3.4
Technical Data
Interface sensors
SEPARIX-C L Plus
Ex marking:
II 1 G Ex ia IIB T4 Ga
Certificate
TÜV 03 ATEX 2368 X
Protection class
IP68
Dimensions
28 mm x 195 mm
Cable length
5.0 m
Ambient temperature
-20 °C … +70 °C
-20 °C … +60 °C (explosion-risk area)
Medium temperature
0 °C … +70 °C
0 °C … +60 °C (explosion-risk area)
Connection data
Voltage:
Current:
Power:
Capacitance (externally effective):
Inductance (externally effective):
U
i
≤
15 V
I
i
≤
30 mA
P
i
≤
100 mW
C
i
≤
10 nF
L
i
≤
100 µH
High-level sensors
SEPARIX-T L Plus
Ex marking:
II 1 G Ex ia IIC T4 Ga
II 1/2 G Ex ia IIC T4 Ga/Gb
Certificate
TÜV 00 ATEX 1656 X
Protection class
IP68
Dimensions
16 mm x 278 mm
Cable length
5 m
Ambient temperature
-25°C … +60 °C
Medium temperature
-25°C … +50 °C
Connection data
Voltage:
Current:
Power:
Capacitance (externally effective):
Inductance (externally effective):
U
i
≤
30 V
I
i
≤
200 mA
P
i
≤
1 W
C
i
negligibly small
L
i
negligibly small