the drain line.
A.Hang the bowl on the bracket
and check tail pipe alignment,
then remove the bowl and adjust the bracket as needed.
Re-hang and re-check bowl
alignment with
Tail pipe should align with center of drain line.
B. Mark anchor holes
then remove
bowl without moving hanger bracket.
A.Find the drain nipple depth
on the Tube
B.
Cut the tube
at the groove using a sharp
utility knife to ensure a square, flat cut.
C.
Clean burrs
from the cut end by using
emery paper.
D.
Apply lubricant
to the outside of the rubber bushing and
ribbed inside area.
E.
Insert the tube
and bushing with arrow tab at the top.
Apply lubricant to tailpipe of housing.
USE UTILITY KNIFE TO CUT CAULK
then
use a putty knife and mallet to remove the
bowl. Remove hanger brackets, scrape off
caulk, and clean the wall.
.
DETERMINE THE DRAIN NIPPLE DEPTH
by measuring the distance between the back
of the sanitary tee (or elbow) to the front
edge of the nipple.
IMPORTANT:
Use a drain machine to remove
build-up inside pipes. Clean up to 25 feet deep
then flush with water to remove cutting debris.
Never install on copper DWV.
A. Clean face
of existing wall flange.
B. Install the brass flange
with the clear inspection disc.
C. Slowly pour water
into the drain.
D. Use a flashlight to check the pitch/slope
No water
should be present in the inspection disc or nipple.
E. Remove flange
after inspection.
ADJUST DRAIN TO ACHIEVE PITCH
only if
standing water is present (code requires ¼"drop
per foot of drain line for proper pitch). Seal wall
according to code.
PLACE THE SEAL INTO THE
FLANGE
with the ribs facing
out. Install the flange with
washers and hex nuts, but
do not tighten completely.
HANG THE BOWL,
inserting
tailpipe into bushing, then
install anchor screws with
washers.
TIGHTEN FLANGE
BOLTS AND GEAR CLAMP.
POUR 5
GALLONS
OF WATER
as rapidly as
possible into housing
to ensure good flow and no
leaks or standing water.
INSTALL THE GEAR
CLAMP
with screw
head at bottom, but
do not tighten.
DRILL HOLES
with 5/16”
masonry bit for the lower
anchor screws and insert
plastic anchors.
The information in this document is
subject to change without notice.
©2015 Falcon Waterfree Technologies,
LLC. All rights reserved.
FalconWaterfree.com
CAULK THE BOWL TO THE
WALL
if there is good flow
and no leaks or standing
water.
CARTRIDGE
INSTALL
per the cartridge instruction
sheet.
•
Check rough-in height to achieve 24"
rim height (17" rim height for ADA).
•
Check slope. Downhill slope, per code,
is essential because waterfree urinals
require gravity flow for drainage.
•
Check DWV material. Suitable materials
include cast iron, PVC, ABS, and
galvanized steel.
•
Never install on copper DWV due to
copper’s susceptibility to corrosion
.
•
Shut off water supply and cap the nipple
with the ¾" chrome cap (provided).
•
Measure drain nipple depth (in inches)
to find trim length (in inches)
•
13
7 8
" or more
DO NOT CUT TUBE
•
3 ¾" or less
DO NOT USE TUBE
BEFORE STARTING INSTALLATION
TUBE CUTTING CHART
F1000
RETRO-FIT INSTALLATION
WATERFREE URINAL
CUSTOMER CARE
2" side cutter blade
Cut away wall
Lift drain line & brace
with mending plate
Install additional
screws here
INCORRECT
Not centered
CORRECT
Centered
11
10
12
CARTRIDGE
INSTRUCTIONS
CAUTION
After removing any urinal from the
drain line, it’s normal for certain naturally occurring
but
potentially hazardous sewer gases
to escape
through the opening until the waterless cartridge
is installed properly into the waterless urinal. If you
need to leave an open drain line unattended after
removing the urinal from the wall, temporarily wedge paper towels or a
rag into the drain hole to reduce any outflow of sewer gases, and remove
the paper towels or rag prior to completing the urinal or cartridge
installation.
Never smoke, have an open flame, or place your nose or
mouth near open drain lines or waterless urinal housings into which
a cartridge is not yet properly installed.
You also can wear a breathing
mask when removing or installing any waterless urinal or cartridge to
reduce potential exposure to any such gases.
OR LESS
TRIM
13 ¾"
¾
"
13 ½
½
13 ¼
¼
13
1
12 ¾
1¾
12 ½
1½
12 ¼
1¼
12
2
11 ¾
2¾
11 ½
2½
11 ¼
2¼
11
3
10 ¾
3 ¾
10 ½
3 ½
OR LESS
TRIM
10 ¼"
3 ¼
"
10
4
9 ¾
4 ¾
9 ½
4 ½
9 ¼
4 ¼
9
5
8 ¾"
5 ¾
8 ½
5 ½
8 ¼
5 ¼
8
6
7 ¾
6 ¾
7 ½
6 ½
7 ¼
6 ¼
7
7
OR LESS
TRIM
6 ¾"
7 ¾
"
6 ½
7 ½
6 ¼
7 ¼
6
8
5 ¾
8 ¾
5 ½
8 ½
5 ¼
8 ¼
5
9
4 ¾
9 ¾
4 ½
9 ½
4 ¼
9 ¼
4
10
21½
Install plastic anchor
and screw here
15
16
4
14
7
3
13
9
6
2
11
12
10
8
5
1
1
2
3
4
Arrow
tab UP
1
2
3
4
A
C
B
D
E
B
C
D
A
B
existing bearing rods
LEVEL THE BRACKET THEN MARK,
drill and install
two additional plastic anchors and screws. If pre-
can be used, screws are
not necessary.
MEASURE & MARK THE ROUGH-IN
is in-wall
drill hole, then install the hanger bracket with
one plastic anchor and screw.
carrier is not used. Use a 5/16” masonry bit to
Cutting Chart (left).
Measure and mark the
specified trim length
on the insert tube at
the nearest 1/4” groove.