INSTALLER: 5. System settings
9
5.3.2
Silo
Relay output
Enter the address (in front of the point) and the relay number (behind the
point) to which the silo auger has been connected.
Status
The silo auger status: OFF (silo auger not active) or ON (silo auger active).
Wait time inc.
Enter within how many minutes and seconds after dosing in has started the
weigher content must increase.
Min.inc./30sec
Enter the minimum weigher content (kg) increase each 30 seconds during
ingredient dosing in. The maximum dosing in time per ingredient is 10
minutes (600 seconds). If the weigher capacity is set to a value greater than
600 kg, the maximum dosing in time per ingredient is equal to the weigher
capacity in seconds. Example: a weigher capacity of 1200 kg equals a
maximum dosing in time of 1200 seconds per ingredient.
After flow
When dosing in has stopped certain ingredients can still fall into the weigher
(after flow). This after flow is a computer calculated value. When the 743 is
started the after flow is 0.0kg. Enter an (estimated) after flow for the first
time the 743 is put into operation.
Wait aft. dos. in
Enter here how long (minutes and seconds) the computer should wait after
an ingredient has been dosed in before determining a stable weight.
5.3.3
Additive
Relay output
Enter the address (in front of the point) and the relay number (behind the
point) to which the dosing in mechanism for this additive has been
connected.
Status
Status
shows if an additive is currently being added (ON) or not (OFF).
Pulse input
Enter the address (in front of the point) and the digital input number (behind
the point) to which the pulse giver (when dosing in is based on pulses) for
this additive has been connected.
>>Additive_1
Relay output 0. 0
Status OFF
Pulse input 0. 0
next additive (max. 4 additives)
previous additive
2×
>>Silo_1
Relay output 0. 0
Status OFF
Wait time inc. 0:00
Min.inc./30sec 0.0
After flow 0.0
Wait aft.dos.in 0:00
next silo (max.12 silos)
previous silo