Fanimation PICKETT DRUM FP6260 Series Manual Download Page 1

Español p. 19

MODE

L

 #FP6260**

 

CEILING FAN

Questions, problems, missing parts?

 Before returning to your retailer, call our customer 

service department at 1-888-567-2055, 8 a.m.-5 p.m., EST, Monday-Friday.

ATTACH YOUR RECEIPT HERE AND REGISTER YOUR FAN AT FANIMATION.COM 

 

READ AND SAVE THESE INSTRUCTIONS

Serial Number

Purchase Date

Net Weight 26.46 lbs (12.0 kg)

PICKETT DRUM

Summary of Contents for PICKETT DRUM FP6260 Series

Page 1: ...returning to your retailer call our customer service department at 1 888 567 2055 8 a m 5 p m EST Monday Friday ATTACH YOUR RECEIPT HERE AND REGISTER YOUR FAN AT FANIMATION COM READ AND SAVE THESE INSTRUCTIONS Serial Number Purchase Date Net Weight 26 46 lbs 12 0 kg PICKETT DRUM ...

Page 2: ...s or workmanship labor to repair the motor will be provided free of charge at our national service center Purchaser will be responsible for labor charges after this one year period Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement 3 If any other part of your fan fails at any time within one year after origin...

Page 3: ...ay also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect Unpacking Instructions 4 Energy Efficient Use of Ceiling Fans 5 Electrical and Structural Requirements 5 How to Assemble Your Ceiling Fan 7 How to Hang Your Ceiling Fan 9 How to Wire Your Ceiling Fan 10 How to Install Your Canopy Housing 11 How to Opera...

Page 4: ... to make it as easy as possible for you to assemble install operate and maintain your ceiling fan Tools Needed for Assembly ne hillips head screwdriver One stepladder hree wire connectors supplied nstalled ire ength ire i e Before assembling your ceiling fan refer to section on proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or experience have your fan ...

Page 5: ...pdraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Electrical and Structural Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 HZ 15 Amp Circuit Electrical code requires use of a fan rat...

Page 6: ... box marked acceptable for fan support of 15 88 kg 35 lbs or less Use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Brace use Figure 3 Paired with a deep box this hanger is meant to span between two joists and takes the place of wooden b...

Page 7: ...ownrod Secure clevis pin with hairpin clip Tighten the two set screws with nuts in the downrod support Figure 4 WARNING It is critical that the clevis pin in the downrod support is properly installed and the set screws and nuts are securely tightened Failure to do so could result in the fan falling 2 Remove the hairpin clip and clevis pin from the bottom of the downrod Retain the pin and clip for ...

Page 8: ... Route wires and safety cable through Motor Coupling Cover Canopy Screw Cover and Ceiling Canopy Figure 5 Figure 5 Figure 7 6 Reinstall the hanger ball on the downrod as follows Route the black white and blue wires and safety cable through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ba...

Page 9: ...o clamp hole and firmly tighten screw Figure 4 Cut off excess safety cable r r r fl r r of 4 WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 2 WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 35 lbs Hanger bracket must seat rmly against outlet box If the outlet box is recessed remove wallboard until bracket contact...

Page 10: ... and carefully push leads into the outlet box with the white and green leads to one side of the box and the black leads to the other side Figure 3 CAUTION INCORRECT WIRE CONNECTION WILL DAMAGE THIS RECEIVER Figure 4 Green Wire from Supply Ground White Wire from Supply White Wire from Fan Green Wire from Hanger Bracket Ground Green Wire from Hanger Ball Ground Listed Outlet Box Household Supply Bla...

Page 11: ...an with a variable Rheostat wall controller or dimmer switch Doing so could result in damage to the ceiling fan s remote control unit How to Install Your Canopy Housing 2 Securely attach and tighten the canopy screw cover over the shoulder screws in the hanger bracket utilizing the keyslot twist lock feature Figure 2 1 Remove one of the two shoulder screws in the hanger bracket Loosen the second s...

Page 12: ...rning function There are no frequency switches on the receiver unit The receiver will automatically scan the frequency from the hand held control if any changes are made The frequency settings should only be changed in the case of interference or if multiple ceiling fans with the same type of control system are installed in the same structure 3 s 4 6 Figure 6 Dip Switch O D ...

Page 13: ...nts are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical shock CAUTION Figure 7 Reversing Switch 7 If airflow is desired in the opposite direction turn the fan off and wait for the blades to stop turning Slide the reverse switch on top of motor assembly to ...

Page 14: ...urned off 3 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 1 Loose screws in motor housing 2 Wire connectors inside housing rattling 3 Motor noise caused by solid state variable speed control 3 FAN WOBBLES EXCESSIVELY 1 Tighten both setscrews securely in downrod support 2 Tighten the se...

Page 15: ...nopy Canopy Screw Cover Assembly 15 Parts List Model No FP6260 HOW TO ORDER REPAIR PARTS When ordering repair parts always give the following information Part Number Part Description Fan Model Number Contact your retail store for repair parts Before discarding packaging material be certain all parts have been removed Insert FINISH CODES Refer to fan model number located on downrod support Wire Con...

Page 16: ...FP6260 Exploded View Illustration NOTE The illustration shown is not to scale or its actual con guration may vary Product parts are subject to change without notice Figure 1 1 10 2 3 4 5 6 8 Pickett Drum 10 9 7 ...

Page 17: ......

Page 18: ...Copyright 2017 Fanimation 2017 02 V 01 10983 Bennett Parkway Zionsville IN 46077 Phone 888 567 2055 Outside U S 317 733 4113 FANIMATION COM FAX 866 482 5215 ...

Page 19: ...N FANIMATION COM LEA Y GUARDE ESTAS INSTRUCCIONES Fecha de compra Peso neto 12 0 kg 26 46 lbs Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 888 567 2055 8 a m 5 pm hora del Este de lunes viernes MODELO FP6260 ...

Page 20: ... a fin de evitar un contacto accidental con las mismas 4 Siga las recomendaciones sobre el método correcto de instalación eléctrica de su ventilador de techo Si no posee la experiencia o 5 los conocimientos eléctricos adecuados contrate a un electricista autorizado para instalar el ventilador Apto para usar con controles de velocidad de estado sólido 6 ADVERTENCIA Monte a una caja de salida acepta...

Page 21: ...garantías implícitas Fanimation no se hará responsable por daños accidentales resultantes o especiales derivados del uso o el rendimiento del producto o en conjunción con éste excepto en los casos en los que la ley así lo disponga Esta garantía le otorga derechos legales especiales y es posible que también goce de otros derechos que pueden variar según el estado Es normal que se produzca un cierto...

Page 22: ...cable instalado 14 12 hasta 15 2 m 50 pies de 15 2 a 30 5 m 50 a 100 pies Instrucciones para el desempaque Para su comodidad marque cada uno de los pasos Amedida que completa cada paso coloque una marca deveri cación Con esto se asegurará de completar todos los pasos y podrá saber desde dónde retomar si fuera interrumpido Bolsas de accesorios Conectores de cables NOTA Si no está seguro de la descr...

Page 23: ...sentamosalgunassugerencias para asegurar un rendimiento eficiente del producto Selección del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habitación a 2 13 m 7 pies de altura del piso como mínimo y 0 5 m 18 pulgadas de las paredes Si la altura del techo lo permite instale el ventilador a 2 5 m 8 9 pies por encima del suelo para un flujo de aire óptimo Co...

Page 24: ... de que la electricidad esté desconectada en la caja de fusibles principal antes de realizar la instalación eléctrica Toda instalación eléctrica debe cumplir con los códigos nacionales y locales y el ventilador de techo debe tener la conexión a tierra adecuada como forma de precaución ante posibles descargas eléctricas ADVERTENCIA Para reducir el riesgo de incendios descargas eléctricas o lesiones...

Page 25: ...color negro blanco azul y cable de seguridad a través de la varilla Figura 3 2 Retire el clip de horquilla y pasador de horquilla de la parte inferior de la bola para colgar Retener el pasador y clip para la reinstalación en el paso 4 Figura 2 1 Extraiga la pieza de la bola colgante de la unidad de la bola colgante varilla aflojando el tornillo de presión de la bola colgante hasta que la bola se l...

Page 26: ...chón de techo Cubierta de unión del motor Cubierta del tornillo de la base 7 Corte el exceso de cable aproximadamente de 15 a 23 cm 6 a 9 pulgadas por encima de la parte superior del barral Pele 1 2 cm del aislamiento en cada extremo del cable Figura 7 NOTA Se deben revisar todos los tornillos de fijación y volver a ajustarlos cuando sea necesario antes de realizar la instalación 6 Vuelva a coloca...

Page 27: ... bien asentada contra la caja de salida Si la caja de salida está empotrada retire el panel hasta que la abrazadera haga contacto con la caja Si la abrazadera y o la caja de salida no están bien aseguradas el ventilador podría tambalearse o caerse ADVERTENCIA No conecte las aspas hasta que el ventilador esté totalmente instalado Instalar el ventilador con las aspas colocadas podría ocasionar daños...

Page 28: ... conectores excepto el conductor con conexión a tierra No opere el ventilador hasta que las aspas estén instaladas Podría ocasionar ruidos y daños al motor 3 Una vez que se ha haya realizado la conexión deslice el receptor en el soporte del colgador teniendo cuidado de no pillar los cables Figura 4 PRINCIPAL CAJA DE FUSIBLES x 3 Aditamentos utilizados Conectores de cable 1 Conecte los conductores ...

Page 29: ...RTENCIA ADVERTENCIA No utilice este ventilador con un controlador variable de pared Rheostat o un regulador de intensidad Si lo hiciera podría dañar la unidad del mando a distancia del ventilador de techo Solo para referencia visual no ha sido diseñado para cubrir todos los tipos de controles PRINCIPAL CAJA DE FUSIBLES Cómo utilizar su ventilador de techo Figura 2 Figura 1 Cómo instalar la carcasa...

Page 30: ...de el ventilador y disminuye la velocidad Enciende el ventilador y aumenta la velocidad 3 Para que el ventilador sea functional instale las pila continuación siga el proceso de fijación remota de código Si no se utiliza el ventilador durante un largo periodo de tiempo extraiga la batería para evitar cualquier daño alejado del calor o la humedad excesiva Figrua 3 Interruptores de DIP Configurar Bat...

Page 31: ...e la pared Figura 1 Fije la placa de la pared usando los dos tornillos suministrados 31 Figura 7 Cómo utilizar su ventilador de techo cont Interruptor del Reversa 7 Si se desea que el flujo del aire vaya en la dirección opuesta apague el ventilador y espere a que se detengan las palas Deslice la carcasa de la cubierta para visualizar el interruptor del reverso Deslice el interruptor del reverso ub...

Page 32: ...n método de control alternativo 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fijación y la tuerca del soporte de barral están flojos 2 El tornillo de fijación en la unidad del barral de la semiesfera está flojo 3 El soporte de suspensión o la caja de distribución eléctrica del techo no están bien asegurados 1 Ajuste bien los dos tornillos de fijación y las tuercas en el soporte de barral 2 Aj...

Page 33: ...lador Póngase en contacto con su tienda para obtener las piezas de repuesto ADR1 45BL P626018BL AP1115BL AP626007 AMA6260 RECAN6260 TR400 AP255BL AP260BL HDWFP6260 33 Cubierta de unión del motor Unidad del motor del ventilador Unidad del soporte de suspensión Unidad del barral de la semiesfera Capuchón de techo Cubierta para el tornillo del capuchón Modelos N Descripción N de Ref Pieza N FP6260 Li...

Page 34: ...10 NOTA 34 Figura 1 1 2 3 4 5 6 8 Pickett Drum 10 9 7 Modelo N º FP6260 Ilustración del despiece ...

Page 35: ......

Page 36: ...tro sitio Web en www fanimation com 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Copyright 2017 Fanimation 2017 02 V 01 ...

Reviews: