RIOW REMOTE MODULES.
(CANOPEN
PROTOCOL).
5.10
RIOW-4AI module. Module of 4 analog inputs.
Expansion module with four ±10 V DC analog inputs. The module has an LED indicating the
status for each input.
The 24 V DC needed to power the module comes from the previous module (inputs, outputs
module or power supply module) through the side power supplying jumpers). Likewise, this
module can also power the next module through the same jumpers. This module, by itself,
does not generate any voltage; it just receives the voltage generated by the previous RIOW-
PS24 module and passes it on to the next module.
4
8
1
5
2
6
3
7
C
A
D
B
Ground connection.
Analog input ·3·.
Ground connection.
Analog input ·1·.
Ground connection.
Analog input ·4·.
Ground connection.
Analog input ·2·.
LED's indicating an error at the
analog inputs.
Jumpers to power the next module.
Jumpers to power the module.