1
If = 0, The selected axis moves in rapid in the positive direction up tot
home switch and returns at slow speed until detecting the home pulse.
If = 1, the home position is floating.
When pressing
, it requests the password (719200).
PAR 16
It sets the value of the leadscrew backlash to compensate for.
Range of possible values: ±99999.999
PAR 17
It sets how the leadscrew backlash compensation will be applied with
unidirectional approach.
0 = There is no unidirectional approach.
X axis: 2 = It will be applied when moving in the positive direction.
Y axis: 1 = It will be applied when moving in the negative direction.
PAR18
It indicates the multiplying factor applied onto leadscrew backlash,
PAR16, in order to calculate the overshooting distance in unidirectional
approach. In order to assure that the return will be done at slow speed,
set P26 > P16 x P18
Possible values: 1 to 255
PAR19
Indicates the reduction factor of the Kv gain. It affects exponentially in
base 2.
For example: PAR19 = 3 means a reduction factor of 2
3
= 8.
Possible values: between 0 and 20. Recommended value: 10
Positive (X)
Negative (Y)
+
0
-
+
0
-