background image

INSTALLATION  MANUAL

falmecau.com

Milano
Genova 120

Summary of Contents for MILANO+

Page 1: ...INSTALLATION MANUAL falmecau com Milano Genova 120...

Page 2: ...REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES...

Page 3: ...4 Duct Clamps x4 5 200 mm Flexi Duct 5 Meters Length 6 White Stainless Steel Wall Eave Vent OPTION 2 EXTERNAL HOOD SOLUTION Fig B Models include ER 765 ER 1140 and ER 2010 Unit designed to be mounted...

Page 4: ...4 512 822 250 505 815 541 851 12 379 665 358 184 541 851 280 118 200 280 247 332 204 MILANO 56 87 FP3ML60S2 FP3ML90S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Page 5: ...5 851 1137 12 815 1101 98 351 584 870 360 118 0 0 2 851 1137 824 1110 330 360 326 326 248 204 MILANO 87 116 DEEP FP3MLD90S2 FP3MLD12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Page 6: ...6 1137 12 1101 98 351 870 450 118 0 0 2 1137 1110 420 450 326 416 281 204 GENOVA 116 FP3GV12S2 EN HOLE MEASUREMENTS FOR INSTALLATION IT MISURE FORO PER INCASSO...

Page 7: ...7 600 650 mm 2 STEP 1 Minimum distance by cooktop STEP 2 Wall unit hole STEP 3 You push the hood in wall unit hole 3 1...

Page 8: ...N TOP DUCTED POSITION 2 3 1 ATTENTION ONLY ON MILANO DEEP 3 x4 CAUTION CAUTION 10 28 mm 5 5a 4 STEP 4 You screw the blocking devices STEP 5 Connect the hood outlet in the top or back ducted position t...

Page 9: ...5 4 ATTENTION ONLY ON MILANO 87 DEEP FOR BACK DUCTED POSITION 5 4 ATTENTION ONLY ON MILANO 87 DEEP 2 3 1 5b 5c 6 7 STEP 6 Attach the male plug of the rangehood unit to the main power supply STEP 7 As...

Page 10: ...10 2 1 9 8 10 STEP 8 Remove the metal filters STEP 9 Remove the cover caps STEP 10 With your finger enter the hole and pull the lever to unlock the stop SEQUENCE FOR REMOVING THE HOOD...

Page 11: ...hat the electrical mains power supply corresponds with what is report ed on the identification plate located inside the hood If the supply cord is damaged it must be replaced by the manufacturer its s...

Page 12: ...harge of air must be fulfilled INSTALLATION only intended for qualified personnel Before installing the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technica...

Page 13: ...t on and off Long impulse change light tone from 2700K to 5600K SENSOR FUNCTION AVAILABLE ONLY ON MILANO 87 DEEP 1 2 3 4 5 6 TIMER red LED flashing Auto switch off after 15 min The function deactivate...

Page 14: ...ufacturer declines all responsibility for failure to comply with these in structions CLEANING OF INTERNAL SURFACES Do not clean electrical parts or parts related to the motor inside the hood with liqu...

Page 15: ...ty The external and in roof motors unit should be checked regularly to ensure that nothing is obstructing the air flow from the housing We also recommend a routine inspection of the remote units every...

Page 16: ...ulled tight and excess removed IN ROOF MOTOR SOLUTION 765 1140m3 h 1 Fan power supply attached to internal hood unit 2 200mm flexi duct installed between rangehood and motor inlet 3 200mm flexi duct i...

Page 17: ...xtension lead not supplied of up to five meters may be added if required EXTERNAL ROOF SOLUTION METAL ROOF INSTALLATION Inspection Ensure the unit has arrived in good condition and that the impeller w...

Page 18: ...e replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard EXTERNAL WALL SOLUTION Inspection Ensure the unit has arrived in good condition and that the...

Page 19: ...19 ENGLISH 518 147 450 419 123 360 EW 765 EW 1140 SPECIFICATIONS EW 2010 SPECIFICATIONS 130 80 162 5 325 298 6 5 4 holes 425 388 6 5 4 holes 170 80 212 5 All measurements in mm All measurements in mm...

Page 20: ...the appliance location and return Any travel in excess of 50 km each way is not cov ered by the warranty PRKS has a service network in all metropolitan areas and most regional areas Where the warranty...

Page 21: ...21 NOTE NOTES...

Page 22: ...22 NOTE NOTES...

Page 23: ...23 NOTE NOTES...

Page 24: ...Code 110033077 Ed 05 2019...

Reviews: