Aura 70
Alarm
10
The Aura 70 displays the alarm overview by pressing
. There are two types of alarm:
1.
Loud alarm
: An active loud alarm sounds a siren, shows an alarm message and a report on the screen. This
type of alarm has a
high priority
.
2.
Silent alarm
: An active silent alarm shows an alarm message and a report on the screen. This type of alarm
has a
low priority
.
Status
Readout / setting the alarm status:
Alarm stand by
: no alarm (stand by mode).
Alarm recovered
: there was an alarm which has been recovered. The controller
switches off the alarm, but the alarm status remains visible.
Alarm disabled
: switch off the alarm entirely. Only do this when houses are
unoccupied. Do not forget to reset the status to Alarm stand by.
Alarm temp. off
: switch off the current alarm. When the alarm situation has been
cancelled, this status will automatically become Alarm stand by. Always check
that the status has reverted to Alarm stand by.
Silent alarm
: alarm message shown on display only.
Alarm
: the type of alarm is shown on the display.
Alarm test
: test the alarm and after reset the status will be changed to Alarm
stand by.
Message
Readout of the alarms (see table below).
Summary of Contents for AURA 70