Page: 46 - Installation Manual - NC-200 PB
PAR47
Analog voltage for slow axis feedrate in the positive direction.
Value range: Between 0 and 10V.
PAR48
Analog voltage for slow axis feedrate in the negative direction.
Value range: Between 0 and 10V.
PAR49
Analog voltage for fast axis feedrate in both directions.
Value range: Between 0 and 10V.
PAR50
Language selection for the messages appearing on the LCD display.
0 = English; 1 = Spanish; 2 = German; 3 = French; 4 = Italian;
5 = Portuguese; 6 = User defined.
PAR51
Digits
8
If =1, the EDITOR no longer shows the "attributes" page for
machines or programs that do not require those resources.
This unit will assume the attribute values set by parameters
PAR29 (d) and PAR30 (t).
7
On "A" and "A1" models with an electrical signal from the pressure gage,
the top dead point may be preset with the "D" variable, timing the ram-
up movement. Productivity may be improved when dealing with small
parts:
If =1, to activate this feature.
If =0, to deactivate this feature. The block change is only forced when
the ram reaches the top dead point, I13=1.
6 to 3
Not being used at this time. They all must be set to "0".
2
To turn on (=0) or off (=1) the confirmation beep when pressing the
keys.
1
Program memory lock, 0 = unlocked; 1 = locked.
PAR52
Loading of the user defined language.
When accessing this parameter, the NC requests the password.
After keying 5564, the NC is ready to receive the file containing the
user defined language.