Fält Communications 2016 ©
162187 Manual Fältcom ECII® Flex V024D 2016-02-23
Page 19 of 41
From phone:
002 #
Test of Sequence Receivers (alarm receiver) 3-6
When this sequence is programmed the Fältcom ECII calls Alarm Receiver 3-6 after leaving
programming mode.
From keypad:
<
-
>
From phone:
00 < 3-6 > #
Priority order for test of receiver
When setting a test of alarm receiver the test will be queued internally in the Fältcom ECII®
Flex. When leaving programming mode the Fältcom ECII® Flex will start the test of alarm re-
ceivers and call in the following priority order:
1. Alarm Receiver 1
2. Alarm Receiver 2
3. Sequence Receiver 3
4. Sequence Receiver 4
5. Sequence Receiver 5
6. Sequence Receiver 6
7. Test alarm/Routine call receiver
8. Technical alarm receiver
9. Information alarm receiver
6.10 Change of time delay for alarm button
The delay time on the alarm button can be set to between 1 and 30 seconds. The default time
is 5 seconds.
From keypad:
< 1-30 >
From phone:
053
< 1–30 > #
Note: The delay programmed is the time until the alarm is activated by the Fältcom ECII®
Flex. It will take an additional two seconds before the alarm is called out because of the start-
up time and latency in the PSTN.
6.11 Connections to telephone line with automatic dial/
connection.
If the Fältcom ECII® Flex is connected to a telephone line with automatic dial or automatic
connection; where the telephone exchange directs the call without the user entering any keys,
a pause must be added to prevent the Fältcom ECII® Flex from calling out. One
– symbol
represents a pause of two seconds. There is no need to program any telephone number since
the telephone exchange takes care of that.
From keypad:
From phone:
001
#