6.3 Reset to factory settings
This function will reset the Fältcom ECII® Flex to its default settings; clearing all programmed
receivers, codes and settings; all but Alarm Code 1 which is default set to ‘1’.
Note: Reset to default setting will not erase speech messages. See section about speech
messages for information on how to erase speech messages.
From keypad:
From phone:
990 #
6.4 Clear all active alarms
This function will clear all active alarms on the Flex. It will not remove receivers or codes, but
it will make the Flex stop calling out an alarm, without an acknowledgment of that alarm. Any
new alarm input made after this will be handled normally.
From keypad:
From phone:
992 #
6.5 Change of PIN code
For entering programming mode remotely from a telephone a PIN code is needed. This is
default “1111”, but can be changed by the following:
From keypad:
< old PIN>
< new PIN >
< new PIN>
From phone:
900
< old PIN >
< new PIN >
< new PIN > #
6.6 Alarm receivers and alarm codes
Six different alarm receivers can be programmed. Alarm receivers 1 and 2 have separate
alarm codes and receivers 3-6 use the alarm code for receiver 1. If alarm receiver 2 is pro-
grammed, but not alarm code 2; receiver 2 will use alarm code 1 when dialing.
If the alarm receiver is an alarm centre the centre will provide an alarm code. Program the
alarm code to the correct alarm receiver number. If the alarm receiver is a standard telephone
or a mobile choose your own alarm code. There must always be an alarm code programmed
in order for the Fältcom ECII® Flex to call the receiver.
Note: Alarm Code 1 is default set to ‘1’.
1.
If required, reset to factory settings:
From keypad:
From phone:
990 #
2.
Enter phone number for Alarm Receiver 1: