background image

Summary of Contents for GSM

Page 1: ......

Page 2: ...V1 0 08 Jul 2021...

Page 3: ...3 1 1 Power Supply 8 3 1 2 Check AC 8 3 1 3 Dry Contact Inputs 8 3 1 4 Contact ID Inputs 9 3 1 5 Serial Port 9 3 2 Falcon GSM Installation 10 3 3 GSM Connection and Signal Strength 10 3 5 Selecting t...

Page 4: ...APPENDIX A Serial Interface 19 4 2 PC based Programmer 18 APPENDIX B Programming Cable Software 25 4 PROGRAMMING 18 4 1 Onboard Push Button 18...

Page 5: ...s the universal Contact ID interface to alarm panels as well as a serial interface to leading panels It also has seven dry contact input triggers In addition the Falcon GSM has two dry contact relay o...

Page 6: ...tip and ring telephone interface to leading control panels Serial alarm interface to leading control panels Over the air panel uploading and downloading on the Rhino and Texecom Premier control panels...

Page 7: ...3 INSTALLATION 3 1 Falcon GSM Wiring Connections to the Falcon GSM are shown below SERIAL CAC 12V GND 1 2 3 4 5 6 7 C1 C2 NO1 TIP RING T R NO2 GSM Falcon GSM Installation and Operation Manual I 7 GSM...

Page 8: ...ains The CAC input will detect AC voltages between 10 and 24V If the CAC line is not connected the Falcon GSM should not be programmed to send AC Fail or AC Restore signals The AC Fail and AC Restore...

Page 9: ...programmed to use its dialer and the option for reporting must be set to Contact ID Refer to the programming manual of the applicable alarm panel 3 1 5 Serial Port The Falcon GSM can receive alarms fr...

Page 10: ...SM network The Falcon GSM will send alarms quicker and more reliably if it has a strong connection to the GSM service provider For the software version 4 20 and hardware version A 3 1 6 Relay Outputs...

Page 11: ...sim When the Falcon GSM has powered up it will start connecting to the network displaying its status as it initialises and connects see section 3 5 Indicators and Controls 3 4 Changing the Default SI...

Page 12: ...nal strength required is 5 Lower than this signal strength will make it dif cult to access the Falcon GSM remotely 3 5 Selecting the Alarm Panel Serial Port Format The alarm panel serial port can be s...

Page 13: ...down the push button and re apply the power Release the button then push the button to cycle through the panel serial port settings until the correct serial port is displayed Leave the button for 15 s...

Page 14: ...C Neo Series S Sherlotronics DISPLAY SERIAL FORMAT Pima Hunter Pro F Texecom Premier t P Rhino Paradox r i IDS b DSC Power Series E IDS805 FSK Key bus GSM I Falcon GSM Installation and Operation Manua...

Page 15: ...GSM Falcon GSM Installation and Operation Manual I 15 DISPLAY SERIAL FORMAT Risco LightSYS 2 A DESCRIPTION CHARACTER FLASHED STATUS The communicator is starting the GSM modem Initialising i Restartin...

Page 16: ...SM detects an error it will ash the error code on the seven segment display DESCRIPTION CHARACTER FLASHED STATUS E1 SIM card not found The communicator has not detected a SIM card which it has been pr...

Page 17: ...cator cannot connect to the server to route the GPRS message to the control room Make sure that the programming of the Server GPRS settings are correct The GSM network may be experiencing technical pr...

Page 18: ...n GSM The Falcon GSM programmer requires a PC running Windows XP or above with an available USB Port The FSK USB programming cable is required to program the Falcon GSM see Appendix B To program the u...

Page 19: ...terchangeable The following adapter boards are available VERY IMPORTANT Plug the adapter board into the alarm panel and NOT the Falcon GSM GSM Falcon GSM Installation and Operation Manual I 19 ALARM P...

Page 20: ...tallation and Operation Manual 20 Set the serial port format to Texecom on the Falcon GSM Refer to Section 3 4 Connect the Falcon GSM to Com1 on the alarm panel using the serial interface cable with t...

Page 21: ...s which will be needed to connect to the alarm panel via the Falcon GSM Please refer to the FSK APN USER GUIDE PARADOX SERIAL INTERFACE The Falcon GSM can send alarms received from the serial port of...

Page 22: ...el Plug the other end into the Falcon GSM s serial port Proceed to program the panel as per the Falcon Connection App Set up Guide provided for alarm signals to be sent and or for app connectivity DSC...

Page 23: ...connector to the serial port of the Falcon GSM IDS X SERIES SERIAL INTERFACE Set the serial port format to IDS on the Falcon GSM Refer to Section 3 4 Proceed to program the panel as per the Falcon Con...

Page 24: ...lcon GSM can send alarms received from the COM 1 serial port of the Orisec alarm panel with a rmware version of 4 52 or later Plug the side of the serial cable labelled panel side into the serial port...

Page 25: ...Programming Cable and FSK DVD kit which contains the programming software FSK Item Code 40027 Installing the drivers for the FSK USB to UART Programmer Install the drivers before plugging the USB Prog...

Page 26: ...USB Serial Adapter Drivers For 64 bit operating systems double click on CP210xVCPInstaller_x64 exe Otherwise double click on CP210xVCPInstaller_x86 exe Follow the instructions on DRIVER software to in...

Page 27: ...le click on the setup exe application and follow the instructions Upon opening the software for the rst time it will require an initial setup The following window will pop up Select the folder where t...

Page 28: ...hat will be used to communicate with the device From there the following window will appear Connect the Falcon GSM to the correct COM port and click on the read button GSM I Falcon GSM Installation an...

Page 29: ...Upon completion the window will look like this All the settings that are greyed out cannot be changed GSM Falcon GSM Installation and Operation Manual I 29...

Page 30: ...All the input and output settings can be changed by clicking on the Input Output Settings Tab GSM I Falcon GSM Installation and Operation Manual 30...

Page 31: ...the face hereof In no case shall seller be liable to anyone for any consequential or incidental damages for breach of this or any other warranty express or implied or upon any other basis of liabilit...

Page 32: ...Amecor House 14 Richard Road Industria North 1709 support fsk co za 27 11 477 7705 technical support...

Reviews: