background image

 

 

 

Fallprotec S.A. 43-45. ZA Op Zaemer. L-4959 Bascharage. Luxembourg 
T +352 26 55 09 30  F +352 26 55 09 30 55   
[email protected]

 

 

 
User Manual 

Securope 2012 
Horizontal 

 

DOC039-UK-19.07.15 

 

 

 

Summary of Contents for Securope 2012

Page 1: ...Fallprotec S A 43 45 ZA Op Zaemer L 4959 Bascharage Luxembourg T 352 26 55 09 30 F 352 26 55 09 30 55 marketing fallprotec com User Manual Securope 2012 Horizontal DOC039 UK 19 07 15 ...

Page 2: ...de for curve 8 2 Marking 9 2 1 Warning plate 9 2 2 End anchor 10 2 3 Intermediate anchor NEO 11 2 4 Glider 11 2 5 Captive glider 12 2 6 Energy absorber 12 3 Homologation 13 4 Instruction for resale 13 5 Skills of the installer 13 6 Installation of Securope 13 6 1 Structure on which the Securope is installed 15 7 Personal protective equipment 16 8 Recommendations relating to the documentation requi...

Page 3: ...pe 2012 horizontal DOC039 UK 19 07 15 3 9 1 6 Prohibited use 22 9 1 7 Instructions for storage and maintenance 22 9 1 8 Operational life of the installation 23 10 Recommandations relating of periodic review procedure 24 ...

Page 4: ...cable by means of a mobile anchor point further referred to the glider The SecuRope lifeline enables the user to move freely to any point on the lifeline where there is a risk of falling without the need to detach themselves from the cable at any time The user wears a harness according to EN 361 fitted with a lanyard and a connector according to EN 362 and is attached to the life line using a glid...

Page 5: ...uction 7x7 material AISI 316 Fig 1 LDV006 wire rope 1 3 2 Terminale anchors Terminal anchors are installed at the ends of the line material AISI 316 Fig 2 LDV002 terminal anchor 1 3 3 Intermediate anchor NEO Intermediate anchors are arranged along the lifeline at intervals between 2 and 12 m Material AISI 316 Fig 3 LDV043 Intermediate anchor NEO ...

Page 6: ...431 Fig 4 LDV001 Glider 1 3 5 Captive glider The captive glider is permanently attached to the line Material AISI 316 Fig 5 LDV060 Captive glider 1 3 6 Energy absorber The energy absorber reduces the force which is transmitted to the building structure in case of a fall An energy absorber is mandatory when the line is less than 20 m Material polyurethane 95 shore Fig 6 LDV032 Energy absorber ...

Page 7: ...mping ring 100mm 1 3 8 Line tensioner The tensioner serves as a stop for the line and allows the tensioning of the line Fig 8 The tensioner serves as a stop for the line and allows the tensioning of the line 1 3 9 Crimping ring for junction The crimping ring for junction allows end to end attachment of the wire rope Fig 9 Crimping ring for junction ...

Page 8: ...s end to end attachment of the wire rope in case of a closed loop Fig 10 LDV138 Turnbuckle 1 3 11 Cable guide for curve The cable guide for curve is used in conjunction with the corner plate and allows the tensioning of the cable from one of the ends of the line Fig 11 LDV076 Cable guide for curve ...

Page 9: ...ufacturer informations and a QR code to get direct access to all the informations related to the installation Equipment type and applied standards Logo and installer name Symbol indicating that it is mandatory to use a fallarrest harness according to EN355 Maximal number of users and their weights Information about the installation place Commissioning date It is mandatory to read the user manual b...

Page 10: ...or Engraving shows The name of the manufacturer Fallprotec The name of the componant Terminal Anchor The standard N EN795 Type C 2012 The logo directing to read the user manual The batch number QQ AA quarter year Internet adress www fallprotec com Fig 12 End anchor marking ...

Page 11: ...tandard N EN795 Type C 2012 The logo directing to read the user manual The batch number QQ AA quarter year Internet adress www fallprotec com Fig 13 LDV034 Intermediate anchor NEO marking 2 4 Glider Engraving shows The name of the manufacturer Fallprotec The batch number month year The standard N EN795 Type C 2012 The CE mark The logo directing to read the user manual Fig 14 Glider marking ...

Page 12: ...the manufacturer Fallprotec The batch number month year The standard N EN795 Type C 2012 The CE mark The logo directing to read the user manual Fig 15 Captive glider marking 2 6 Energy absorber Engraving shows The name of the manufacturer Fallprotec The batch number month year Fig 16 Energy absorber marking ...

Page 13: ...ns for maintenance for periodic reviews and instructions on repairs in the language of the country of use 5 Skills of the installer The anchor device must be installed by competent persons or organizations that will have a certificate of approved installer issued by Fallprotec The installation must be properly verified by calculation or testing The installation will be carried out in conformity wi...

Page 14: ...ulated and required in case of a fall Fall clearanceAvailable actual height available between the path and the first obstacle LPath distance from the rigid anchor line to the edge LLanyard lenght of the lanyard 2m LAbsorber deployment of the energy absorption system 0 8m HUser user s height Fall clearance Available Fall clearanceRequired DDeflection LLanyard LAbsorber LPath HUser HSafety Fall clea...

Page 15: ...he end and intermediate anchors when a fall is stopped Fallprotec makes software available approved by the notify body which works out the forces in accordance with the site configuration and the number of users The components of the Securope line withstand without permanent deformation the forces indicated to table below and present a safety coefficient of two The forces calculated by the softwar...

Page 16: ... 7 Personal protective equipment The Securope lifeline should be used in conjunction with height safety PPE in accordance with EN354 EN355 EN361 EN362 Fig 18 HAR010 Longe simple avec absorbeur Fig 19 HAR018 HAR013 Connecteur tour Fig 20 HAR001 Harnais Prolight ...

Page 17: ... plan of the installation for example the roof and information relevant to the user such as the position of the anchor points for example relevant in case of snow Should be marked on the schematic plan of the building so that it is visible or available to all for example at the point of access to the roof The statements made by the responsible installer must be signed by him and attest that at lea...

Page 18: ...Test device Hammer Rotative Wrench Cleaning of the drilled hole Testing devise of fixations System impact yes Humid yes No dry No Control list Ground plan of the roof Substrate except exceptions no doubt on the capacity Installation in accordance with manufacturer s instructions Recommended attachments used All attachements photographed with identification Visibles attachments Installation plan at...

Page 19: ...r anchoring the harness the dorsal anchoring point being used for rescue operations o An energy absorber lanyard in conformity with EN 354 355 standard o Two karabiners twist lock type in zinc plated steel according to EN 362 and having the following characteristics length 105 mm width 58 mm wire diameter 10 mm opening 20 mm breaking strength 23 kn o On arrival in the work area or whenever the use...

Page 20: ...of the two end anchors The user must use a mobile anchor point hereinafter referred to glider and the associated connector 9 1 2 Use of the glider LDV001 The glider is attached to the cable side to the user see Fig 38 Fig 23 Correct orientation of the glider To connect the glider the user tilts the glider opens the locking device and fits the glider over the cable see Fig 7 8 9 Fig 24 Locking devi...

Page 21: ...henever he needs to move from one side of the cable to the other 9 1 3 Circulating along the lifeline The user pulls on the glider via the lanyard to allow the glider to pass the intermediate anchors without jolting Fig 27 Glider attached to the cable 9 1 4 Use of a fall arrest block attached to the line The Securope Lifeline may be used in conjunction with a fall arrest block IHW range distribute...

Page 22: ...tructions for storage and maintenance The glider must be stored in a place away from moisture The SecuRope lifeline must be inspected by a qualified person at least once a year as well as after every fall The safety of the users depends on the maintenance of the effectiveness and the resistance of the equipment Reconditioning of the line after a fall requires a re tensioning of the cable using FAL...

Page 23: ...e manufactured from of stainless steel according to the AISI 316 431 304 which have a great resistance to the atmospheric degradation The operational life is a function of the building structure and of its capacity to maintain its physical properties in the course of time The operational life of the Securope lifeline is limited to 20 years ...

Page 24: ...lation Marking and documentation relating to the review Manufacturer identified visible Fixation No visible Fixation Review in accordance with the construction technical regulations of manufacturer regarding the type of load type of fixing and mounting structure Review in accordance with the information supplied by manufacturer of type of test for example visual review and functional test static t...

Page 25: ...rs Date of 1st review Type of review repairs Name and signature of competent person Date of the next review After 1 year of use Visual Cleaning of the Securope lifeline Verification of energy absorbers Verification of intermediate anchors cable guide in the correct position Periodicity once a year Check that the turnbuckle LDV038 is not released tighten and lock it with Loctite The correct tighten...