Aura 70

 

Technical specifications Aura 70 + Switchbox 

 

 

 

25 

 

 

 

Standard (L1, L2, L3) 

 

1.  Silo 1 auger motor 

2.  Silo 2 auger motor 

3.  Chain drive motor or 

chain drive motor with 
softstarter   

US Variant 

 

 

1.  Silo 1 auger motor 

2.  Silo 2 auger motor 

3.  Chain drive motor or 

chain drive motor with 
softstarter   

Summary of Contents for AURA 70

Page 1: ...g...

Page 2: ...duced by Fancom For the latest information about product installation and operation please contact the customer service dept and or the technical service dept of the Fancom concerned In spite of the c...

Page 3: ...7 4 User settings 8 4 1 Overview 8 4 2 Feeding times 8 4 3 Circuit times 9 4 4 Registration 9 5 Alarm 10 5 1 Alarm overview 10 5 2 Alarm settings 13 5 3 Alarm history 13 6 Installing the Aura 70 14 6...

Page 4: ...uggestions Note providing recommendations and additional information Warning indicating damage to the product if you do not follow procedures carefully Warning indicating danger to humans or animals E...

Page 5: ...remedied by an authorized installer Only replace a defective fuse by a fuse of the same type see connection diagram Inspect the control computer regularly for any damage Report any damage to your inst...

Page 6: ...lling process starts the dispensers will open and the feed will fall into the troughs Filling the dispensers when the filling process starts the dispensers will be filled first The basic components of...

Page 7: ...combination with dispensers The chain will start first to dose the feed into the dispensers After a settable wait time the silo auger starts to filling the circuit until the feed return sensor detects...

Page 8: ...ime sections can be inspected and dispensers can be adjusted per animal After the wait time the system starts the circuit filling process The chain will start first to dose the feed into the dispenser...

Page 9: ...be operated on the touch screen 1 Touch screen 2 Silo 1 control switch 3 Silo 2 control switch 4 Circuit control switch automatically switch off in case of a chain break 5 Dosator control switch The c...

Page 10: ...ble menus and an alarm indicator to navigate to more details Only data important to you will appear on your control computer This has been set in the installation menus This chapter explains all the m...

Page 11: ...s used 4 Return feed sensor If the return feed sensor detects feed it will stops the silo auger from filling the circuit 5 System full sensor If the chain is full the symbol light up green and the sys...

Page 12: ...le Readout of the circuit number Readout of the run time of today Readout of the run time of yesterday Readout of the run time of the day before yesterday Readout of the total run time To reset the va...

Page 13: ...arm which has been recovered The controller switches off the alarm but the alarm status remains visible Alarm disabled switch off the alarm entirely Only do this when houses are unoccupied Do not forg...

Page 14: ...thin the set time Check the sensor and adjust the delay setting if necessary Return feed sensor Signal actual time not set Check and adjust time if necessary Power failure Signal when starting up afte...

Page 15: ...alarm situation 3 Press once more The alarm message will disappear and the alarm status changes into Alarm temp off followed by Alarm stand by If the alarm is disabled the control computer will not g...

Page 16: ...ra 70 Alarm 13 Max runtime circuit Setting of the maximum runtime hours minutes One setting for all circuits The control computer stores the alarm history The computer stores the last six alarm messag...

Page 17: ...er pipes drainage pipes etc Never mount the Aura 70 in a humid and or dusty room and certainly not in the room where the animals are present Mount the Aura 70 at such a height that you can control the...

Page 18: ...of moisture dust and or aggressive gasses Check that the mains voltage and frequency for which this computer is suitable correspond to the mains voltage and frequency on site Be sure that the Aura 70...

Page 19: ...a dipswitch is used to terminate the control computer Example Setting the terminal resistor FNet Four control computers connected using FNet Control computers 1 and 4 are at the end of the network The...

Page 20: ...net by several computers activating simultaneously Fancom advises always entering a computer number Computer name Setting of the name of the control computer Temperature unit Setting of the unit of te...

Page 21: ...mber of transmitted messages Sent counter and readout of the number of received messages Receive counter no PC messages These counters can be used to trace faulty communication connections In this cas...

Page 22: ...eeding times Setting of the number of feeding times for all circuits maximum 24 Dosator relay Setting of the output address of the dosator NO Rel 2 AO 1 Start with Setting of the start situation Filli...

Page 23: ...ern alarm 2 and Extern alarm 3 are free to use Extern alarm input 1 2 3 Setting of the input address of the external alarm NO DI NC DI NO Overview of the relays analog inputs analog output and digital...

Page 24: ...limate Operating temperature range 0 C to 40 C Storage temperature range 10 C to 50 C Relative humidity 95 uncondensed Aura 70 I O board 7 analog inputs Used as digital input Status high is R 150 Stat...

Page 25: ...Aura 70 Technical specifications Aura 70 Switchbox 22 1 Aura board 2 Powerboard FCA 1 Silo switch 1 2 Silo switch 2 3 Chain switch with softstarter optional...

Page 26: ...23 1 IO Net 2 IO Net 3 Fnet 1 4 Fnet 1 5 Fnet 2 6 Fnet 2 7 SD Card 1 AI1 System full sensor 2 AI2 Dosator close input external start 3 AI3 Return feed sensor 4 AI4 Silo switch over sensor 5 AI5 Exter...

Page 27: ...ver NC 5 Dosator motor 240V N 6 Dosator motor 240V Open 7 Dosator motor 240V Close N Power supply L1 Power supply L2 Power supply L3 Power supply US variant 1 2 Chain break NC 3 4 Chain drive safety s...

Page 28: ...Switchbox 25 Standard L1 L2 L3 1 Silo 1 auger motor 2 Silo 2 auger motor 3 Chain drive motor or chain drive motor with softstarter US Variant 1 Silo 1 auger motor 2 Silo 2 auger motor 3 Chain drive mo...

Page 29: ...lace Panningen the Netherlands Hereby declares that Aura 70 Satisfies the conditions of 1 The Low Voltage Directive 2014 35 EU according to EN 61010 2 the EMC Guideline directive 2014 30 EU Emission a...

Reviews: