5.2.2. Heat pump installation.
➢
The frame must be fixed by bolts
(M10)
to concrete foundation or brackets. The concrete foundation
must be solid; the bracket must be strong enough and anti
-
rust treated;
➢
The heat pump needs a water pump
(Supplied by the user)
. The recommended pump specification
-
flux:
refer to Technical Parameter, Max. lift
≥10m