Page: 42 - Installation Manual - NC-200 PB
PAR28
Top dead point. Default value of the relative distance between the punch
and the die to return ram after each bend.
Possible values:
From 0.0001mm to 9999.9999 mm
(From 0.000005" to 393.700").
It may be forced from the editor. "B" and "C" models.
PAR29
Default value of the delay of the punch in contact with the sheet metal
at the end of the bend.
Possible values: between 0 seconds to 9.9 seconds.
It may be forced from the editor. It is referred to as the "d" attribute.
PAR30
Default value of the delay applied to the X axis movement before the next
positioning move (only if when moving towards X-).
Possible values: between 0 seconds to 9.9 seconds.
It may be forced from the editor. It is referred to as the "t" attribute.
PAR31
(Model "A"). Configuration of the 3 inputs for external key simulation
through pins 16, 35 and 36 of 37-pin connector X2.
· To assign a key to input I16:
Press
and then the key to be assigned.
· To assign a key to input I35:
Press
and then the key to be assigned.
· To assign a key to input I36:
Press
and then the key to be assigned.