LM.60i
7. Display
A5911664 - GB 100503
15
6.
Standstill position whereby control is determined by the remote
control.
7.
Actuator is in standstill against a limit switch.
U.
Due to a problem LM.60i is now controlling based on the pre-
defined position
L.
As the IO-net has failed, the LM.60i is now controlling
independently based on its own temperature measurements
and the settings made earlier.
The flashing dot on the display indicates that the intelligent module is
functioning normally and is being powered by a regular 24VAC source.
7.1.3. Alarms
An “
A
” in the display, alternated by a figure indicates an alarm. The table
below contains an alarm overview.
Alarm
indication
Meaning
A0
Backup alarm: No settings available,
adjusting necessary
!
(
via IO-net A100
)
A1
Memory defect.
A2
Inlet position not reached within 10 min.
A3
Power failure, system controls based on emergency power
supply.
A4
No IO-net communication.
A5
Battery test indicates error.
A6
Current limiting activated
Note 1: Clear a cancelled alarm by pressing the key in the print.
Note 2: A control computer connected to the LM.60i via I/IO-net, can adopt
the alarm message, provided this feature is supported.