FALMEC Laguna pannellabile Instruction Booklet Download Page 15

15

ENGLISH

ELECTRICAL CONNECTION

(only intended for qualiied personnel)

Disconnect the equipment from electrical mains power supply before carry-
ing out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.

Refer to qualiied personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.

Before connecting the hood to the electrical mains power supply, check that:

П  voltage supply corresponds with what is reported on the data plate located inside the 

hood;

П  the electrical system is compliant and can withstand the load (see the technical specii

-

cations located inside the hood);

П  the power supply plug and cable do not come into contact with temperatures exceed

-

ing 70 °C;

П  the power supply system is efectively and properly connected to earth in compliance 

with regulations in force;

П 

the socket used to connect the hood is within reach.

In case of:

П  devices itted with cables without a plug: the type of plug to use is a ''standardised'' one. 

The wires must be connected as follows: yellow-green for earthing, blue for neutral and 
brown for the phase. The plug must be connected to an adequate safety socket.

П 

ixed equipment not provided with a power supply cable and plug, or any other device 
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.

 

Said disconnection devices must be provided in the mains power supply in compliance 
with installation regulations.

The yellow/green earth cable must not be cut of by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.

FUMES DISCHARGE

EXTERNAL EXHAUST HOOD (SUCTION)

In this version the fumes and vapours are discharged outside through 
the exhaust pipe.
To this end, the hood outlet itting must be connected via a pipe, to an 
external output.

The outlet pipe must have:

П  a diameter not less than that of the hood itting.
П  a slight slope downwards (drop) in the horizontal sections to prevent condensation from 

lowing back into the motor.

П  the minimum required number of bends.

П  the minimum required length to avoid vibrations and reduce the suction performance of 

the hood.

  You are required to insulate the pipes if it passes through cold environments.
  In the presence of motors with 800m

3

/h or higher, a check valve is present to prevent 

external air lowing back.

Deviation for Germany:
when the kitchen hood is used at the same time as appliances that are powered by energy other 
than electricity, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar).

HOOD WITH INTERNAL RECIRCULATION (FILTERING)

In this model, the air passes through the charcoal ilters to be puriied 
and recycled in the environment.

Ensure that the active carbon ilters are assembled into the hood, if not, 
install them as indicated in the assembly instructions. 

In this version the check valve must not be assembled: remove it if it is on the air 
outlet itting of the motor.

ASSEMBLY INSTRUCTIONS

only intended for qualiied personnel

The hood can be installed in various conigurations.

The generic assembly steps apply to all installations; for each case, follow 
the speciic steps provided for the required installation.

OPERATION

WHEN TO TURN ON THE HOOD?

Switch on the hood at least one minute before starting to cook to direct fumes and vapours 
towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours. 
By means of the Timer function, it is possible to set auto switch-of function which will allow 
the hood to turn of automatically after 15 minutes of operation.

WHICH SPEED IS TO BE SELECTED?

1st speed:

 maintains the circulation of clean air with low electricity consumption.

2nd speed:

 normal conditions of use.

3rd speed:

 presence of strong odours and vapours.

4th speed:

 rapid disposal of odours and vapours.

WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?

The metal ilters must be cleaned every 30 hours of operation. 
The active carbon ilters must be replaced every 3-4 months, depending on the use of the 
hood.
For further details see the 

“MAINTENANCE” 

chap.

ELECTRONIC PUSHBUTTON PANEL 

(LAGUNA PANNELLABILE)

Motor ON/OFF

Upon start-up, the speed is that stored at the previous operation.

Increase speed from 1 to 4

Speed 4 is only active for a few min-
utes

The speeds are indicated by the LEDs 
on the keys:

 

Speed 1

 Speed 2

 Speed 3

 Speed 4 

("+" LED lashing)

Reduce speed from 4 to 1

 

Light on/of

TIMER

 (

red LED lashing)

Auto switch-of after 15 min.
The function deactivates (red LED of ) if:
- The TIMER key (

) is pressed again.

- The ON/OFF key (

) is pressed.

FILTER ALARM

 

(red LED steady on)

Anti-grease ilter maintenance after approximately 30 hours of operation.
Press the meter for 3 seconds to reset.

Summary of Contents for Laguna pannellabile

Page 1: ...LIBRETTO ISTRUZIONI UK INSTRUCTIONS BOOKLET DE GEBRAUCHSANWEISUNG FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES RU PL INSTRUKCJA OBS UGI NL HANDLEIDING PT MANUAL DE INSTRU ES DK BRUGSANIVSNINGER SE INST...

Page 2: ...2 8 mm 6 mm LAGUNA 60 34 kg LAGUNA 90 45 kg LAGUNA PANNELLABILE 60 21 kg LAGUNA PANNELLABILE 90 28 kg LAGUNA 60 90 598 898 419 165 R150 870...

Page 3: ...A LAMBRISS E 60 90 dimensions panneaux ES LAGUNA PANELABLE 60 90 medidas de los paneles RU LAGUNA 60 90 PL LAGUNA PANELOWA 60 90 wymiary paneli NL LAGUNA BEKLEEDBAAR MET PANELEN 60 90 afmeting panelen...

Page 4: ...tallazione UK Measurements for installation DE Ma angaben f r die Installation FR Mesures pour l installation ES Medidas para la instalaci n RU PL rodki monta owe NL Maten voor de installatie PT Medid...

Page 5: ...iltros met licos 2 Fixa o do exaustor 3 DK Fjern panelet 1 jern metaliltrene 2 Fastg relse af emh tten 3 SE Ta bort panelen 1 och avl gsna metalliltren 2 F stning av k pan 3 FI Irrota paneeli 1 ota po...

Page 6: ...montaje del tubo de aspiraci n 5 Montaje de los paneles de serie 6 RU 4 5 6 PL Monta zaworu zwrotnego 4 monta rury ss cej 5 monta paneli seryjnych 6 NL Montage terugslagklep 4 en zuigleiding 5 Montag...

Page 7: ...on lambriss e ES Montaje de los paneles de la versi n panelable RU PL Monta paneli wersji panelowej NL Montage panelen voor met pa nelen bekleedbare versie PT Montagem pain is vers o com pain is DK Mo...

Page 8: ...tros met licos 11 volver a poner el panel 12 RU 10 11 12 PL Po czenia elektryczne 10 za o y iltry metalowe 11 za o y panel 12 NL Elektrische aansluitingen 10 metalen ilters 11 her monteren paneel 12 h...

Page 9: ...5 RU 13 14 15 PL Zdj panel 13 zdj metalowe iltry 14 zamontowa iltry z w glem aktywnym 15 NL Verwijder paneel 13 verwijder de metalen ilters 14 monteer de actieve koolstoilters 15 PT Remover o painel 1...

Page 10: ...i sia conservato insieme all apparec chiatura per qualsiasi futura consultazione Se l apparecchio dovesse essere venduto o trasferito ad un altra persona assicurarsi che an che il libretto venga forni...

Page 11: ...ibrazioni e di ridurre la capacit aspiran te della cappa E necessario isolare la tubazione se passa attraverso ambienti freddi Per impedire ritorni d aria dall esterno una valvola di non ritorno prese...

Page 12: ...Per la sostituzione dei iltri al carbone attivo vedi istruzioni di montaggio ILLUMINAZIONE La cappa dotata di illuminazione tramite faretti led ad alta eicienza basso consumo e durata molto elevata i...

Page 13: ...rovata da ricevuta iscale o altro documento reso iscalmente obbligatorio La garanzia sar prestata con la sostituzione o riparazione gratuita delle parti che risultino difettose per vizi delle stesse i...

Page 14: ...he safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the equipment is sold or transferred to...

Page 15: ...quired to insulate the pipes if it passes through cold environments In the presence of motors with 800m3 h or higher a check valve is present to prevent external air lowing back Deviation for Germany...

Page 16: ...ial to darken to reduce the possibility of this problem from happening use low temperature washes 55 C max To extract and insert the metal anti grease ilters see the assembly instructions ACTIVE CARBO...

Page 17: ...austieren ab die durch eine Nichtbeachtung der in der vorliegen den Gebrauchsanweisung angef hrten Sicherheitshinweise verursacht werden Es ist sehr wichtig dass diese Gebrauchsanweisung zusammen mit...

Page 18: ...ntil Abweichungen f r Deutschland Wenn die Herdabzugshaube gleichzeitig mit Ger ten betrieben wird die mit einer anderen Energie als elek trischem Strom betrieben werden darf der negative Druck im Rau...

Page 19: ...der Sp lmaschine gereinigt werden aber es k nnte zu einer Braunf r bung des Materials kommen Um dies zu vermeiden einen Sp lgang mit niedriger Temperatur max 55 C w hlen F r die Montage und Demontage...

Page 20: ...on future Si l appareil devait tre vendu ou transf r une autre personne s assurer que le manuel soit remis avec celui ci de mani re ce que le nouvel utilisateur puisse conna tre le fonctionne ment de...

Page 21: ...la tuyauterie si elle passe par des endroits non chauf s Pour emp cher les retours d air de l ext rieur un clapet de non retour est install en pr sence des moteurs avec 800 m3 h ou sup rieurs D viati...

Page 22: ...avage en lave vaisselle est permis mais il pourrait ternir le mat riau des iltres pour r duire cet inconv nient utiliser des lavages basses temp ratures 55 C max Pour l extraction et l introduction de...

Page 23: ...indicadas en este manual Es muy importante que conserve este libro de instrucciones del equipo para consul tas futuras Si el equipo debe venderse o cederse a otra persona compruebe que se adjunte el...

Page 24: ...la tuber a si pasa a trav s de ambientes fr os Para impedir retornos de aire desde el exterior hay una v lvula de no retorno en presen cia de motores con 800 m3 h o superiores Desviaci n para Alemania...

Page 25: ...er el ma terial de los iltros para reducir este inconveniente utilice bajas temperaturas 55 C m x Para extraer y montar los iltros met licos consulte las instrucciones de montaje FILTROS DE CARB N ACT...

Page 26: ...26 2 13 8 1 5 65 25 6 EN60335 2 31 11 07 2002 TC61 7 12 1 15 10 11...

Page 27: ...27 70 C III 800 3 4 4 x 10 5 15 I II III IV 30 3 4 LAGUNA PANNELLABILE 1 4 4 1 2 3 4 4 1 15 30 3...

Page 28: ...28 1 3 24 1 3 1 24h 2 3 4 3 15 30 3 15 Magic Steel 1 55 C 3 4 12V 3 1 2 RAEE RAEE...

Page 29: ...ej instrukcji obs ugi razem z urz dzeniem jest bardzo wa ne w celach wszelkiej przysz ej lektury Gdyby urz dzenie zosta o sprzedane lub przeniesiona zosta a jego w asno na strony trzecie nale y upewni...

Page 30: ...ietrza z zewn trz w przypadku silnik w o wydajno ci 800m3 h lub wi kszej wyst puje zaw r zwrotny Odst pstwo dla Niemiec gdyokapkuchennyiurz dzeniazasilaneenergi nieelektryczn funkcjonuj jednocze nie u...

Page 31: ...Mycie w zmywarce do naczy jest dozwolone lecz mo e doprowadzi do po wstania zaczernie na materiale z kt rego wykonane s iltry Aby ogra niczy wyst powanie tego zjawiska korzysta z program w o niskich...

Page 32: ...worden veroorzaakt aan personen voorwerpen en huisdieren ten gevolge van het niet naleven van de veiligheidsaanwijzingen in deze handleiding Het is zeer belangrijk dat deze handleiding samen bij het...

Page 33: ...dient deze ge soleerd te worden Bij motoren van 800m3 h of meer is een terugslagklep aanwezig om terugstroming van de buiten lucht te vermijden Aanvulling voor Duitsland Wanneer de afzuigkap gebruikt...

Page 34: ...tage instructies voor het plaatsen en verwijderen van de metalen vet ilters ACTIEVE KOOLSTOFFILTERS Deze ilters absorberen de geuren aanwezig in de lucht die erdoor gaat De gezuiverde lucht wordt weer...

Page 35: ...este manual de instru es seja conservado com o equipa mento para consultas futuras Se o aparelho tiver que ser vendido ou transferido para uma outra pessoa certiicar se de que o manual seja fornecido...

Page 36: ...a impedir retornos de ar do exterior deve estar presente uma v lvula de n o retorno em caso de motores com 800m3 h ou superiores Desvio para a Alemanha quando o exaustor de cozinha e os aparelhos alim...

Page 37: ...os nova mente permitido lavar na m quina de lavar mas pode ocorrer o a forma o de manchas escuras no material dos iltros para reduzir este inconveniente utilizar lavagens com baixas tempe raturas 55 C...

Page 38: ...lge af manglende overholdelse af sik kerhedsinstruktionerne i dette h fte Det er meget vigtigt at denne brugsanvisning opbevares sammen med apparatet til fremtidig brug S rg for at brugsanvisningen f...

Page 39: ...iteten Det er n dvendigt at isolere r rf ringen hvis den passerer kolde rum For at forhindre luft udefra i at tr nge ind er der placeret en kontraventil n r der er instal leret motorer med en kapacite...

Page 40: ...le For at reducere denne farvning anbefales det at anvende vaskeprogram mer med lave temperaturer Maks 55 C For udtagning og bis ttelse af fedtiltrene i metal se monteringsvejledningen AKTIVE KULFILTR...

Page 41: ...rem l och husdjur till f ljd av underl tenhet att f lja de s kerhetsanvisningar som anges i denna manual Det r mycket viktigt att denna instruktionsbok f rvaras tillsammans med apparaten f r framtida...

Page 42: ...F r att f rhindra ett terl de av luft utifr n sitter en backventil installerad p motorer med 800m3 h eller mer Avvikelse f r Tyskland N r k ksl kten och apparater som matas med annan energi n elektric...

Page 43: ...l ten men kan orsaka brunf rgning av iltren f r att minska detta problem skall du tv tta vid l ga temperaturer max 55 C Se monteringsanvisningarna f r uttag och ins ttning av metallfettiltren AKTIVA K...

Page 44: ...misest On eritt in t rke ett t m ohjekirja s ilytet n yhdess laitteen kanssa tulevaa k ytt varten Jos laitteisto myyd n tai annetaan toiselle henkil lle varmista ett my s ohjekirja toimite taan sen m...

Page 45: ...t miseksi Putket on eristett v jos ne kulkevat kylmien tilojen l pi Ulkoilman palautumisen est miseksi tuulettimessa on vastaventtiili Saksan poikkeus kun liesituuletinta ja muulla kuin s hk ll toimiv...

Page 46: ...m ksisi pesuaineita Huuhtele ne huolellisesti ja odota niiden t ydellist kuivumista ennen takaisin asennusta Pesu pesukoneessa on sallittua mutta voi aiheuttaa tummentumia suodattimien materiaa lille...

Page 47: ...overholdelse av sik kerhetsanvisningene i denne bruksanvisningen Det er meget viktig at denne bruksanvisningen oppbevares sammen med apparatet for fremtidig bruk P se at bruksanvisningen f lger med ap...

Page 48: ...er n dvendig isolere r rene som passerer gjennom kalde milj er For unng retur av luft fra utsiden innes en tilbakeslagsventil ved bruk av motorer med 800m3 h eller mer Avvik for Tyskland n rkj kkenhe...

Page 49: ...n medf re misfarging av iltermaterialet dette problemet reduseres ved bruke vaskeprogrammer med lave temperaturer 55 C maks For uttrekking og innsetting av fettmetalliltrene se montasjeanvisningene FI...

Page 50: ...50 NOTE NOTES...

Page 51: ...51 NOTE NOTES...

Page 52: ...FALMEC S p A 31029 VITTORIO VENETO Treviso ITALY Zona Industriale Via dell Artigianato 42 www falmec com Code 110031048 Ed 01 2016 Codice Code Matricola Serial Number...

Reviews: