Changing the Set Point of the temperature on the controller 

The  unit  comes  with  a  factory  default  set  point  (  32°F  Refrigerators).  These  set 
values  will  make  the  unit  perform  at  its  maximum  capacity.  Therefore,  it  is  not 
recommended to change the set point. If set point needs to be changed, follow the 
next steps.  

1.

 

Push the SET button for one second. You should see a flashing number. 
Release the button. 

 

 
2.

 

Press  the  up  and  down  arrows  to  increase  or  decrease  the  set 
temperature. Then press the set button to save the new set point. 

Note: 

The  maximum  value  you  can  set  in  the  controller  is:  For  refrigerators:  5°C 
(40°F) 

3.

 

If  you  wish  decrease  the  value  of  the  set  point  for  a  new  temperature, 
press the button DOWN arrow (see the picture below). Press this button 
to  reach  the desired  value.  Release  the  button  and  then  press  the SET 
button to keep, and save, the new value. 

Note: 

The minimum  value you  can  set  in  the  controller  is:  For  refrigerators:  -1°C 
(30°F) 

Manual Defrost 

To select manual defrost, hold the button DOWN arrow for 5 seconds. The snow 
flake icon will appear on the display. When this icon is solid it indicates that the 
equipment is in Defrost mode. 

 

To  exit  manual  defrost,  hold  the  DOWN  button  arrow  for  5  seconds.  The  snow 
flake icon will turn off. Wait 2 minutes for the compressor to start 

MAINTENANCE 

4.1 General safety rules. 
4.2 Machine cleaning and maintenance routine. 
4.3 Machine disposal.

 

4.1

 

 General safety rules 

 

Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY 
associated with the compressor or cost to replace the compressor! 

Proper  cleaning  of  stainless  steel  requires  soft  cloths  or  plastic  souring  pads. 
Never use steel pads, wire brushes or scrapers! 

 

 

Summary of Contents for FMT-27-12-N

Page 1: ...17 REFRIGERATORS AND FREEZERS TABLES Manual Instructions PROFESSIONAL LINE SNACK LINE DOCUMENT CODE 602305M0065 Manual instructions Installation and Operation Manual de instrucciones Uso y mantenimien...

Page 2: ...er s identification label description 7 2 5 Installation and assembly 7 2 6 Connections 8 OPERATION 8 3 1 General information 8 3 2 Control panel description 8 3 2 1 Analog Thermostat 8 3 2 2 Electron...

Page 3: ...16 2 6 Conexiones 17 OPERACION 17 3 1 Informaci n General 17 3 2 Descripci n del panel de control 17 3 2 1 Termostato anal gico 17 3 2 2 Control electronico 18 3 3 Configuraciones del Equipo 19 MANTE...

Page 4: ...704x766x929 115 2 7 8 8 Oz 1449 204 220 1 9 FST 36 10 N 1 6 36 1 3 x 30 x 36 1 2 923x766x929 115 2 7 8 8 Oz 1449 204 220 1 9 FST 48 12 N 1 4 48 1 3 x 30 x 36 1 2 1228x766x929 115 5 0 9 8 Oz 1666 289 2...

Page 5: ...n pan for efficient condensation 1 2 Important safety information DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensi...

Page 6: ...de Contact the dealer through which you purchased the unit Check the compressor compartment housing and visually inspect the refrigeration package Be sure lines are secure and base is still intact 2 3...

Page 7: ...loor strong enough to support the total weight of the unit and contents For the most efficient operation be sure to provide good air circulation inside and outside of the unit INSIDE CABINET The first...

Page 8: ...e 422 Appliances OPERATION 3 1 General information 3 2 Control panel description 3 3 Machine settings and programs 3 1 General information Good air flow inside the cabinet is critical Do not block air...

Page 9: ...or an error code call for technical service They will help you fix the problem FIGURE 1 Thermostat it s located inside the unit in the right side FIGURE 2 1 For best performance knob should be pointin...

Page 10: ...e the picture below Press this button to reach the desired value Release the button and then press the SET button to keep and save the new value Note The minimum value you can set in the controller is...

Page 11: ...are de greasing agents available for refrigeration use and specifically for the condenser coils The condenser coil may require a spray with the de greasing agent and then blown through with compresse...

Page 12: ...till located inside the drain pan The leveling of the unit is important as the units are designed to drain properly when on a level surface if your floor is not level this can also cause drain problem...

Page 13: ...must be 38 C 100 F f To insure proper air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit g If FREEZER check that the temperature is not Cel...

Page 14: ...ci n eficiente 1 2 Informaci n de seguridad El equipo debe ser apagado y desconectado de la fuente de alimentaci n cuando realizar el mantenimiento reparaci n o limpieza de la unidad condensadora Si l...

Page 15: ...el equipo notif quelo de inmediato a la empresa transportadora mediante un llamado telef nico as como tambi n de manera escrita Solicite una inspecci n por parte de la compa a transportadora si el eq...

Page 16: ...Remoci n de la placa de datos anular la garant a 2 5 Instalaci n y Ensamble Las unidades presentadas en este manual est n dise adas para uso interior solamente Aseg rese de que la ubicaci n elegida ti...

Page 17: ...el aparato El equipo debe ser instalado en un circuito protegido por sobrecargas y o cortos circuitos as como por variaciones de voltaje IMPORTANTE El contacto o enchufe debe tener conductor de tierra...

Page 18: ...DE CONGELAC N Ejemplo FUF_ ACBR_MSP F Despu s de conectar su unidad active el interruptor situado en el controlador La pantalla se encender mostrando la temperatura dentro de la unidad Adem s los icon...

Page 19: ...l SET POINT para una nueva temperatura presione el bot n de flecha hacia abajo Pulse este bot n para alcanzar el valor deseado suelte el bot n y luego presione el bot n de SET para guardar el nuevo va...

Page 20: ...onecte la m quina Quite el panel delantero inferior y cuidadosamente Deslice hacia afuera la unidad condensadora La bobina del condensador requiere una limpieza regular recomendado cada 30 a 60 d as d...

Page 21: ...del evaporador Cada drenaje puede ser removido o desconectado Si percibe excesiva acumulaci n de agua en el interior de la unidad aseg rese de que est conectado el tubo de desag e del evaporador a la...

Page 22: ...ontrol no marque alguna alarma d Verifique que el SET POIT de temperatura es el correcto e Verifique que no existe obstrucci n al flujo del aire en el interior del equipo f Verifique que el ventilador...

Page 23: ...23 fagorindustrial com ELECTRIC DIAGRAM DIAGRAMA ELECTRICO REFRIGERATION TABLES MESAS REFRIGERACION 27 72...

Page 24: ...24 fagorindustrial com FREZZER TABLES MESAS CONGELACION 27 60...

Page 25: ...25 fagorindustrial com ANEXOS...

Page 26: ...26 fagorindustrial com...

Page 27: ...Phone 866 463 2467 Circuito Exportaci n N 201 Parque Industrial Tres Naciones San Lu s Potos S L P M xico Tel fono Planta S L P 52 444 137 0500 Ext 538 Sin costo 01 800 00 FAGOR MULTI SOLUTION MANUFA...

Reviews: