador inversor Conmutador inversor Mantenimiento El único mantenimien...

Page 28: ...ra el montaje de aspas que contiene HDWBM51 HDWBM55 Tornillos con cabeza de arandela de 3 16 24 x 11 mm modelos FP7300 y FP7400 Tornillos con cabeza de arandela de 3 16 24 x 17 mm modelo FP7500 Tuercas de cabeza redonda de 3 16 24 Bolsa de accesorios para el montaje de los soportes de aspas que contiene HDWBH53 HDWBH53 Tornillos de cabeza tipo Phillips de 20 x con arandelas de seguridad Destornill...

Page 29: ...4 Bolsa de accesorios para el montaje de aspas que contiene Tornillos con cabeza de arandela de 3 16 24 x 11 mm modelos FP7300 y FP7400 Tornillos con cabeza de arandela de 3 16 24 x 17 mm modelo FP7500 Tornillos con cabeza de arandela de 3 16 24 x 13 mm modelo FP7500RSP4LK Tuercas de cabeza redonda de 3 16 24 Bolsa de accesorios para el montaje de los soportes de aspas que contiene Tornillos de ca...

Page 30: ...ilustración que se muestra no está hecha a escala y su configuración real puede variar Figura 1 Soportes de aspas FP7300 Soportes de aspas FP7400 y FP7410 Soportes de aspas FP7500 FP7510 y FP7500RSP4LK 7 6a 5 4 3 1 2a 2b 2c 2d 2 8 7 8 7 8 11 6b 10 12 9 11 SÓLO FP7500RSP4LK ...

Page 31: ...de los controles de velocidad de estado sólido variables Los controles de estado sólido no son recomendables Escoja un método de control alternativo 6 Ajuste bien los tornillos 7 Asegure bien los tornillos de fijación 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fijación y la tuerca del soporte de barral están flojos 2 El tornillo de fijación en la unidad del barral de la semiesfera está floj...

Page 32: ...011 Fanimation 2011 10 V 01 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fanimation com ...