background image

F&F Filipowski sp. j.

Konstantynowska 79/81   95-200 Pabianice   

phone/fax: (+48 42) 215 23 83 / 227 09 71    POLAND

http://www.fif.com.pl   e-mail: [email protected]

WARRANTY.

  The  F&F  products  are 

covered by a warranty of the 24 months   
from the date of purchase.  Effective only 
with proof of purchase. 
Contact your dealer or directly with us. 
More  information  how  to  make  a  com-
pliant can be found on the website:
www.fif.com.pl/reklamacje

Do not dispose of this device in the trash along with other waste! 

According 

to the Law on Waste, electro coming from households free of charge and can 
give any amount to up to that end point of collection, as well as to store the 
occasion of the purchase of new equipment (in accordance with the principle 
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned 
in nature, pose a threat to the environment and human health.

TEMPERATURE CONTROLLER

RT-825

- 1 -

- 2 -

Purpose

Description of the external panel 

Functioning

The  RT-825  temperature  controller  is  designed  for  direct  control  of 
heating devices powered by 230 V with maximum current no higher 
than 16 A.

The  controller  can  operate  in  one  of  four  operating  modes:
- operation with an internal temperature sensor
- operation with an external temperature sensor (included)
- operation with two temperature sensors
- operation in "timer” mode
When the room temperature falls below 2°C from the temperature set 
in the controller, the heating device switches on (

         

symbol on the 

display).  When  the  room  temperature  is  higher  than  the  set 
temperature, the heating device will be disconnected. If the controller 
operates in "0" mode,   with two external and internal temperature 
sensors (parameter F3)

 

and the temperature in the room exceeds the 

Programming

Press the MENU button to enter the programming mode. In the 
programming mode you can set 8 parameters. Use the UP/DOWN 
buttons to choose one of the parameters. Press ON/OFF button to 
edit a parameter. Change the value of the parameter in the para

-

meter  edit  mode  using  the  UP/DOWN  buttons.  Confirm  setting 
with the ON/OFF button.

Parameters

F1  -  set  the  time  for  automatic  switching-on  of  the  controller. 

Minimum setting - 1 h.

F2  -  set  the  time  for  automatic  switching-off  of  the  controller. 

Minimum setting - 1 h

F3 - set the operating mode for the temperature sensors:

1 - operation with an internal temperature sensor

2 - operation with an external temperature sensor (included)
3 - operation with two temperature sensors (default setting)

F4 - set the time: week, hour, minute
F5 - set the upper threshold of the temperature protection in the 

range of 40°C  to  70°C with increments of 1°C (factory setting: 
50°C).  It  works  only  in  the  mode  of  operation  with  two 
temperature sensors.

F6 - set the antifreeze protection in the range of  2°C to 10°C with 

increments of 1°C (factory setting: 3°C).

F7  -  set  temperature  correction  in  case  there  is  a  difference 

between  temperature  indication  from  the  controller  and 
actual temperature in room. The correction can be adjusted 
within ±5 °C with increments of 0.1 °C.

F8 - set the weekly program of temperature regulation in a room 

according to the time of day a

n

d divided into working days, 

Saturday and Sunday.

Set the weekly program of controller operation (F8)
Every  day  in  the  controller  program  is  divided  into  four  parts 

marked with icons:

         - morning
         - forenoon (leaving the house)
         - 

afternoon, evening (coming back)

         - night

It is necessary to set the start time for each of these periods (the 
hour of the end of the given period is the starting time of the next). 
The start times for each time of the day should be set separately for 
business  days,  Saturdays  and  Sundays.  Temperature  value  is 
programmed for each time of day.
The following weekly program of the controller operation is set:

5

9 0 8 3 1 2

5 9 2 6 2 4

MENU

88.

8

°C

ROOM outside

°C

88 88

ON

OFF

ON/OFF

UP

DOWN

time of day 

indication

temperature

indicator

clock

indication of the 

antifreeze mode

timer OFF/ON 

indication

heating activation 

indication

internal/external

probe

value  set  in  parameter  F5,  the  heating  device  will  be  discon

-

nected.  On  the  other  hand,  if  the  temperature  falls  below  the 
value set in parameter F6 (antifreeze mode), the heating device 
will be switched on, whether the controller is on or off.

Timer  mode operation

The  "timer"  function  operates  in  a  cyclic  mode  starting  from 
switching on the controller for the set time (parameter F1), and 
then  the  controller  will  be  switched  off  for  the  set  time 
(parameter F2) etc. on all days of the week. The activation time of 
the controller starts when the number of hours is accepted with 
the  ON/OFF  key.  When  the  "timer"  function  is  activated,  the 
temperature control is maintained depending on the settings.

"

"

UP/DOWN button
Short press of the button during normal operation decreases or 
increases the value of set temperature by one degree.

MENU button
Short press of the button switches the device to the programming 
mode.

ON/OFF button
Long press of the button switches the controller on or off (about 
2 seconds).

- 3 -

- 4 -

Time of day

Time of day

start

Value of the 

set temperature

MON-FRI

SAT, SUN

06:00 - 08:00

08:00 - 16:00

16:00 - 22:00

22:00 - 06:00

06:00

08:00

16:00

22:00

25

10

25

15

25

10

25

15

Summary of Contents for RT-825

Page 1: ...ss of brand Electro thrown in the trash or abandoned innature poseathreattotheenvironmentandhumanhealth TEMPERATURE CONTROLLER RT 825 1 Purpose Functioning The RT 825 temperature controller is designed for direct control of heating devices powered by 230 V with maximum current no higher than16A The controller can operate in one of four operating modes operation with an internal temperature sensor ...

Page 2: ...ntifreeze mode the heating device willbeswitchedon whetherthecontrollerisonoroff Timer modeoperation The timer function operates in a cyclic mode starting from switching on the controller for the set time parameter F1 and then the controller will be switched off for the set time parameter F2 etc on all days of the week The activation time of the controller starts when the number of hours is accept...

Page 3: ...eratingmodeforthetemperaturesensors 1 operationwithaninternaltemperaturesensor 2 operationwithanexternaltemperaturesensor included 3 operationwithtwotemperaturesensors defaultsetting F4 setthetime week hour minute F5 set the upper threshold of the temperature protection in the range of 40 C to 70 C with increments of 1 C factory setting 50 C It works only in the mode of operation with two temperat...

Page 4: ...gram is divided into four parts markedwithicons morning forenoon leavingthehouse afternoon evening comingback night It is necessary to set the start time for each of these periods the hour of the end of the given period is the starting time of the next Thestarttimesforeachtimeofthedayshouldbesetseparatelyfor business days Saturdays and Sundays Temperature value is programmedforeachtimeofday Thefol...

Page 5: ...ne so there is no option to set the ending time of the givenperiod 6 Use the UP DOWN buttons to set the desired temperature for this time of day morning The temperature can be changed every 1 C in the range of 5 55 C Confirm with the ON OFF button 7 Once the temperature value has been confirmed the program automatically returns to step 4 allowing to set the parameters of thenexttimeofday 8 After s...

Page 6: ...oller mode of operation from automatic to manual and vice versa day time icon goesoff Manual operation room temperature control is based on the cur rentsetting UsetheUP DOWNbuttonstochangethetemperature Automaticoperation thetemperatureismaintainedonthebasisof thepre programmedcyclesofthecontroller Temperaturereadout If the controller is set to operate with two temperature sensors by short press o...

Page 7: ...scheme probe N L 1 2 3 4 5 6 OUT N heater 1 4 outputforheaterconnection 2 Lpowersupplyofthecontroller 3 Npowersupplyofthecontroller 5 6 outputfortemperatureprobeconnection Take special care when installing the controller Incorrect connection may result in electric shock and or damage to thecontrollerandthepowereddevice Donotinstalladevicethatisdamagedorincomplete Do not install the device in rooms...

Page 8: ...ns front 86 86 mm D 22 mm back 6 27 5 mm mounting external temperature sensor NTC sensor dimensions Ø7 Ø 0 D in flush mounted ingress protection IP20 Ø60 h 25 mm sensor isolation PC muff wire PC 2 0 34 mm l 3 m 3 Remove the cover and the frame of the controller taking care not todamagetheelectronicsofthecontroller 4 Connectaccordingtothescheme 5 Place the bottom part of the controller in the flush...