ENGLISH
MANUAL FOR USE AND MAINTENANCE
ADVANCE PLUS
39
TYPES OF FAULT
When an error occurs:
The bell rings intermittently.
A flashing message is shown on the upper text of the display.
If the START/STOP button is pressed, the error message continues to be
displayed but the bell stops ringing.
To erase the error message and stop the bell, disconnect the controller
voltage or remove the fault causing the error.
When the fault causing the error is removed, the outputs return to normal
operation.
The errors which may occur in the oven are listed below, together with the
message displayed and the impact on the operation of the oven.
E1 Sensor TC
DESCRIPTION:
Camera probe broken. TC out of range [-5..330]
CONSEQUENCES:
The oven is completely disabled
E2 Sensor TN
DESCRIPTION:
Core probe broken. TN out of range [-10..330]
CONSEQUENCES:
The spike and delta function is disabled
E3 Sensor TV
DESCRIPTION:
Steam probe broken. TV out of range [-5..330]
CONSEQUENCES:
It is only possible to operate in
Convection
mode, omitting water
condensation.
E4 Sensor TG
DESCRIPTION:
Gas probe broken.
TG out of range [-5..330]
CONSEQUENCES:
It is only possible to operate in
Convection
mode
E5: Water Level
DESCRIPTION
Water is detected at the maximum level but not at the minimum level.
CONSEQUENCE
It is only possible to operate in
Convection
mode
E6: Calibration Error
DESCRIPTION
It was not possible to calibrate in 15 minutes.
CONSEQUENCE
The oven continues to function normally
.
E7: Error A.E.
DESCRIPTION
The variator frequency input (A.E.) has been observed not to function.
The connection has been cut off
Summary of Contents for APE 202
Page 4: ...ESPA OL MANUAL DE USO Y MANTENIMIENTO ADVANCE PLUS 4 ELEMENTOS DE MANDO Fig 1...
Page 25: ...ENGLISH MANUAL FOR USE AND MAINTENANCE ADVANCE PLUS 25 CONTROLS Fig 12...
Page 46: ...DEUTSCH BEDIENUNGS UND WARTUNGSANLEITUNG ADVANCE PLUS 46 BEDIENELEMENTE Abb 12...
Page 67: ...FRAN AIS UTILISATION ET MAINTENANCE MANUEL ADVANCE PLUS 67 L MENTS DE COMMANDE Fig 12...
Page 88: ...ITALIANO MANUALE USO E MANUTENZIONE ADVANCE PLUS 88 ELEMENTI DI COMANDO Fig 12...