INSTALLATION
Check the appliance is electrically safe when you have finished.
ArtNo.130-0010 Electrical connections single-phase
L
N
230 V ac 50 Hz
10 mm² max
6 mm² max
L1
N
L3
L2
3N ac
230/400 V 50 Hz
6 mm² max
10 mm² max
6 mm² max
The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
n
n
WARNING: THE APPLIANCE MUST BE EARTHED.
Note:
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
n
n
The cooker MUST NOT be connected to an ordinary
domestic power point.
The total electrical load of the appliance is approximately
3.6 kW. The cable size used should be suitable for this load
and comply with all local requirements.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (Fig. 9.1 and Fig. 9.2). Check that the links are correctly
fitted and that the terminal screws are tight. Secure the mains
cable using the cable clamp.
These appliances are of type X with regard to protection
against overheating of the surrounding surfaces.
Fig. 9.1
Fig. 9.2
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we recommend
that the cooker is protected on an individual RCD (Residual
Current Device) or RCBO (Residual Current Breaker with
Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
9. Electrical connection
Summary of Contents for 1092 Continental Induction G5
Page 1: ...U110267 04 Falcon 900s Induction USER GUIDE INSTALLATION INSTRUCTIONS ...
Page 4: ...ii ...
Page 39: ...35 Notes ...