FALMEC LUMEN 90 NRS Instruction Booklet Download Page 16

16

17

ENGLISH

kept together with the equipment for any future 

consultation.

If the equipment is sold or transferred to another per-

son, make sure that the booklet is also supplied so 

that the new user can be made aware of the hood's 

operation and relative warnings. 

After the stainless steel hood has been installed, it 

will need to be cleaned to remove any residues re-

maining from the protection adhesive as well as any 

grease and oil stains which, if not removed, can cause 

irreversible damage to the hood surface. To properly 

clean the unit, the manufacturer recommends using 

the supplied moist wipes, which are also available 

sold separately. 

Insist on original spare parts.

INTENDED USE

The equipment is solely intended to be used to 

extract fumes generated from cooking food in 

non-professional domestic kitchens: any other 

use is improper. Improper use can cause damage 

to persons, things, pets and exempts the Manu-

facturer from any liability.

The equipment can be used by children over the age 

of 8 and by persons with reduced physical, sensory 

and mental abilities, or with no experience or knowl-

edge, as long as they do so under supervision or after 

having received relative instructions regarding safe 

use of the equipment and understanding of the dan-

gers connected to it.

Children are not to play with the equipment. Clean-

ing and maintenance by the user must not be carried 

out by children without supervision.

USE AND CLEANING WARNINGS

Before cleaning or carrying out mainte-

nance operations, disconnect the equip-

ment by removing the plug or switching 

off the main switch.

Do not use the hood with wet hands or bare feet.

Always check that all electrical parts (lights, extractor 

fan) are off when the equipment is not being used. 

The maximum overall weight of any objects placed 

or hung (if applicable) on the hood must not exceed 

1.5 Kg.

Always supervise the cooking process during the use 

of deep-fryers: Overheated oil can catch fire.

Do not leave open, unattended flames under the 

hood.

Do not prepare food over an open flame under the 

hood.

Never use the hood without the metal anti-grease 

filters: in this case, grease and dirt will deposit in the 

equipment and compromise its operation.

Accessible parts of the hood can be hot when used at 

the same time as the cooking appliances.

Do not carry out any cleaning operations when parts 

of the hood are still hot.

There can be a risk of fire if cleaning is not carried out 

according to the instructions and products indicated 

in this booklet.

Disconnect the main switch when the equipment is 

not used for long periods of time.

If other appliances that use gas or other fu-

els are being used at the same time (boiler, 

stove, fireplaces, etc.), make sure the room 

where the fumes are discharged is well-ventilat-

ed, in compliance with the local regulations.

 INSTALLATION

  only intended for qualified personnel

Before installing the hood, carefully read the chapter 'SAFETY 

INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside the hood.

POSITIONING

The minimum distance between the highest part of the cooking equip-

ment and the lowest part of the hood is indicated in the installation in-

structions. 

Generally, when the hood is placed over gas cookers, the distance must be at 
least 65 cm (25.6''). However, according to of standard EN60335-2-31, the mini-
mum distance between the cooker and lower part of the hood can be reduced 
to the quota reported in the installation instructions.
Should the instructions for the gas cooker specify a greater distance, this must 
be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment 
(rain, wind, etc.).

ELECTRICAL CONNECTION

(only intended for qualified personnel)

Disconnect the equipment from electrical mains power supply be-

fore carrying out any operations on the hood.

Ensure that the wires inside the hood are not disconnected or cut:

in the event of damage, contact your nearest Servicing Department.

Refer to qualified personnel for electrical connections.

Connection must be carried out in compliance with the provisions of law 

in force.

Before connecting the hood to the electrical mains power supply, check that:
•  voltage supply corresponds with what is reported on the data plate located 

inside the hood;

•  the electrical system is compliant and can withstand the load (see the techni-

cal specifications located inside the hood);

•  the power supply plug and cable do not come into contact with tempera-

tures exceeding 70 °C;

•  the power supply system is effectively and properly connected to earth in 

compliance with regulations in force;

•  the socket used to connect the hood is within reach.
In case of:
•  devices fitted with cables without a plug: the type of plug to use is a ''stand-

ardised'' one. The wires must be connected as follows: yellow-green for earth-
ing, blue for neutral and brown for the phase. The plug must be connected to 
an adequate safety socket.

•  fixed equipment not provided with a power supply cable and plug, or any 

other device that ensures disconnection from the electrical mains, with an 
opening gap of the contacts that enables total disconnection in overvoltage 
category III conditions.

  Said disconnection devices must be provided in the mains power supply in 

compliance with installation regulations.

The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety 
regulations.

Summary of Contents for LUMEN 90 NRS

Page 1: ...FR MANUAL DE INSTRUCCIONES ES RU INSTRUKCJA OBS UGI PL HANDLEIDING NL MANUAL DE INSTRU ES PT BRUGSANIVSNINGER DK INSTRUKTIONSBOK SE OHJEKIRJA FI BRUKSANVISNING NO INSTRUCTIONS BOOKLET Silence NRS Lume...

Page 2: ...2 2 Lumen 90 30 kg 356 40 529 510 301 569 1079 480 898 480 1 5 0 118 LUMEN 90 NRS...

Page 3: ...3 3 Lumina 90 36 kg Lumina 120 41 kg 900 1200 480 55 355 530 max 510 353 300 450 600 118 300 150 115 LUMINA 90 NRS LUMINA 120 NRS...

Page 4: ...4 4 Plane 90 34 kg Plane 120 36 kg 900 1200 490 60 355 530 max 510 353 300 115 450 600 118 300 150 PLANE 90 NRS PLANE 120 NRS...

Page 5: ...ion FR Mesures pour l installation ES Medidas para la instalacion RU PL rodki monta owe NL Maten voor de installatie PT Medidas para a instalacao DK Mal for installation SE Installationsatgarder FI Mi...

Page 6: ...check valve installation 2 DE Befestigung der Abzugshaube 1 Installation des R ckschlagventils 2 FR Fixation de la hotte 1 installation du clapet anti retour 2 ES Fijaci n de la campana 1 instalaci n...

Page 7: ...ion du tube NRS ES Fijaci n del tubo NRS RU NRS PL Mocowanie rury NRS NL Bevestiging NRS PT Fixa o tubo NRS DK Fastg relse af NRS r r SE Fixering av NRS FI NRS putken kiinnitys NO Feste av NRS r r A D...

Page 8: ...exi n el ctrica 5 Montaje de la chimenea 6 7 RU 5 6 7 PL Po czenie elektryczne 5 Monta komina 6 7 NL Elektrische aansluiting 5 Montage schacht 6 7 PT Liga o el trica 5 Montagem da chamine 6 7 DK Elekt...

Page 9: ...Instalacja iltra w g lowo zeolitowego opcjo nalna NL Installatie zeoliet kool stoilter optie PT Instalacao iltro carvao zeo lito opcional DK Installation af zeolit kulilte ret valgfrit SE Installatio...

Page 10: ...a iltra w glowo zeolitowego opcjonalna NL Installatie zeoliet koolstoilter optie PT Instalacao iltro carvao zeolito opcional DK Installation af zeolit kulilteret valgfrit SE Installation kol zeolitilt...

Page 11: ...l en Ezenk v l meg kell felelnie a r di antisztatikus jellemz kre vonatkoz eur pai szabv nyoknak Az elsz v felszerel se el tt ellen rizze hogy a h l zati t pegys g megfelel e az egys g belsej ben tal...

Page 12: ...tr szei m g melegek T zvesz ly ll fenn ha a tiszt t st nem a jelen f zetben szerepl utas t sok s term kek seg ts g vel v gzik el TELEP T S csak k pzett szem lyzet r sz re Az elsz v felszerel se el tt...

Page 13: ...zi az elsz v automatikus kikapcsol s t 15 perc m k d s ut n MELYIK SEBESS GET V LASSZUK 1 sebess g fenntartja a tiszta leveg raml s t alacsony ramfogyaszt ssal 2 sebess g norm l haszn lati felt telek...

Page 14: ...ges kezel s t rt njen a k rnyezetre rtalmas anyagok elt vol t sa s biztons gos rtalmatlan t sa valamint az jrahasznos that nyersanyagok elt vol t sa rdek ben Ezeknek a term keknek a megfelel rtalmatla...

Page 15: ...ntry of use It must also comply with European standards regarding radio antistatic properties Before installing the hood check that the electrical mains power supply corresponds with what is report ed...

Page 16: ...are being used at the same time boiler stove fireplaces etc make sure the room where the fumes are discharged is well ventilat ed in compliance with the local regulations INSTALLATION only intended f...

Page 17: ...tions to prevent conden sation from flowing back into the motor the minimum required number of bends the minimum required length to avoid vibrations and reduce the suction per formance of the hood You...

Page 18: ...ssembling it LIGHTING PLANE NRS The range hood is equipped with high efficiency low consumption LED spot lights with an extremely long life span under normal use conditions Should the LED spotlight ne...

Page 19: ...19 71 NOTE NOTES MEGJEGYZ S MEGJEGYZ SEK Az let inspir lja...

Page 20: ...Vittorio Veneto Treviso Italy info falmec com falmec com Code 110031146 Ed 02 2022 Import r MULTIKOMPLEX BUDAPEST KFT A p raelsz v k szak rt je 1995 ta H 1211 Budapest Mansfeld P ter utca 27 Volt Baj...

Reviews: