background image

Installation  and  user  manual

 

 

                                                                                                                                                          12

 

 

4. TRANSPORTATION

 

4.1. When storing or moving the heat pump, the heat pump should be at the upright position.

 

 
 
 
 
 
 
 

 

4.2. When moving the heat pump, do not lift the water union since the titanium heat exchanger inside the 

heat pump will be damaged.

 

 

 

 

4.3

 

Before moving the Commercial inverter, remove the screws which fixed on the pallet and remove the 
pallet.

 

 

1. Remove the screws which fixed on the pallet 

 

   

 

2. Deliver with fork lift 

 

 

5. INSTALLATION AND MAINTENANCE

 

 

The heat pump must be installed by a professional team. The users are not qualified to install by 

themselves, otherwise the heat pump might be damaged and risky for users’ safety.

 

Summary of Contents for IPHC150T

Page 1: ...to ensure proper use installation and maintenance Ithomis Str 6 Chalandri GR 15231 Athens Greece el 302106715510 302117007269 302117007270 Fax 302106542877 Website www ecofer com gr INSTALLATION USER...

Page 2: ...Installation and user manual 2...

Page 3: ...n instructions 8 2 3 Daily maintenance and winterizing 10 3 TECHNICAL SPECIFICATION 11 4 TRANSPORTATION 12 5 INSTALLATION AND MAINTENANCE 12 5 1 Notice before installation 13 5 2 Installation instruct...

Page 4: ...The heat pump will have ideal performance in the operation range Air 15 25 1 3 Advantages of different modes The heat pump has two modes Smart and Silence They have different advantages under differen...

Page 5: ...to heat the pool water It can NEVER be used to heat other flammable or turbid liquid 2 Don t lift the water union when moving the heat pump since the titanium heat exchanger inside the heat pump will...

Page 6: ...y abnormal circumstances occurred e g abnormal noises smells smokes and leakage of electricity switch off the main power immediately and contact your local dealer Don t try to repair the heat pump by...

Page 7: ...ating range Insufficient water flow or pump blocked Power abnormal 2 OPERATIONS 2 1 Notice before using 2 1 1 For longer service life please ensure water pump is on before heat pump starts to work and...

Page 8: ...Silence mode Up Down Adjust set temperature Note Screen lock a If no operation in 30 seconds screen will be locked b When HP is off screen will be dark and 0 will be displayed c Press for 3 seconds t...

Page 9: ...heat pump 2 Adjust Set Temperature When screen is unlocked press or to display or adjust the set temperature 3 Smart Silence mode selection Smart mode as default will be activated when heat pump is o...

Page 10: ...ly check the last page 2 3 Daily maintenance and winterizing 2 3 1 Daily Maintenance Please don t forget to cut off power supply of the heat pump Please clean the evaporator with household detergents...

Page 11: ...sor DC inverter Heat exchanger Spiral titanium tube in PVC Casing Aluminum alloy Fan direction Vertical Power supply 400V 3 Ph 50Hz Rated input power at air 15 C kW 2 20 8 03 4 69 17 6 Rated input cur...

Page 12: ...ger inside the heat pump will be damaged 4 3 Before moving the Commercial inverter remove the screws which fixed on the pallet and remove the pallet 1 Remove the screws which fixed on the pallet 2 Del...

Page 13: ...e heat pump must be connected with hard pipes 5 1 2 In order to guarantee the heating efficiency the water pipe length should be 10m between the pool and the heat pump 5 2 Installation instruction 5 2...

Page 14: ...ation or brackets The concrete foundation must be solid the bracket must be strong enough and anti rust treated The heat pump needs a water pump Supplied by the user The recommended pump specification...

Page 15: ...mp Wiring must be connected by a professional technician according to the circuit diagram Set breaker or fuse according to the local code leakage operating current 30mA The layout of power cable and s...

Page 16: ...l 16 Step 2 Power cord must be passed through below 3 holes Connect the wire through three holes Restore the internal panel Fix the internal panel by two screws Restore the panel Fix the panel by thre...

Page 17: ...le specification MODEL IPH150T IPH300T Breaker Rated Current A 23 45 Rated Residual Action Current mA 30 30 Fuse A 23 45 Power Cord mm2 5 6 5 16 Signal cable mm2 3 0 5 3 0 5 NOTE The above data is ada...

Page 18: ...in the thermostat In order to protect the heat pump the heat pump is equipped with start delay function When starting the heat pump the fan will start to run in 3 minutes in another 30 seconds the co...

Page 19: ...N Please don t try to repair the heat pump by yourself to avoid any risk 7 FAILURE CODE NO DISPLAY NOT FAILURE DESCRIPTION 1 E3 No water protection 2 E5 Power supply excesses operation range 3 E6 Exce...

Page 20: ...ent sensor failure 18 PA Restart memory failure 19 F1 Compressor drive module failure 20 F2 PFC module failure 21 F3 Compressor start failure 22 F4 Compressor running failure 23 F5 Inverter board over...

Page 21: ...Installation and user manual 21 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...

Page 22: ...th filtration clock A Water pump timer B Water pump wiring of Heat Pump Note The installer should connect A parallel with B as above picture To start the water pump condition A or B is connected To st...

Page 23: ...Installation and user manual 23 8 Wifi setting 1 APP Download Android mobile please download from iphone please download from 2 Account registration a Registration by Cell phone number Email...

Page 24: ...Installation and user manual 24 b Cell phone number registration 3 Create family Please set family name and choose the room of device...

Page 25: ...he screen once Wifi connection success c If connect fails please make sure your network name and password is correct And your router mobile phone and device are as close as possible d Wifi rebinding W...

Page 26: ...and user manual 26 More share devices Indicate the status of Heating Heating capacity percentage Select The current swimming pool water temperature The setting temperature Timer Select Smart Silence...

Page 27: ...manual 27 6 Share devices to your family members After binding if your family members also want to control the device Please let your family members register the APP first and then the administrator...

Page 28: ...Installation and user manual 28 Then your family members can log in as below Notice 1 The weather forecast is just for reference 5 APP is subject to updating without notice...

Page 29: ...Ithomis Str 6 Chalandri GR 15231 Athens Greece el 30210 6715510 30211 7007269 30211 7007270 Fax 302106542877 Website www ecofer com gr Version C00IW...

Reviews: