Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
BCSD-65/116
4.4.3. Adjusting Reference Offset
Note:
Please see content of 5.2.4 and 5.2.5.
4.4.4. Soft Start
The soft start function converts the stepwise speed reference inside the servodrive to a consistent rate
of acceleration and deceleration.
Pn310 can be used to select the soft start form:
0: Slope; 1: S curve; 2: 1st-order filter; 3: 2nd-order filter
When Pn310=0 parameters Pn306 and Pn307 have not sense, the driver interpolates between two
consecutive speed references.
Pn306
Soft Start Acceleration Time
Speed
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 ~ 10000
1 ms
0
Immediately
Pn307
Soft Start Deceleration Time
Speed
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 ~ 10000
1 ms
0
Immediately
The soft start function enables smooth speed control when inputting a stepwise speed reference or when selecting
internally set speeds. Set both Pn306 and Pn307 to “0” for normal speed control.
Set these parameters as follows:
- Pn306:The time interval from the time the servomotor starts until the servomotor maximum speed is reached.
- Pn307:The time interval from the time the servomotor is operating at the servomotor maximum speed until it stops.
Summary of Contents for BCSD Series
Page 1: ...SYSTEM BCSD User manual Ref 1809...
Page 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Page 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Page 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Page 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Page 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Page 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Page 117: ......