INSTALLATION AND 
USER MANUAL 

 
Thank you for choosing Fairland Full-inverter heat pump. 
This  manual  provides  you  necessary  information  for 
optimal use and maintenance, please read it carefully and 
keep it for subsequent use. 

Summary of Contents for IPHCR13V

Page 1: ...ION AND USER MANUAL Thank you for choosing Fairland Full inverter heat pump This manual provides you necessary information for optimal use and maintenance please read it carefully and keep it for subsequent use ...

Page 2: ......

Page 3: ... 10 2 1 Notice before installation 10 2 2 Installation instruction 11 2 3 Trial after installation 14 2 4 Maintenance and winterizing 14 3 TROUBLE SHOOTING FOR COMMON FAULTS 15 4 FAILURE CODE 16 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 17 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 18 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 19 PLEASE READ CAREFULLY AND KEEP FOR SUBSE...

Page 4: ... with the instructions 1 Use Don t put articles on the heat pump do not block the air outlet 2 Installation a This product must be kept away from any source of fire b The installation can t be in a closed environment or indoors and must be kept well ventilated 3 Transportation Storage a Secure load for transportation b This product must be stored away from any source of fire ...

Page 5: ...2 4 Maintenance notice a For repair or scrap please contact an authorized service centre b Only qualified Service Technicians are permitted to carry any service work on heat pump ...

Page 6: ...etting heating 18 40 cooling 12 30 1 3 Benefits in different modes The heat pump has three modes Booster Smart and Silence which have different advantages under different conditions MODE ADVANTAGES Booster mode Heating capacity 120 Fast heating Smart mode Heating capacity 100 20 Intelligent optimization according to ambient temperature and water temperature Energy efficient saving Silence mode Hea...

Page 7: ...hing the water union when moving the heat pump to avoid the titanium heat exchanger damage 1 4 3 Don t put obstacles in front of the air inlet and outlet of the heat pump Otherwise heating efficiency will be sharply reduced even stopping the system 1 4 4 Do not put anything into inlet or outlet do not remove fan cover 1 4 5 Do not use or store combustible gas or liquid such as thinners paint and f...

Page 8: ... by yourself 1 4 7 The main power switch should be out of the reach of Children 1 4 8 Cut off the power in a lightning storm power surges can damage heat pumps 1 4 9 Please note that the following codes are no failure codes CODES No water flow Anti Freezing Reminder Out of the operating temp range Insufficient water flow or pump blocked Abnormal outdoor power supply ...

Page 9: ...UNCTION ON OFF Power On Off Unlock 1 Press for 3 seconds to unlock lock screen 2 After screen is unlocked press to select mode Auto 12 40 Heating 18 40 Cooling 12 30 Speed Select Booster Smart mode Silence mode Up Down Adjust set temperature Note Screen lock a If no operation in 30 seconds screen will be locked b When HP is off screen will be dark and 0 will be displayed c Press for 3 seconds to l...

Page 10: ...e 1 Power On Press for 3 seconds to light up screen then press to power on heat pump 2 Adjust Set Temperature When screen is unlocked press or to display or adjust the set temperature 3 Mode Selection Press to select mode a Auto adjustable temperature range 12 40 b Heating adjustable temperature range 18 40 c Cooling adjustable temperature range 12 30 Booster Smart Silence mode Water inlet tempera...

Page 11: ...hing b Compulsory Defrosting When heat pump is heating press and together for 5 seconds to start compulsory defrosting and will be flashing After defrosting will stop flashing Note Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for more than 10 minutes 2 3 Daily maintenance and winterizing 2 3 1 Daily maintenance Cut off power supply of the heat pump w...

Page 12: ...ormance Condition Air 35 C Water 28 C Humidity 80 Cooling capacity kw 7 5 8 5 11 2 Sound pressure at 1m dB A 41 5 55 2 43 3 53 9 41 0 54 4 Sound pressure at 10m dB A 21 5 35 2 23 3 33 9 21 0 34 4 Power supply 230V 1 Ph 50Hz Rated input power at air 15 C kw 0 34 2 45 0 42 3 19 0 55 4 32 Rated input current at air 15 C A 1 48 10 7 1 83 13 9 2 40 18 8 Advised water flux m h 5 7 6 5 8 5 8 10 Water pip...

Page 13: ...en moving the heat pump do not lift or hold the water union to avoid the titanium heat exchanger damage 2 INSTALLATION AND MAINTENANCE 2 1 Before installation 2 1 1 The inlet and outlet water unions can not bear the weight of soft pipes The heat pump must be connected with hard pipes 2 1 2 In order to guarantee the heating efficiency the water pipe length should be 10m between the pool and the hea...

Page 14: ...ance Please refer to below A distance at least 500 mm is required between the heat pump and the walls shrubs equipment etc This will provide sufficient intake air In order to prevent air recirculation the gap of air outlet should not be less than 1000 mm We do not recommend placing the unit under the eaves deck or porch as this will result in recirculation of the exhaust air or low efficiency of t...

Page 15: ...s running there will be condensation water discharged from the bottom 2 2 3 Wiring protecting devices and cable specification Connect to appropriate power supply the voltage should comply with the rated voltage of the products It should be well resistance grounding Wiring must be connected by a professional technician according to the circuit diagram Set breaker or fuse according to the local code...

Page 16: ...1 24 Power Cord mm2 3 2 5 3 4 3 6 Signal cable mm2 3 0 5 3 0 5 3 0 5 NOTE The above data is adapted to power cord 10m If power cord is 10m wire diameter must be increased The signal cable can be extended to 50m at most A For power supply 230V 50Hz Distribution Box Customer prepare Power Cord Swimming Pool Heat Pump Wiring Board Power Supply 400V 50Hz Breaker Distribution Box Customer prepare Power...

Page 17: ...mp and check for any leakage of water Power on and press the ON OFF button of the heat pump and set desired temperature in the thermostat In order to protect the heat pump the heat pump is equipped with start delay function When starting the heat pump the fan will start to run in 3 minutes in another 30 seconds the compressor will start to run After pool heat pump starts up check for any abnormal ...

Page 18: ...aker Fan running but with insufficient heating evaporator blocked Remove the obstacles Air outlet blocked Remove the obstacles 3 minutes start delay Wait patiently Display normal but no heating Set temp too low Set proper heating temp 3 minutes start delay Wait patiently If above solutions don t work please contact your installer with detailed information and your model number Don t try to repair ...

Page 19: ... cooling mode 7 P0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failure 12 P5 Gas return temp sensor failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Res...

Page 20: ...17 FOR INSTALLERS AND PROFESSIONALS APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Page 21: ...18 FOR INSTALLERS AND PROFESSIONALS APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Page 22: ...19 FOR INSTALLERS AND PROFESSIONALS APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Page 23: ... filtration clock A Water pump timer B Water pump wiring of Heat Pump Note The installer should connect A parallel with B refer to the picture above To start the water pump condition A or B is connected To stop the water pump both A and B should be disconnected ...

Page 24: ......

Page 25: ...Version C00IVr32 ...

Reviews: