![Fancom F41 Instruction Manual Download Page 22](http://html.mh-extra.com/html/fancom/f41/f41_instruction-manual_542059022.webp)
Lumina 41/42
Weigher and Transport
18
In the weigher menu enter the basic data for the weigher used. In the transport menu enter the transport settings.
Installer
WEIGHER/TRANSPORT/EXTERN.REGIST.
Installer
WEIGH/TRANSP.
WEIGHER
tab page
General
Type weigher
Setting of the type of weigher used. The “WU.70” and “POLY” are the standard Fancom
weighers.
If one of these weighers is selected, the feed computer automatically knows most of the
standard settings. The data belonging to “OTHER” can be entered manually.
Dosing out relay
Setting of the address of the dosing out relay which controls the outlet.
Reverse relay
*
Setting for the analog output address (choice
LINEAR
) or relay output (choice
RELAY
).
Weigher input address
Setting of the input address to which weighing is connected. This input converts a
weighing signal into counts. The computer converts the counts into a weight.
Address 0 is a built in address and address 1..30 is an external weighing card.