2

1081

1098

510

715

 738 

 1026 

 max 400 

 220 

92

84

 341 

 103 

 275 

 109 

 90 

 1081 

 220

 90

 308 

109

103

879

46 kg

Downdraft 120

37 kg

109

341

92

798

726

824

738

1,5

336

275

104

715

max 400

781

 781 

220 

90

 92 

 82 

 237 

390,5 

Downdraft 90

84

Summary of Contents for Downdraft 120

Page 1: ...INSTALLATION MANUAL falmecau com Downdraft...

Page 2: ...510 715 738 1026 max 400 220 92 84 341 103 275 109 90 1081 220 90 308 109 103 879 46 kg Downdraft 120 37 kg 109 341 92 798 726 824 738 1 5 336 275 104 715 max 400 781 781 220 90 92 82 237 390 5 Downd...

Page 3: ...3 Downdraft 90 120 Downdraft 90 120 349 246 97 92 191 540mm quota minima con curva 90 Falmec 321 361 471 540mm using 90 bend Falmec 781 715 max 400 738 474 241 92 1 5 84 109 Remote motor...

Page 4: ...4 396 510 510 737 879 Rear view side front hood 70 24 B 1 4 2 4 57 32 6 D 1 3 8 mm 6 mm Downdraft 90 120 Downdraft 90 120 Motor PIN INSTALLATION WITH BACK MOTOR...

Page 5: ...5 810 mm 1110 mm 98 mm 60 mm 715 mm motor pin 738 mm max 1 2 7 0 m m 5 7 m m 2 1 Ideal size PRELIMINARY OPERATIONS Recess hole dimensions 1 fixing to the support surface 2...

Page 6: ...6 230V 3seconds 230V 3 4 5 PRELIMINARY OPERATIONS PRELIMINARY OPERATIONS Temporary electrical connection 3 Opening the hood for installation 4 5...

Page 7: ...7 Configuration with front motor Remove the cover 6 remove the metal side panels 7 fix motor KACL784 8 1 7 8 6 KACL 784...

Page 8: ...8 Configuration with back motor Remove the cover 9 remove the metal side panels 10 fix motor KACL784 11 1 10 11 9 KACL 784...

Page 9: ...9 Installing the carbon zeolite filter optional 12 Front motor 13 back motor 14 AIR AIR AIR AIR KACL 930 TYPE B TYPE A MAGNET TYPE A TYPE A 12 13 14 CARBON ZEO LITE FILTER INSTALLATION...

Page 10: ...CL 798 15 Replace the original inlet 15 with the bracket fixing the motor to the hood 16 secure the motor to the hood if the air exhaust is on the front 17 For other directions see 18 19 6 OUTLET 16 1...

Page 11: ...11 360 AIR 19 x 8 4 2 1 180 3 90 5 x 8 6 OUTLET Side movement of the air exhaust 18 KACL 798...

Page 12: ...12 360 AIR 6 OUTLET Configuration with back motor 1 21 22 20 KACL 798...

Page 13: ...13 Rectangular pipes 23 round pipes 24 90 220 Motor Motor 23 24 ONLY FALMEC MOTORS ONLY FALMEC MOTORS CONFIGURATION WITH REMOTE MOTOR...

Page 14: ...14 25 Onboard motor 25 Remote motor 26 26 ELECTRICAL CONNECTION...

Page 15: ...15 Magnets Brackets fixing to the TOP 27 Fixing the control unit to the hood 28 Hand anti crushing warning 29 29 28 27...

Page 16: ...using the or cleaning the equipment The Manufacturer declines all responsibility for any damage caused directly or in directly to persons things and pets as a consequence of failing to comply with the...

Page 17: ...sence of motors with 800m3 h or higher a check valve is present to prevent external air lowing back Deviation for Germany when the kitchen hood is used at the same time as appliances that are powered...

Page 18: ...created by following the procedure below Disconnect the power to the hood before starting the procedure 1 CREATE A NEW CODE The procedure is to be carried out on the radio control Press LIGHT and TIM...

Page 19: ...cedure Remove the ilter as described in the instructions Place the 4 ilters 3 x type A and 1 x type B in a domestic oven at 200 C for about 2 hours When the ilter has cooled down reit the 4 ilters ont...

Page 20: ...ct by building materials of any kind will be required to be removed and reinstalled by the customer 10 PR Kitchens Washrooms has a service network in all metropolitan areas and most regional areas Whe...

Page 21: ...21 NOTE NOTES...

Page 22: ...22 NOTE NOTES...

Page 23: ...23 NOTE NOTES...

Page 24: ...o Treviso Italy falmec com Australia PR Kitchen Washroom Systems 83 Bangholme Rd Dandenong South VIC 3175 Australia 61 3 9700 9100 info prks com au New Zealand PR Kitchen Washroom Systems NZ P O Box 5...

Reviews: