background image

 

4. Commissioning the equipment 

 

21 

 

 

4.

 

Commissioning the equipment 

Before commissioning, the equipment must have been correctly installed by the supplier.    

The equipment must be installed as described in this manual. It must be properly connected to the 

water supply source, drain outlet, electrical supply and, for gas equipment, to the gas supply, under 

a combustion gas exhaust system. It is very important to level and adjust the door as one of the 

adjustable parameters is the humidity control sensor, which will have an impact on the operation 

of the oven.  

After  making  the  necessary  adjustments,  the  oven  has  an  Autotest  programme,  which 

automatically calibrates and tests the different components for correct operation. 

 

Running the Autotest programme  

The  Autotest  programme  is  a  function  that  allows  the  appliance  to  automatically  adapt  to  the 

ambient conditions. During this process, it automatically adjusts the operating parameters to the 

altitude at which the oven is installed. It calibrates the humidity sensor and recalculates the boiling 

point for the correct operation of the ovens with integrated steam generator.  

The  first  time  the  oven  is  switched  on,  it  needs  to  perform  the  Autotest 
programme. The 

Autotest

 must be validated by pressing the control button.  

   

Once the message has been validated, the process will begin.  

First of all, remember to empty the interior of the cooking chamber, ensuring that 
transport  materials  and  documentation  supplied  with  the  oven  have  been 
removed.  

Once the validation is complete and the door has been closed, the chamber temperature is checked 
and the programme continues. The following diagram shows the steps leading to the validation 
and completion of the Autotest programme.  

 

  

 

 

 

To end the Autotest, press the control knob or the 

Start/Stop 

button.

Steam generation 
settings 

End of 
programme 

Cooking 
chamber heating 

Boiler filling 
 ( models) 

Summary of Contents for C A-061-E

Page 1: ...ES MANUAL DE INSTALACION ORIGINAL Antes de proceder a la puesta en servicio del aparato leer detenidamente las instrucciones de este manual 12308672...

Page 2: ...1 Transporte y desembalaje 6 3 2 Emplazamiento y nivelaci n 7 3 3 Distancias m nimas 8 3 4 Peso de los aparatos 9 3 5 Instalaci n de modelos sobremesa 10 3 6 Conexi n el ctrica 11 3 7 Conexi n de gas...

Page 3: ...laci n de la misma La instalaci n ajuste incorrecto el servicio o el mantenimiento inapropiado del aparato as como la manipulaci n de este pueden provocar tanto da os materiales como lesiones Est abso...

Page 4: ...adopte las siguientes precauciones Toque nicamente los mandos de control y el asa Las partes externas met licas y el cristal de la puerta alcanzan temperaturas muy altas 60 C Al abrir la puerta h gal...

Page 5: ...r a la puesta en servicio del aparato leer detenidamente las instrucciones de este manual No almacenar ni utilizar gases o l quidos explosivos cerca del aparato ni introducir l quidos con contenido al...

Page 6: ...necesarias y utilizar en equipamiento de prevenci n facilitado ADVERTENCIA Antes de manipular los aparatos tenga en cuenta su centro de gravedad Existe peligro de lesiones y aplastamiento puesto que e...

Page 7: ...mente ventilado de acuerdo con la reglamentaci n en vigor para impedir la formaci n de concentraciones inadmisibles de sustancias nocivas en el lugar en el que est instalado Se deber instalar el equip...

Page 8: ...nexi n de seguridad del aparato se active Colocar el horno a una distancia de la pared que sea c moda para poder realizar las conexiones el ctricas e h dricas y para realizar trabajos de reparaci n y...

Page 9: ...23 E 200 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201...

Page 10: ...no utilizar contenedores de carga con l quidos o alimentos para cocinar que se conviertan en fluidos por calentamiento a niveles superiores que aquellos que pueden ser f cilmente observables Las bande...

Page 11: ...rruptor autom tico magnetot rmico de corte omnipolar adecuadamente dimensionado con un m nimo de 3 mm de apertura entre contactos Este dispositivo debe usarse para desconectar el aparato en trabajos d...

Page 12: ...Hz 3x2 5mm2 N T 16 9A 20A 300 mA 11 7 230V 3 50 60Hz 3x6mm T 29 4A 32A 300 mA 200V 3 50 60Hz 3x6mm T 33 8A 40A 300 mA 230V 1 50 60Hz 2x10mm T 50 9A 50A 300 mA C_A 062 E C_AW 062 E C_AP 0623 E C_APW 06...

Page 13: ...KW POTENCIA GAS kcal h Hi G30 G31 G20 15 488 BTU h Hi G30 G31 G20 61 460 kW Hi G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230V 1 50 60Hz 2x1 5mm T 16A POTENCIA EL CTRICA 2 75 KW POTEN...

Page 14: ...ica necesaria mbar Presi n m nima mbar Presi n m xima mbar Modelos 061 Modelos 101 Modelos 201 Modelos 102 Modelos 202 G 20 m h Gas Natural 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg h Butano 28 3...

Page 15: ...perjudiciales para la salud Se aconseja la instalaci n de una campana extractora para la extracci n de humos y vapores cumpliendo la norma UNE 100165 2004 Convendr a que la campana sobresaliera 200 4...

Page 16: ...n disposiciones locales La alimentaci n de gas al horno s lo se debe habilitar cuando el sistema de extracci n est activado En caso de que falle el funcionamiento del sistema de extracci n ventilaci n...

Page 17: ...es encima del aparato peligro de incendio 3 9Conexi n de agua Conectar al aparato s lo con agua potable Realizar la conexi n a la red de agua por los puntos indicados Fig 11 utilizando un nuevo conjun...

Page 18: ...el tratamiento del agua en los casos que seg n la experiencia del grado de calcinaci n sea elevado sin carga de cloruro Sistemas H Intercambio de iones o Kleensteam Desaconsejamos encarecidamente el...

Page 19: ...g 13 Fig 14 se debe realizar de forma que la salida del desag e instalada quede por debajo de la salida del horno con una inclinaci n suficiente para asegurar su drenaje 5 3 Asegurarse que los agujero...

Page 20: ...e por encima de la salida del horno provoca que el agua rebose por el colector de aguas del horno D 70 mm Fig 14 Modelos 201 y 202 Una vez instalado el KIT desag e su descarga al desag e general debe...

Page 21: ...pta autom ticamente a las condiciones del entorno En dicho proceso el horno ajusta sus par metros de funcionamiento a la altitud a la que se encuentra instalado el aparato Calibra el sensor de humedad...

Page 22: ...EN ORIGINAL INSTALLATION MANUAL Carefully read the instructions in this manual before using the appliance for the first time...

Page 23: ...Transport and unpacking 6 3 2 Positioning and levelling 7 3 3 Minimum distances 8 3 4 Appliance weights 9 3 5 Installation of table top models 10 3 6 Electrical connection 11 3 7 Gas connection only...

Page 24: ...of the appliance as well as improper handling of the appliance can cause damage to property and injury It is absolutely forbidden to alter circumvent remove or bypass safety devices Failure to comply...

Page 25: ...eat resistant clothing when handling objects inside the cooking chamber Remove the probe from the core before removing the trays and place it in its holder ensuring that the cable does not obstruct th...

Page 26: ...ar the appliance or introduce liquids containing alcohol into the appliance When the oven is hot do not open the door abruptly danger of burns due to the existence of hot vapours Do not pour cold wate...

Page 27: ...tallation Take all necessary preventive measures and use the preventive equipment provided WARNING Before handling the appliance be aware of the centre of gravity There is a risk of injury and crushin...

Page 28: ...a sufficiently ventilated room in accordance with the regulations in force to prevent the formation of inadmissible concentrations of harmful substances in the place where it is installed The equipme...

Page 29: ...ce may cause the safety cut out of the appliance to activate Place the oven at a convenient distance from the wall for electrical and water connections and for repair and maintenance work A distance o...

Page 30: ...3 E 200 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201...

Page 31: ...BURN HAZARD To avoid scalding do not place containers containing liquids or foods that become liquid when heated at a height that is not easily visible Trays can be placed in the oven at a maximum he...

Page 32: ...opening of 3 mm between contacts must be installed in an easily accessible location next to the equipment This device must be used to disconnect the equipment for installation work repairs cleaning a...

Page 33: ...0V 3 50 60Hz 3x6mm T 29 4A 32A 300mA 200V 3 50 60Hz 3x6mm T 33 8A 40A 300mA 230V 1 50 60Hz 2x10mm T 50 9A 50A 300mA C_A 062 E C_AW 062 E C_AP 0623 E C_APW 0623 E 400V 3N 50 60Hz 3x6mm2 N T 32 9A 40A 3...

Page 34: ...kcal h Hi G30 G31 G20 15 488 BTU h Hi G30 G31 G20 61 460 kW Hi G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230V 1 50 60Hz 2x1 5mm T 16A ELECTRICAL POWER 2 75 KW GAS POWER kcal h Hi G30...

Page 35: ...essure mbar Maximum pressure mbar Models 061 Models 101 Models 201 Models 102 Models 202 G 20 m h Natural Gas 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg h Butane 28 30 25 35 0 998 1 498 2 995 2 91...

Page 36: ...ful to health It is advisable to install an exhaust hoodfood for the extraction of fumes and vapours in compliance with the standard UNE 100165 2004 The hood should protrude 200 400mm from the front o...

Page 37: ...out the installation according to local regulations The gas supply to the oven must only be enabled when the extraction system is activated In the event of a malfunction of the extraction ventilation...

Page 38: ...equipment as this is a fire hazard 3 9Water connection Connect the appliance to drinking water only Connect to the water mains at the points indicated Fig 11 using a new set of hoses supplied by the...

Page 39: ...delay with common salt When selecting filter systems A B C D we recommend the manufacturer BRITA Before connecting look for the sticker indicating the water inlet UK only IRN R160 To be carried out b...

Page 40: ...of the steam generator in a limited period of time 0 7 l s Average waste water temperature 65 C Fig 13 Table top models 061 101 102 If the drainage kit is installed above the oven outlet this causes...

Page 41: ...3 Installation instructions 20 Once the drain has been installed its discharge to the general drain must be of type AA AB or AD in accordance with standard EN1717...

Page 42: ...ambient conditions During this process it automatically adjusts the operating parameters to the altitude at which the oven is installed It calibrates the humidity sensor and recalculates the boiling p...

Page 43: ......

Page 44: ...FR GUIDE D INSTALLATION ORIGINAL Avant de proc der la mise en service de l appareil lire attentivement les consignes de ce manuel...

Page 45: ...1 Transport et d ballage 6 3 2 Emplacement et nivelage 7 3 3 Distances minimales 8 3 4 Poids des appareils 9 3 5 Installation des mod les de table 10 3 6 Connexion lectrique 11 3 7 Raccordement au gaz...

Page 46: ...tions doivent toujours tre effectu s par un TECHNICIEN AUTORIS conform ment aux r glementations en vigueur dans chaque pays et le fabricant ne peut tre tenu responsable d une installation incorrecte U...

Page 47: ...brancher l alimentation en lectricit et en eau Risque de br lures et de blessures Pendant la cuisson et jusqu ce que toutes les parties de l appareil aient refroidi prenez les pr cautions suivantes To...

Page 48: ...ures Avant de proc der la mise en service de l appareil lire attentivement les consignes de ce manuel Ne stockez pas et n utilisez pas de gaz ou de liquides explosifs proximit de l appareil et n intro...

Page 49: ...pr ventives n cessaires et utilisez les quipements de pr vention fournis AVERTISSEMENT Avant toute manipulation des appareils tenez compte de leur centre de gravit Il existe un risque de blessures et...

Page 50: ...isamment ventil conform ment la r glementation en vigueur pour viter la formation de concentrations inadmissibles de substances nocives dans le lieu o il est install Il faudra tenir compte des dimensi...

Page 51: ...entra ner l activation du dispositif de s curit de l appareil Placer le four une bonne distance du mur pour les raccordements lectriques et d eau et pour les travaux de r paration et d entretien Une...

Page 52: ...E 200 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201 G...

Page 53: ...lures n utilisez pas de r cipients de charge contenant des liquides ou des aliments de cuisson qui deviennent fluides en chauffant des niveaux sup rieurs ceux qui peuvent tre facilement observ s Les p...

Page 54: ...s appropri es avec un cartement minimal des contacts de 3 mm doit tre install proximit de l appareil et tre facilement accessible Ce dispositif doit tre utilis pour teindre l appareil pendant les trav...

Page 55: ...20A 300mA 11 7 230V 3 50 60Hz 3x6mm T 29 4A 32A 300mA 200V 3 50 60Hz 3x6mm T 33 8A 40A 300mA 230V 1 50 60Hz 2x10mm T 50 9A 50A 300mA C_A 062 E C_AW 062 E C_AP 0623 E C_APW 0623 E 400V 3N 50 60Hz 3x6mm...

Page 56: ...SSANCE GAZ kcal h Hi G30 G31 G20 15 488 BTU h Hi G30 G31 G20 61 460 kW Hi G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230V 1 50 60Hz 2x1 5mm T 16A PUISSANCE LECTRIQUE 2 75 KW PUISSANCE...

Page 57: ...namique n cessaire mbar Pression minimale mbar Pression maximale mbar Mod les 061 Mod les 101 Mod les 201 Mod les 102 Mod les 202 G 20 m h Gaz naturel 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg h...

Page 58: ...bustion qui sont nocifs pour la sant Il est conseill d installer une hotte aspirante pour l extraction des fum es et des vapeurs conform ment la norme UNE 100165 2004 Il conviendrait que la hotte d pa...

Page 59: ...elon les r glementations locales Activer l alimentation en gaz du four uniquement lorsque le syst me d extraction est activ En cas de dysfonctionnement du syst me d extraction ventilation l alimentati...

Page 60: ...isque d incendie 3 9Raccordement l eau Raccorder l appareil uniquement sur le r seau d eau potable Effectuer le raccordement au r seau d eau par les points indiqu s Fig 11 en utilisant un nouvel ensem...

Page 61: ...l eau dans les cas o selon l exp rience le degr de calcination est lev sans charge de chlorure Syst mes H change des ions ou Kleensteam Nous d conseillons fortement l utilisation d changeurs d ions so...

Page 62: ...13 Fig 14 doit tre r alis e de mani re que la sortie de l vacuation install e soit en dessous de la sortie du four avec une inclinaison suffisante pour assurer le drainage 5 ou 3 Veiller ce que les tr...

Page 63: ...ssus de la sortie du four cela entra ne un d bordement de l eau du collecteur eau du four D 70 mm Fig 14 Mod les 201 et 202 Une fois le KIT de vidange install son vacuation dans le syst me d vacuation...

Page 64: ...elle l appareil s adapte automatiquement aux conditions de l environnement Dans ce processus le four ajuste ses param tres de fonctionnement l altitude laquelle l appareil est install Il calibre le ca...

Page 65: ...DE ORIGINAL INSTALLATIONSHANDBUCH Lesen Sie vor der Inbetriebnahme des Ger ts die Anweisungen in diesem Handbuch sorgf ltig durch...

Page 66: ...nleitung 6 3 1 Transport und Auspacken 6 3 2 Aufstellungsort und Nivellierung 7 3 3 Mindestabst nde 8 3 4 Gewicht der Ger te 9 3 5 Installation von Tischmodellen 10 3 6 Stromanschluss 11 3 7 Gasanschl...

Page 67: ...ie Reparaturen oder Umbauten m ssen stets von einem AUTORISIERTEN TECHNIKER gem den im jeweiligen Land geltenden Vorschriften durchgef hrt werden Der Hersteller haftet nicht f r eine unsachgem e Insta...

Page 68: ...getrennt werden Verbrennungs und Verletzungsgefahr Treffen Sie w hrend des Kochens und bis zur Abk hlung aller Teile des Ger ts die folgenden Vorkehrungen Ber hren Sie ausschlie lich die Bedienelemen...

Page 69: ...Lesen Sie vor der Inbetriebnahme des Ger ts die Anweisungen in diesem Handbuch sorgf ltig durch Lagern oder verwenden Sie keine explosiven Gase oder Fl ssigkeiten in der N he des Ger ts und bringen Si...

Page 70: ...ionszwecken bereitgestellten Mittel WARNHINWEIS Beachten Sie bei der Handhabung der Ger te deren Schwerpunkt Es besteht Verletzungs und Quetschgefahr da das Ger t beim Heben oder Transportieren umkipp...

Page 71: ...Sie das Ger t in einem Raum mit angemessener Bel ftung gem den geltenden Vorschriften um die Bildung von unzul ssigen Schadstoffkonzentrationen am Aufstellungsort zu vermeiden Das Ger t muss im Einkl...

Page 72: ...schaltung des Ger ts ausgel st wird Stellen Sie den Backofen in einem angemessenen Abstand von der Wand auf um Strom und Wasser anschlie en sowie Reparatur und Wartungsarbeiten durchf hren zu k nnen A...

Page 73: ...3 E 200 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201...

Page 74: ...rmeiden sollten Sie Gef e mit Fl ssigkeiten oder Lebensmitteln die beim Kochen fl ssig werden nicht oberhalb der leicht zu beobachtenden Ebenen abstellen Die Bleche werden bei Verwendung der Originalt...

Page 75: ...d von 3 mm muss leicht zug nglich in der N he des Ger ts installiert werden Dieser Schalter muss verwendet werden um das Ger t bei Installations Reparatur Reinigungs oder Wartungsarbeiten vom Netz zu...

Page 76: ...Hz 3x6 mm T 29 4 A 32 A 300 mA 200 V 3 50 60 Hz 3x6 mm T 33 8 A 40 A 300 mA 230 V 1 50 60 Hz 2x10 mm T 50 9 A 50 A 300 mA C_A 062 E C_AW 062 E C_AP 0623 E C_APW 0623 E 400 V 3 N 50 60 Hz 3x6 mm2 N T...

Page 77: ...kcal h Hi G30 G31 G20 15 488 BTU h Hi G30 G31 G20 61 460 kW Hi G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230 V 1 50 60 Hz 2x1 5 mm T 16 A ELEKTRISCHE LEISTUNG 2 75 KW LEISTUNG GAS kca...

Page 78: ...orderlicher dynamischer Druck mbar Mindestdruck mbar Maximaler Druck mbar Modelle 061 Modelle 101 Modelle 201 Modelle 102 Modelle 202 G 20 m h Erdgas 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg h B...

Page 79: ...iden Es wird empfohlen eine Dunstabzugshaube f r die Absaugung von Rauch und D mpfen gem UNE 100165 2004 zu installieren Die Dunstabzugshaube sollte 200 400 mm ber die Vorderseite des Ger ts hinausrag...

Page 80: ...muss gem den rtlichen Vorschriften erfolgen Die Gaszufuhr zum Backofen darf erst dann freigegeben werden wenn das Abzugssystem aktiviert ist Bei einer St rung des Abzugs Bel ftungssystems wird die Gas...

Page 81: ...hluss Schlie en Sie das Ger t nur an das Trinkwassernetz an Verbinden Sie das Ger t an den angegebenen Punkten Abb 11 mit dem Wassernetz unter Verwendung neuer Schl uche die vom Hersteller geliefert w...

Page 82: ...ierungsgrad erfahrungsgem hoch ist keine Chloridbelastung Systeme H Ionenaustausch oder Kleensteam Von der Verwendung von Natriumaustauschern wie sie in Geschirrsp lern blich sind raten wir aufgrund d...

Page 83: ...erden Die Installation Abb 13 und Abb 14 muss so ausgef hrt werden dass der Abfluss unterhalb des Abwasserausgangs des Ofens liegt und ein ausreichendes Gef lle 5 bzw 3 vorhanden ist um das Flie en zu...

Page 84: ...des Backofens installiert wird kann Wasser aus der Wasserauffangvorrichtung des Backofens berlaufen D 70 mm Abb 14 Modelle 201 und 202 Nach der Installation des Abflusskits muss die Ableitung in den...

Page 85: ...Funktion mit der sich das Ger t automatisch an die Umgebungsbedingungen anpasst Dabei passt der Backofen seine Betriebsparameter an die H he an in der das Ger t installiert ist Er kalibriert den Feuc...

Page 86: ......

Page 87: ...IT MANUALE D INSTALLAZIONE Leggere attentamente le istruzioni contenute in questo manuale prima di utilizzare l apparecchio per la prima volta...

Page 88: ...sporto e disimballaggio 6 3 2 Posizionamento e livellamento 7 3 3 Distanza minima 8 3 4 Peso dell apparecchiatura 9 3 5 Installazione di modelli da tavolo 10 3 6 Collegamento elettrico 11 3 7 Collegam...

Page 89: ...i assume alcuna responsabilit per un installazione impropria Un installazione errata una regolazione errata un servizio o una manutenzione inadeguati dell apparecchio cos come la manomissione dell app...

Page 90: ...reddamento di tutte le parti dell apparecchiatura prendere le seguenti precauzioni Toccare solo le manopole di controllo e la maniglia Le parti metalliche esterne e il vetro della porta raggiungono te...

Page 91: ...re in funzione l apparecchio leggere attentamente le istruzioni di questo manuale Non conservare o utilizzare gas o liquidi esplosivi nelle vicinanze dell apparecchio n introdurre liquidi contenenti a...

Page 92: ...usate l attrezzatura preventiva fornita ATTENZIONE Prima di maneggiare l attrezzatura siate consapevoli del suo centro di gravit C il rischio di lesioni e schiacciamenti poich l unit pu ribaltarsi dur...

Page 93: ...ufficientemente ventilato secondo le norme vigenti per evitare la formazione di concentrazioni inammissibili di sostanze nocive nel luogo in cui installato L attrezzatura deve essere installata second...

Page 94: ...are l attivazione dell interruttore di sicurezza dell apparecchio Posizionare il forno a una distanza comoda dalla parete per i collegamenti elettrici e idrici e per i lavori di riparazione e manutenz...

Page 95: ...0623 E 200 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A...

Page 96: ...STIONI Per evitare scottature non utilizzare contenitori di carico con liquidi o alimenti da cucina ai livelli pi alti di quelli che possono essere facilmente osservati Le teglie sono poste in forno a...

Page 97: ...inima di 3 mm tra i contatti deve essere installato in un luogo facilmente accessibile accanto all apparecchiatura Questo dispositivo deve essere utilizzato per scollegare l apparecchiatura per lavori...

Page 98: ...2 N T 16 9A 20A 300 mA 11 7 230V 3 50 60Hz 3x6mm T 29 4A 32A 300 mA 200V 3 50 60Hz 3x6mm T 33 8A 40A 300 mA 230V 1 50 60Hz 2x10mm T 50 9A 50A 300 mA C_A 062 E C_AW 062 E C_AP 0623 E C_APW 0623 E 400V...

Page 99: ...1 43 KW POTENZA GAS kcal h Hi G30 G31 G20 15 488 BTU h Hi G30 G31 G20 61 460 kW Hi G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230V 1 50 60Hz 2x1 5mm T 16A POTENZA ELETTRICA 2 75 KW PO...

Page 100: ...namica necessaria mbar Pressione m nima mbar Pressione massima mbar Modello 061 Modello 101 Modello 201 Modello 102 Modello 202 G 20 m h Gas Naturale 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg h B...

Page 101: ...evitare una concentrazione nei locali di installazione delle emissioni dannose per la salute rilasciate durante la combustione Si raccomanda l installazione di una cappa aspirante per l estrazione di...

Page 102: ...turale sotto una cappa aspirante o un soffitto di ventilazione L installazione deve essere effettuata in conformit alle norme locali L alimentazione del gas al forno deve essere abilitata solo quando...

Page 103: ...bustibili sopra l apparecchio pericolo di incendio 3 9Allacciamento idrico Collegare l apparecchio solo con acqua potabile Collegarsi alla rete idrica nei punti indicati Fig 11 utilizzando un nuovo se...

Page 104: ...mune Nella scelta dei sistemi di filtraggio A B C D raccomandiamo il produttore BRITA Prima di collegare controllare l adesivo che indica l ingresso dell acqua Solo UK IRN R160 A cura dell installator...

Page 105: ...ggio del generatore di vapore in un breve lasso di tempo 0 7 l s Temperatura media dell acqua di scarico 65 C Fig 13 Modelli da tavolo 061 101 102 Se si installa il KIT di drenaggio sopra l uscita del...

Page 106: ...3 Istruzioni per l installazione 20 Una volta installato il KIT di drenaggio il suo scarico nel sistema di drenaggio generale deve essere di tipo AA AB o AD secondo la norma EN 1717...

Page 107: ...omaticamente alle condizioni ambientali In questo processo il forno adatta i suoi parametri di funzionamento all altitudine in cui installato l apparecchio Calibra il sensore di umidit e ricalcola il...

Page 108: ...PL INSTRUKCJA INSTALACJI Uwa nie przeczytaj informacje zawarte w tej instrukcji przed pierwszym u yciem urz dzenia...

Page 109: ...lacji 6 3 1 Transport i rozpakowywanie 6 3 2 Pozycjonowanie i poziomowanie 7 3 3 Minimalne odleg o ci 8 3 4 Waga urz dze 9 3 5 Instalacja modeli na podstawie 10 3 6 Przy cze elektryczne 11 3 7 Przy cz...

Page 110: ...TECHNIKA zgodnie z przepisami obowi zuj cymi w ka dym kraju a producent nie mo e by poci gni ty do odpowiedzialno ci za niew a ciw instalacj Niew a ciwa instalacja nieprawid owa regulacja niew a ciwa...

Page 111: ...wa ych okres w bezczynno ci zaleca si od czenie urz dzenia od r d a wody i energii elektrycznej Ryzyko poparzenia i urazu Podczas gotowania i do ostygni cia wszystkich cz ci urz dzenia nale y podj nas...

Page 112: ...acja niew a ciwa obs uga lub konserwacja urz dzenia a tak e niew a ciwe obchodzenie si z urz dzeniem mog spowodowa uszkodzenie mienia i obra enia Uwa nie przeczytaj informacje zawarte w tej instrukcji...

Page 113: ...elkie niezb dne rodki zapobiegawcze i skorzystaj z rodk w ochrony BHP OSTRZE ENIE Przy obchodzeniem si z urz dzeniem nale y pami ta o rodku ci ko ci Istnieje ryzyko zranienia i zmia d enia poniewa spr...

Page 114: ...j co wentylowanym pomieszczeniu zgodnie z obowi zuj cymi przepisami aby zapobiec powstawaniu niedopuszczalnych st e szkodliwych substancji w miejscu w kt rym jest zainstalowane i u ytkowane Sprz t mus...

Page 115: ...e spowodowa aktywacj zabezpieczenia termicznego elektroniki urz dzenia Umie piec w dogodnej odleg o ci od ciany do po cze elektrycznych i wodnych oraz do prac naprawczych i konserwacyjnych Odleg o 50...

Page 116: ...00 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201 G 260...

Page 117: ...unikn oparze nie umieszczaj pojemnik w zawieraj cych p yny lub ywno kt re staj si p ynne po podgrzaniu na wysoko ci kt ra nie jest atwo widoczna i mo e utrudni wyj cie GN bez jego przechy u Tace mo n...

Page 118: ...usi by zainstalowany w atwo dost pnym miejscu obok urz dzenia Urz dzenie to musi by u ywane do od czania sprz tu do prac instalacyjnych napraw czyszczenia i konserwacji Zaleca si posiadanie funkcji bl...

Page 119: ...1 7 230V 3 50 60Hz 3x6mm T 29 4A 32A 300mA 200V 3 50 60Hz 3x6mm T 33 8A 40A 300mA 230V 1 50 60Hz 2x10mm T 50 9A 50A 300mA C_A 062 E C_AW 062 E C_AP 0623 E C_APW 0623 E 400V 3N 50 60Hz 3x6mm2 N T 32 9A...

Page 120: ...EM kcal h G30 G31 G20 15 488 BTU h G30 G31 G20 61 460 kW G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230V 1 50 60Hz 2x1 5mm T 16A MOC ELEKTRYCZNA 2 75 KW ZASILANIE GAZEM kcal h G30 G31...

Page 121: ...malne ci nienie mbar Maksymalne ci nienie mbar Modele 061 Modele 101 Modele 201 Modele 102 Modele 202 G 20 m h Gaz ziemny 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg h Butan 28 30 25 35 0 998 1 498...

Page 122: ...ania kt re s szkodliwe dla zdrowia Wskazane jest zainstalowanie okapu wydechowego do odprowadzania opar w i produkt w spalania zgodnie z norm UNE 100165 2004 Okap powinien wystawa 200 400 mm Poza fron...

Page 123: ...tedy gdy system odci gu dzia a prawid owo W przypadku nieprawid owego dzia ania systemu wyci gowo wentylacyjnego dop yw gazu do pieca musi zosta wy czony 3 8 3 Piec gazowy pod czony do kana u kominowe...

Page 124: ...nych punktach rys 11 u ywaj c nowego zestawu w y dostarczonych przez producenta Stare zespo y w y nie mog by ponownie u ywane Ci nienie wody na wlocie musi wynosi od 200 do 400 kPa 2 4 kg cm2 Zaleca s...

Page 125: ...ce powsta osady sodu Przed pod czeniem poszukaj naklejki na obudowie wskazuj cej wlot wody Tylko w Wielkiej Brytanii IRN R160 Do przeprowadzenia przez instalatora Certyfikowany podw jny zaw r bezpiecz...

Page 126: ...z wytwornicy pary w ograniczonym czasie 0 7 l s rednia temperatura ciek w 65 C Rys 13 Modele na podstawie 061 101 102 Je li zestaw drena owy jest zainstalowany nad wylotem z pieca spowoduje to przele...

Page 127: ...3 Instrukcja instalacji 20 Po zainstalowaniu odp ywu jego odprowadzanie do spustu og lnego musi by typu AA AB lub AD zgodnie z norm EN1717...

Page 128: ...e jest urz dzenie Kalibruje czujnik wilgotno ci i oblicza temperatur wrzenia w celu prawid owego dzia ania pieca ze zintegrowanym generatorem pary Przy pierwszym w czeniu piec musi wykona program Auto...

Page 129: ......

Page 130: ......

Page 131: ...1 1 2 2 3 2 1 3 2 2 5 3 6 3 1 6 3 2 7 3 3 8 3 4 9 3 5 10 3 6 11 3 7 14 3 8 15 3 9 17 3 10 18 4 21...

Page 132: ...1 3 2 2 1 5 40 C T...

Page 133: ...2 4 60 C 160 GN...

Page 134: ...2 5 2 2 A 70 dB A FAGOR...

Page 135: ...3 6 3 3 1 201 202...

Page 136: ...3 7 3 2...

Page 137: ...3 8 3 3 500 mm 500 mm 2 IPX5 3...

Page 138: ...A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201 G 260 kg C_AW 201 E 250 kg C_AW 2...

Page 139: ...3 10 3 5 4 6 5 7 1600 mm 160 cm 160 cm...

Page 140: ...3 11 3 6 H07RN F 3 mm 8 0623 400V 3N Fig 8...

Page 141: ...57 2A 63A 300mA 200V 3 50 60Hz 3x16mm T 65 8A 80A 300mA C_A 101 E C_AW 101 E C_AP 101 E C_APW 101 E 400V 3N 50 60Hz 3x6mm2 N T 27 7A 32A 300mA 19 2 230V 3 50 60Hz 3x10mm T 48 2A 50A 300mA 200V 3 50 6...

Page 142: ...460 kW Hi G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230V 1 50 60Hz 2x1 5mm T 16A 2 75 KW kcal h Hi G30 G31 G20 30 975 BTU h Hi G30 G31 G20 122 920 kW Hi G30 G31 G20 36 C_A 102 G C_AW...

Page 143: ...7 mbar mbar mbar 061 101 201 102 202 G 20 m h 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg h 28 30 25 35 0 998 1 498 2 995 2 912 5 408 G 31 kg h 37 42 5 57 5 0 984 1 476 2 951 2 869 5 329 2 m3 h 12x...

Page 144: ...2004 200 400mm AT II2H3B P 20 50 AL BG DK EE FI HR LT LV MK NO RO SE II2H3B P 20 30 BE FR II2E 3 20 25 28 30 37 CH CY CZ ES GB GR IE IT PT SI SK TR II2H3 20 28 30 37 DE LU II2E3B P 20 50 PL II2E3P 20...

Page 145: ...3 16 3 8 1 A3 3 8 2 B23 3 8 3 B13 061 101 19095581 201 19095591 102 19095590 202 19095592...

Page 146: ...3 17 400 C 3 9 11 200 400 kPa 2 4 kg cm2 250 pH 6 5 7 5 5 10 fH 0 08 mm 7 14 eH max 150 mg l 9 18 dH Cl 0 2 0 5 mg l 400 1 000 S cm Fig 11...

Page 147: ...3 18 1 2 0 2 mg l ppm 3 150 mg l ppm 400 S 4 H A B C D IRN R160 3 3 3 10 DN40 12 13 14 5 3 0 7 l s 65 C...

Page 148: ...3 19 13 061 101 102 D 70 14 201 202...

Page 149: ...3 20 EN1717 AA AB AD...

Page 150: ...4 21 4 C Concept...

Page 151: ...TR OR J NAL KURULUM KILAVUZU Cihaz ilk kez kullanmadan nce bu k lavuzdaki talimatlar dikkatlice okuyun...

Page 152: ...TASIMA VE AMBALAJDAN IKARMA 6 3 2 YERLESTIRME VE SEVIYE AYARLAMA 7 3 3 MINIMUM MESAFELER 8 3 4 CIHAZ AGIRLIKLARI 9 3 5 MASA ST MODELLERIN KURULUMU 10 3 6 ELEKTRIK BAGLANTISI 11 3 7 GAZ BAGLANTISI YALN...

Page 153: ...yanl ayarlanmas yanl servis veya bak m n n yan s ra cihaz n yanl kullan m maddi hasara ve yaralanmaya neden olabilir G venlik cihazlar n de i tirmek bozmak karmak veya devreden karmak kesinlikle yasak...

Page 154: ...rek yava a a n Pi irme haznesinin i indeki nesneleri tutarken her zaman s ya dayan kl giysiler giyin Tepsileri karmadan nce probu merkezden ekin ve kablonun tepsilerin kar lmas n engellememesini sa la...

Page 155: ...kullanmay n veya cihaz n i ine alkol i eren s v lar sokmay n F r n s cakken kap y aniden a may n s cak buhar kaynakl yanma tehlikesi S cakken haznenin i ine so uk su d kmeyin Havada olu an ses emisyo...

Page 156: ...m nleyici tedbirleri al n ve verilen koruyucu ekipman kullan n UYARI Cihaz ta madan nce a rl k merkezine dikkat edin Kald rma veya ta ma s ras nda ekipman devrilebilece inden yaralanma ve ezilme risk...

Page 157: ...mbaz tak lmal d r Cihaz kuruldu u yerde izin verilmeyen seviyelerde zararl madde konsantrasyonu olu mas n nlemek i in y r rl kteki d zenlemelere uygun olarak yeterince havaland r lan bir odada kullan...

Page 158: ...levinin devreye girmesine ve cihaz n kapanmas na neden olabilir Elektrik ve su ba lant lar onar m ve bak m al malar i in f r n duvardan uygun bir mesafe b rakacak ekilde yerle tirin F r n n uygun ekil...

Page 159: ...200 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201 G 26...

Page 160: ...rle tirilmelidir ek 7 YANMA TEHL KES Ha lanmay nlemek i in s t ld nda s v hale gelen yiyecek veya s v i eren kaplar kolayca g r lemeyecek y kseklikte bir yere koymay n Tepsiler orijinal aksesuar kulla...

Page 161: ...kesici ekipman n yan nda kolay eri ilebilir bir yere tak lmal d r Bu cihaz kurulum al malar onar m temizlik ve bak m i lemleri i in ekipman n ba lant s n kesmek amac yla kullan lmal d r Kilitleme eti...

Page 162: ...00V 3 50 60Hz 3x6mm T 33 8A 40A 300mA 230V 1 50 60Hz 2x10mm T 50 9A 50A 300mA C_A 062 E C_AW 062 E C_AP 0623 E C_APW 0623 E 400V 3N 50 60Hz 3x6mm2 N T 32 9A 40A 300mA 22 8 230V 3 50 60Hz 3x16mm T 57 2...

Page 163: ...h Hi G30 G31 G20 15 488 BTU h Hi G30 G31 G20 61 460 kW Hi G30 G31 G20 18 C_A 201 G C_AW 201 G C_AP 201 G C_APW 201 G 230V 1 50 60Hz 2x1 5mm T 16A ELEKTR K G C 2 75 KW GAZ G C kcal h Hi G30 G31 G20 30...

Page 164: ...kli dinamik bas n mbar Minimum bas n mbar Maksimum bas n mbar Model 061 Model 101 Model 201 Model 102 Model 202 G 20 m s Do al Gaz 20 17 25 1 270 1 905 3 809 3 704 6 878 G 30 kg s B tan 28 30 25 35 0...

Page 165: ...100165 2004 standard na uygun olarak emilmesi i in bir at k gaz davlumbaz tak lmas tavsiye edilir Davlumbaz ekipman n n k sm ndan 200 400 mm k nt yapmal d r Gazla ilgili par alar n her y l yetkili bi...

Page 166: ...yap l r Kurulumu yerel mevzuata uygun ekilde ger ekle tirin F r na yaln zca ekstraksiyon sistemi al t r ld nda gaz beslemesi yap lmas nerilir Ekstraksiyon havaland rma sisteminin ar zalanmas durumund...

Page 167: ...c maddeler yerle tirmeyin 3 9Su ba lant s Cihaz yaln zca i me suyuna ba lay n retici taraf ndan verilen yeni bir hortum tak m kullanarak belirtilen noktalardan ek 11 su ebekesine ba lant yap n Eski h...

Page 168: ...Filtre sistemleri A B C D se erken reticiye unlar tavsiye ederiz BRITA Ba lamadan nce su giri ini g steren etikete bak n Sadece ngiltere IRN R160 Kurulumu yapan ki i taraf ndan ger ekle tirilmelidir...

Page 169: ...s n rl bir s re i inde pompalama hacmi 0 7 l sn Ortalama at k su s cakl 65 C ek 13 Masa st modeller 061 101 102 Tahliye kitinin f r n k n n zerine monte edilmesi suyun f r n n yo u ma kanal na ta mas...

Page 170: ...3 Kurulum talimatlar 20 Tahliye borusu monte edildikten sonra genel tahliye sistemine bo alt lmas EN1717 standard na g re AA AB veya AD tipi olmal d r...

Page 171: ...a olanak tan yan bir i levdir Bu i lem s ras nda al ma parametreleri f r n n kurulu oldu u rak ma g re otomatik olarak ayarlan r Entegre buhar jenerat r bulunan f r nlar n do ru al mas i in nem sens r...

Page 172: ......

Page 173: ...CZ Origin ln instala n manu l P ed prvn m pou it m spot ebi e si pe liv p e t te pokyny v t to p ru ce...

Page 174: ...ny k instalaci 7 3 1 P EPRAVA A VYBALEN 7 3 2 UM ST N A VYROVN V N 8 3 3 MINIM LN VZD LENOSTI 8 3 4 HMOTNOSTI MODEL 9 3 5 USAZEN 10 3 6 ELEKTRICK P IPOJEN 11 3 7 PLYNOV P IPOJEN POUZE PLYNOV MODELY 13...

Page 175: ...e nespr vn nastaven nespr vn dr ba spot ebi e stejn jako nespr vn manipulace se spot ebi em mohou zp sobit kody na majetku a zran n Je absolutn zak z no m nit blokovat odstra ovat nebo obch zet bezpe...

Page 176: ...sti a dve n sklo mohou dosahovat velmi vysok ch teplot 60 C Otev r n dve prov d jte pomalu s ohledem na horkou p ru vych zej c z varn komory P i manipulaci s p edm ty uvnit varn komory pou vejte v dy...

Page 177: ...e t te pokyny v tomto manu lu V bl zkosti spot ebi e neskladujte ani nepou vejte v bu n plyny nebo kapaliny ani do n j nevkl dejte kapaliny obsahuj c alkohol Kdy je konvektomat hork neotev rejte dve...

Page 178: ...st edky a pom cky VAROV N P ed manipulac se spot ebi em si uv domte kde je t i t b emene Existuje riziko zran n p i ne ekan m p evr en Vybalte spot ebi a zkontrolujte zda nebyl b hem p epravy po kozen...

Page 179: ...uze na a nebo k neho lav mu povrchu Nen li uvedeno jinak s d ly kter jsou chr n ny v robcem nesm instala n technik manipulovat Riziko p du v d sledku kluzk ch podlah v m st instalace stroje 3 3 Minim...

Page 180: ...3 E 200 kg C_APW 0623 G 210 kg C_A 101 E 130 kg C_A 101 G 150 kg C_AW 101 E 140 kg C_AW 101 G 160 kg C_AP 101 E 145 kg C_AP 101 G 165 kg C_APW 101 E 150 kg C_APW 101 G 170 kg C_A 201 E 240 kg C_A 201...

Page 181: ...kl dejte plechy a gastron doby obsahuj c tekutiny nebo potraviny kter se p i zah t st vaj tekut mi do vy ch pozic kter nejsou snadno viditeln Gastron doby lze um stit do konvektomatu v maxim ln v ce 1...

Page 182: ...p stupn m m st mus b t um st n hlavn vyp na pro v echny f ze u n ho vzd lenost rozpojen ch kontakt je nejm n 3 mm Sou st elektrick instalace p ipojen ho za zen mus b t p im en dimenzovan ochrann proud...

Page 183: ...50 200 V 3 50 60 Hz 3x16 T 55 4 63 C_A 201 E C_AW 201 E C_AP 201 E C_APW 201 E 400 V 3N 50 60 Hz 3x16 N T 55 4 63 300 38 4 230 V 3 50 60 Hz 3x35 T 96 4 100 200 V 3 50 60 Hz 3x35 T 110 9 125 C_A 102 E...

Page 184: ...in ln m tepeln m zat en Druh plynu Dynamick tlak mbar Minim ln tlak mbar Maxim ln tlak mbar Modely 061 Modely 101 Modely 201 Modely 102 Modely 202 G 20 m h Zemn plyn 20 17 25 1 270 1 905 3 809 3 704 6...

Page 185: ...iv Doporu uje se instalovat ods vac digesto pro odtah zplodin v par a par v souladu s normou UNE 100165 2004 Digesto by m la vy n vat 200 400 mm p es p edn hranu konvektomatu Doporu ujeme aby komponen...

Page 186: ...v n Prove te instalaci dle m stn ch p edpis P vod plynu do konvektomatu mus b t umo n n pouze tehdy je li aktivov n ods vac syst m V p pad poruchy ods vac ho ventila n ho syst mu bude p vod plynu do k...

Page 187: ...hadic dodan ch spole n se za zen m Star hadice nesm b t znovu pou ity Konvektomat je v dy vybaven dv ma vstupn mi elektroventily Vodu je pot eba p iv st na oba Na elektroventil v cecestn ur en pro nap...

Page 188: ...Pou it sod kov ch iontom ni jak je b n v my k ch n dob se d razn nedoporu uje kv li usazenin m sod ku a zpo d n varu s b nou sol P i v b ru filtra n ch syst m A B C D doporu ujeme v robce BRITA P pojn...

Page 189: ...3 Pokyny k instalaci 18 Obr 13 Modely na podstavec 061 101 102 Pokud je odpadn syst m sifon nainstalov n p li vysoko m e doj t k zate en vody do okapov li ty pod dve mi D 70 mm Obr 14 Modely 201 a 202...

Page 190: ...3 Pokyny k instalaci 19 Jakmile je odpadn syst m sifon nainstalov n mus b t jeho vypou t n do obecn ho odtoku typu AA AB nebo AD v souladu s normou EN1717...

Page 191: ...st je funkce kter umo uje konvektomatu automaticky se p izp sobit okoln m podm nk m B hem tohoto procesu jsou automaticky p izp sobov ny provozn parametry nadmo sk v ce ve kter je konvektomat instalov...

Page 192: ...Fagor Industrial S Coop B Sancholopetegui 22 Aptdo 17 20560 O ATI SPANYA Tel 34 943 71 80 30 Faks 34 943 71 81 81 info fagorindustrial com...

Reviews: