INSTALLING THE FAN

 

INSTALLING THE DOWN ROD 

1.  Remove the ball joint and dowel pin from the down rod (5) by loosening the set screw (3). 

Do not discard keep these parts, they are required to reassemble later. 

2.  Feed the wires (2) and plug (1) through the down rod (5). 
3.  Insert the down rod into the 

down rod housing 

(7). Align the 

down rod housing 

hole with the down rod 

hole.   
Insert the pin (8) into the hole and secure with the pin spring lock (9).   

4.  Secure the down rod (5) and 

down rod housing 

(7) by tightening the two set screws (10) on the 

down 

rod housing

 (7). 

5.  Install the 

down rod housing cover 

(6) over the 

down rod housing

 (7).   

6.  Slide the canopy (4) over the down rod (5). 
7.  Install the ball joint and dowel pin back onto the down rod (5) and secure by tightening the set screw 

(3). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HANGING THE FAN 

Lift the fan assembly onto the mounting bracket. Ensure the key slot (A) of the hanger ball is positioned 
on the key pin (B) of the mounting bracket (C) to prevent the fan from rotating when in operation. (Fig.5) 

 

 

 

 

 

 

 
 
 
Insert the LED driver into the lower section of the mounting bracket then insert the remote receiver into 
the top section of the mounting bracket. Fig.6   

   

 

Fig. 4 

Fig. 5 

Fig. 6 

Summary of Contents for EVO1 - PREVAIL

Page 1: ...8 2019 FANAWAY EVO1 LED CEILING FAN WITH DIMMABLE AND COLOUR SHIFTING LED LIGHT INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION ...

Page 2: ... is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety 3 Children should be supervised to ensure that they do not play with the appliance 4 An all pole disconnection switch must b...

Page 3: ...st 2 3 m above the floor in Europe or 2 1 m above the floor in Australia 8 This fan is suitable for indoor use only Mounting the fan in a location where it is subject to water or moisture is dangerous and may increase the risk of damage injury or electrical shock and will void the warranty 9 Must be assembled and installed by a licensed electrician 10 WARNING If unusual wobbling or oscillating mov...

Page 4: ... ceiling fan has been damaged during transport Do not operate install any product which appears damaged in any way Return the complete product to the place of purchase for inspection repair or replacement Examine all parts you should have the following 1 Mounting bracket x 1 10 Retraction mechanism x 1 2 Canopy screws x 4 11 Lamp base x 1 3 Canopy x 1 12 LED board x 1 4 Down rod x 1 13 Lamp shade ...

Page 5: ...is capable of carrying a load of at least 50kg with the two long screws provided Ensure at least 30mm of the screw is threaded into the support Fig 2 NOTE The bracket screws provided are for use with wooden structures only For structures other than wood the appropriate screw type MUST be used Ensure the screws used are suitable for the mounting surface and the surrounding environment ANGLED CEILIN...

Page 6: ...own rod 5 and down rod housing 7 by tightening the two set screws 10 on the down rod housing 7 5 Install the down rod housing cover 6 over the down rod housing 7 6 Slide the canopy 4 over the down rod 5 7 Install the ball joint and dowel pin back onto the down rod 5 and secure by tightening the set screw 3 HANGING THE FAN Lift the fan assembly onto the mounting bracket Ensure the key slot A of the...

Page 7: ...he two slot screws 2 with the keyhole slots of the lamp base 4 4 Turn the lamp base counterclockwise until the slot screws are firmly at the end of the slots 5 Secure screw 1 back to the base bracket Tighten all three screws Do not over tighten 6 Connect the female plug 1 from the fan to the male plug 1 on the LED board 2 Fig 8 7 Install the lamp shade 5 back onto the lamp base 4 by turning it clo...

Page 8: ...rical wiring at the mounting bracket terminal block A a Connect the remote receiver C power input wires and fixed wiring via the 4 port quick connector 1 b Connect the LED driver D power input wires and remote receiver C power output wires via the 2 port quick connectors 3 c Connect the LED driver D PWM signal input wires and remote receiver C PWM signal output wires via the 3 port quick connector...

Page 9: ...he terminal block on the mounting bracket Cover the mounting bracket with the canopy Ensure all electrical wiring is tucked inside the canopy and that the wires are not damaged during this step Secure the canopy to the hanger bracket using the screws provided Fig 10 Switch ON mains power supply to the fan Test the fan operations or enjoy using the fan following instructions the under USING YOUR CE...

Page 10: ...d insert 2 x AAA batteries Ensure the polarities are correct as shown in the battery compartment Batteries included Fig 11 The remote transmitter and receiver must be configured so that communication between each other is paired up This is achieved by setting the DIP switches on the remote Fig 11 and receiver Fig 12 are on the same settings Fig 13 NOTE There are 4 DIP switches which can be setup t...

Page 11: ... following order 3000K 5000K 4000K 3000K 7 Press the button to turn the light ON OFF Press and hold the button to access the light dimming function The remote has memory function So if the fan or light is turned off by the isolating switch it will memorise the settings and when turned back on it will use the same settings REVERSING SWITCH Your ceiling fan can operate in either summer or winter mod...

Page 12: ...d in the electricity for off peak hot water control may cause a change in fan motor noise This is normal Please allow a 24 hour settling in period most noises associated with a new fan disappear during this time The manufacturer s warranty covers actual faults that may develop and NOT minor complaints such as hearing the motor run All electric motors are audible to some extent CARE CLEANING NOTE A...

Page 13: ...e of the battery Regularly check the product and make sure the battery box lid is correctly secured If the battery compartment does not close securely stop using the product and keep it away from children If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical attention If you suspect your child has swallowed or inserted a button battery immedi...

Page 14: ...nce using inappropriate cleaning products E Defects caused by normal wear and tear accident negligence alteration or misuse F A product dismantled repaired or serviced by any serviceman other than an authorized employee or agent of Fanaway G Product installed by an unqualified person Must be a qualified electrician in Australia H Damage or defects caused by fans being installed externally FANS ARE...

Page 15: ...a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure CONTACTS Contact Lucci Warranty Service Hotline acting as the service agent for Fanaway on 1800 602 243 between 9AM and 5PM E S T...

Reviews: