Page: 12 - Installation Manual - NC-200 PB
X2.
- SUB-D type 37 pin female connector to connect the digital inputs and
outputs as well as the analog outputs.
X3.
- SUB-D HD type 15-pin female connector for X axis feedback device.
X4.-
SUB-D HD type 15-pin female connector for Y axis feedback device.
X5.-
SUB-D HD type 15-pin female connector for 2nd axis feedback device.
auxiliary Y' axis (only on model "B").
X7.
- SUB-D type 9 pin male connector for the RS-232-C serial line connection.
WARNING
Do not handle the connectors while the unit is under power.
Before handling the connectors (mains, feedback, etc.) make
sure that the unit is not under power.
It is NOT enough to turn the display off by using the
key
at the keyboard.
1.3
GENERAL TECHNICAL CHARACTERISTICS
Universal Power Supply between 100V AC and 240V AC ±10% at a mains
frequency between 45 Hz and 400Hz, between 120Vdc and 300Vdc
Mains frequency of 0 Hz (DC) and from 45 Hz to 400 Hz.
Power outages of up to 20 milliseconds.
10-year memory backup of installation parameter even when the unit is off.
The operating temperature inside the DRO enclosure must be between 5º C and
45º C (41ºF and 113ºF).
The storage temperature inside the DRO enclosure must be -25º C and +70º C
(-13º F and 158º F).
Maximum relative humidity: 95% non condensing at 45ºC (113ºF).
Front Panel Sealing: IP54 (DIN 40050), Rear panel: IP4X (DIN40050) except
for built-in models in which case is: IP20.