background image

5CFB-90X and 5CFB-60X 

WALL CANOPY 

5CFB

5CFB

-

-

90X and 5CFB

90X and 5CFB

-

-

60X 

60X 

WALL CANOPY

WALL CANOPY

Installation and Operation Manual 

Summary of Contents for 5CFB-60X

Page 1: ...5CFB 90X and 5CFB 60X WALL CANOPY 5CFB 5CFB 90X and 5CFB 90X and 5CFB 60X 60X WALL CANOPY WALL CANOPY Installation and Operation Manual ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ... category III conditions in accordance with the wiring rules Attention substituting the supply cable must be carried out by the authorised technical assistance service Mounting Expansion wall plugs are provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling The wall ceiling must ...

Page 11: ...nent mounting Fig 11 11 Remove the hood from the lower bracket 12 Drill at the point marked Ø8mm Fig 12 13 Insert 1 or 2 wall screw anchors according to requirement 14 Apply the flues support bracket G to the wall adherent to the ceiling use the flues support bracket as a perforation diagram if present the small slot on the support must coincide with the line drawn previously on the wall and mark ...

Page 12: ... cleaned press button 1 for about 3 seconds until you hear the acoustic signal beep the LED 4 will now stop flashing 5 Speed 3 LED and active carbon filter saturation LED in this latter case the LED will flash See instructions on active carbon filter replacement Once you have replaced the charcoal filter press button 1 for about 3 seconds until you hear the acoustic signal beep LED 5 will now stop...

Page 13: ... more before contacting the Technical Assistance Service Warning Always press the fan off button A before disconnecting the hood from the mains supply Functioning Model with display A B C D E F A Lighting on off B Fan off Stand by C Timer for selected speed visualizes the speed selected and flashing LED on the lower side of the display This knob permits the operation of the cooker hood for a estab...

Page 14: ... seconds A beep signals each time the operation is completed Enabling the carbon filter signal the hood is enabled only for the fats filter signal To enable the carbon filter signal hood in Off press keys T2 and T4 for 3 seconds The flashing of Leds 1 and 2 signals the completion of the setting To disenable the carbon filter signal repeat this operation again always with the hood in Off A beep sig...

Page 15: ... tool 2 Replace the damaged light bulb Only use halogen bulbs of 20W max G4 making sure you do not touch them with your hands 3 Close the lamp cover it will snap shut For models shown in Fig 1J Fig 4J 1 Use a small screwdriver as a lever on the borders of the lamp in order to remove the lightbulb 2 Unthread the connector a 3 Slide out the lightbulb to be replaced and replace with a new 12V 20W 30 ...

Page 16: ...ty measures to adopt for discharging fumes are concerned The hood is to be cleaned frequently both internally and externally Failure to observe the regulations about cleaning the hood and substituting and cleaning the filters can lead to the risk of fire Any responsibility is declined for possible inconveniences damage or fire caused to the apparatus deriving from failure to observe the instructio...