Fagor AD - 21 W Service Manual Download Page 1

SERVICE

 

MANUAL

 

**********

 

2013

 

UNDERCOUNTER

 

GLASSWASHER

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

 

 

UNDERCOUNTER

 

GLASSWASHER

 

Models:

 

AD

 

 

21

 

W

 

                  
 

Summary of Contents for AD - 21 W

Page 1: ...SERVICE MANUAL 2013 UNDERCOUNTER GLASSWASHER UNDERCOUNTER GLASSWASHER Models AD 21 W...

Page 2: ...EQUESTED QUALITY OF THE WATER 7 WATER DRAINAGE INSTALLATION 7 ELECTRICAL CONNECTION 8 INSTALLATION CHECKLIST 9 OPERATION 9 TURNING THE MACHINE ON 10 PREPARING THE MACHINE 10 WASHING 10 COOL RINSE 11 D...

Page 3: ...s 15 Flow rinse pressure 20 25 psi Total Time Seconds 3 settings 60 90 180 Wash Pump Motor Dimensions Shipping Motor hp 1 3 HP Width 20 508 mm Depth 24 1 2 622 mm Temperatures Height 34 1 2 876 mm Was...

Page 4: ...amage should be noted and reported to the delivering carrier immediately If damaged open and inspect the contents with the carrier In the event that the exterior is not damaged yet upon opening there...

Page 5: ...maintenance personnel It is recommended that in the event the data plate is removed you copy down the essential information in this manual for reference before installation Any transformations or chan...

Page 6: ...noid valve is opened during the cycle THE DISPLAY OF THE PRESSURE GAUGE SHALL BE CLEARLY VISIBLE OF THE OPERATOR OF THE MACHINE THE GAUGE SHALL HAVE INCREMENTS OF 1 psi 7 kpa OR SMALLER AND SHALL BE A...

Page 7: ...the machine Adaptor supplied for female garden hose connection FOR HARD WATER SUPPLIES WITH A HARDNESS OF OVER 2 GRAINS OR 10 F AND PH BEYOND THE RANGE OF 7 0 8 5 A WATER CONDITIONER MUST BE INSTALLED...

Page 8: ...d from the rear to facilitate cleaning of the location of the glass washer Install a circuit breaker according to required consumption guidelines Page 1 and data plate The machine must be grounded Fig...

Page 9: ...__ F Is the water hardness 2 0gpg 34 2ppm and PH level 7 8 5ph Has the drain plumbing been installed according to the instructions in this manual Height of the drain hose ______ Air gap size _______ W...

Page 10: ...ures are displayed before putting the machine to wash WASHING NOTE All models are fitted with Thermo stop The temperature of the incoming water should be higher than 120 F 50 C Ideal temp 140 F 60 C I...

Page 11: ...it should be drained after each meal rush Draining the Machine Open the door and remove the Front Right S S Filter leave door open Fig 8 Remove the overflow tube by inserting a finger into the top of...

Page 12: ...ed Detergent and place inside detergent container Take the tube with a blue stripe mark and place inside rinse container Tubes are clear to provide you a visible means that chemicals are being dispens...

Page 13: ...de down Put cutlery in the cutlery baskets handles down Mix spoons with knives and forks Fig 10 Put the special cutlery baskets in the base baskets Fig 10 Fig 11 DELIMING In order to maintain dishwash...

Page 14: ...e at terminal 2 brown and GND If no voltage P1 is possible stuck Faulty rinse fill valve V Verify the wiring and proper voltage at valve if correct replace fill valve Dishwasher will NOT RUN after the...

Page 15: ...ax 25 psi Clogged or obstructed rinse arms Remove and clean rinse arms nozzles Dishwasher FILLS slowly and or rinse is weak Poor water pressure Verify the inlet water pressure is at a min of 20 psi an...

Page 16: ...or damaged replace pressure switch P2 Machine temperatures or pressure may not be to specification Wait until sanitized rinsing temperature reached a min of 180 F Check out your incoming water temper...

Page 17: ...ile the drainage pump does not drain the water in the tank to the correct level in the specified time 4 Flashes BOILER HEATING ERROR This is indicated by a four flashes and a pause This continues whil...

Page 18: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 18 ELECTRICAL DIAGRAM...

Page 19: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 19 WIRING SCHEMATIC...

Page 20: ...V 16A 50 60 HZ Z393005 Boiler thermostat Z400709 Washing nozzle Z400711 Washing nozzle bracket Z401001 Pump motor 60Hz Z421711 Boiler heating element 2800W Z433011 Pressure switch Z393005 Tank thermos...

Page 21: ...between 25 and 2 0 grains per gallon pH level between 7 0 8 5 and TDS level at 250 PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation...

Page 22: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 22 Fagor Commercial Inc 13105 NW 47th Ave Miami Fl 33054 Tel 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...

Reviews: