NC-200 PB - Installation Manual - Page: 45
PAR40
Proportional gain Kv of the position loop in the positive direction if
PAR46(5) = 1. Axis controlled in closed loop.
(See section 5.2).
Possible values: Between 0 and 255.
PAR41
Proportional gain Kv of the position loop in the negative direction if
PAR46(5) = 1. Axis controlled in closed loop.
(See section 5.2).
Possible values: Between 0 and 255.
PAR42
Conversion factor of the pressure gage.
Kp = Tons/volt.
Possible values: Between 0 and 99.9
PAR44
Minimum analog voltage set for movements in the positive direction
(only if closed loop). Dynamic improvement with proportional hydraulic
valves that usually require a considerable voltage threshold in order to
allow a linear response.
Possible values: Between 0V and 10V
PAR45
Minimum analog voltage set for movements in the negative direction
(only if closed loop). Dynamic improvement with proportional hydraulic
valves that usually require a considerable voltage threshold in order to
allow a linear response.
Possible values: Between 0V and 10V
PAR46
Axis control.
Digit
8, 7, 6
Not being used at this time. They must be set to "0".
5
If =1, axis controlled in closed loop (the enable is maintained within
the in-position zone
If =0, "Axis controlled in open loop". The enable is canceled when
reaching the in-position zone. It is restored if the axis gets out
of position.
4
Not being used at this time. It must be set to "0".
3
Use analog voltage for feedrate.
2
Sign of the positive movement. Change it if the axis does not get in
position.
1
Bipolar voltage for speed.